Determination of trace amount of bismuth(III) by adsorptive anodic stripping voltammetry at carbon paste electrode

被引:50
|
作者
Guo, HS
Li, YH
Xiao, PF
He, NY [1 ]
机构
[1] SE Univ, Minist Educ, Key Lab Mol & Biomol Elect, Nanjing 210096, Peoples R China
[2] Xiangtan Univ, Dept Chem, Xiangtan 411105, Peoples R China
基金
中国国家自然科学基金;
关键词
adsorptive voltammetry; carbon paste electrode; bismuth; bromopyrogallol red;
D O I
10.1016/j.aca.2004.04.020
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive method is described for the determination of trace bismuth based on the bismuth-bromopyrogallol red (BPR) adsorption at a carbon paste electrode (CPE). The overall analysis involved a three-step procedure: accumulation, reduction, and anodic stripping. Optimal conditions were found to be an electrode containing 25% paraffin oil and 75% high purity graphite powder, a 0.30 mol l(-1) HCl solution containing 2.0 x 10(-5) mol l(-1) BPR as supporting medium; accumulation potential and time, -0.10 V, 3 min; reduction potential and time, -0.35 V, 60 s; scan rate 100 mV s(-1); scan range from -0.35 to 0.15 V. It was found that the Bi(III)-BPR complex could be accumulated on the electrode surface during the accumulation period. Then the Bi(III) in the Bi(III)-BPR complex on the CPE surface was reduced to Bi(0) during reduction interval and finally reoxidized during the anodic stripping step for voltammetric quantification. Factors affecting the accumulation, reduction, and stripping steps were investigated. Interferences by other ions were studied as well. The detection limit was found to be 5 x 10(-10) mol l(-1) with a 3 min accumulation time. The linear range was from 1.0 x 10(-9) to 5.0 x 10(-7) mol l(-1). Application of the procedure to the determination of bismuth in water and human hair samples gave good results. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:143 / 147
页数:5
相关论文
共 50 条
  • [1] Anodic adsorptive stripping voltammetry at a carbon paste electrode for determination of trace thorium
    Liu, SM
    Li, JN
    Mao, X
    Gao, P
    [J]. ANALYTICAL LETTERS, 2003, 36 (07) : 1381 - 1392
  • [2] Determination of trace bismuth by adsorptive stripping voltammetry with pyrogallol red modified carbon paste electrode
    Guo, HS
    Li, YH
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 28 (12) : 1527 - 1530
  • [3] Determination of trace vanadium by adsorptive stripping voltammetry at a carbon paste electrode
    Li, Yi-Heng
    Wang, Yue-Xuan
    Huang, Mei-Hua
    [J]. ELECTROANALYSIS, 2008, 20 (13) : 1440 - 1444
  • [5] Determination of trace tin by anodic stripping voltammetry at a carbon paste electrode
    Li, Yi-Heng
    Xie, Hong-Qi
    Zhou, Fang-Qin
    Guo, Hui-Shi
    [J]. ELECTROANALYSIS, 2006, 18 (10) : 976 - 980
  • [6] Determination of Trace Bismuth(III) by Stripping Voltammetry at Antimony-Coated Carbon Paste Electrode
    Ashrafi, Amir M.
    Vytras, Karel
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (01): : 68 - 76
  • [7] Determination of trace amount of bismuth(III) by adsorptive stripping voltammetry by alizarine red S
    Shams, E
    [J]. ELECTROANALYSIS, 2001, 13 (13) : 1140 - 1142
  • [8] Trace determination of zirconium(IV) by anodic adsorptive voltammetry at a carbon paste electrode
    Mao, X
    Lai, HX
    Li, JN
    Gao, P
    Yan, ZH
    [J]. CHINESE CHEMICAL LETTERS, 2004, 15 (11) : 1315 - 1318
  • [9] Determination of trace lead by adsorptive stripping voltammetry at quercetin modified carbon paste electrode
    Fei, JJ
    Li, JN
    Yi, FY
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 29 (08) : 916 - 918
  • [10] Trace determination of vardenafil hydrochloride in commercial formulation and human serum by adsorptive anodic stripping voltammetry at a carbon paste electrode
    Mohamed M. Ghoneim
    Amera M. Hassanein
    Nehal A. Salahuddin
    Hanaa S. El-Desoky
    Mona N. Elfiky
    [J]. Journal of Solid State Electrochemistry, 2013, 17 : 1891 - 1902