Sensitive and Rapid UHPLC-MS/MS for the Analysis of Tomato Phenolics in Human Biological Samples

被引:12
|
作者
Martinez-Huelamo, Miriam [1 ,2 ]
Tulipani, Sara [3 ]
Jauregui, Olga [4 ]
Valderas-Martinez, Palmira [2 ,5 ]
Vallverdu-Queralt, Anna [2 ,6 ]
Estruch, Ramon [2 ,5 ]
Torrado, Xavier [1 ]
Lamuela-Raventos, Rosa M. [1 ,2 ]
机构
[1] Univ Barcelona, Dept Nutr & Food Sci XARTA INSA, Sch Pharm, E-08028 Barcelona, Spain
[2] Carlos III Hlth Inst, Ctr Biomed Network Res Pathophysiol Obes & Nutr C, Madrid 28029, Spain
[3] Univ Malaga, Hosp Virgen Victoria, Biomed Res Inst IBIMA, Serv Endocrinol & Nutr, Malaga 29010, Spain
[4] Univ Barcelona CCiTUB, Ctr Sci & Technol, Barcelona 08028, Spain
[5] Univ Barcelona, Dept Internal Med, Hosp Clin, Inst Biomed Invest August Pi I Sunyer IDIBAPS, E-08028 Barcelona, Spain
[6] INRA, Sci Oenol UMR1083, F-34060 Montpellier, France
关键词
polyphenol metabolites; validation; tomato; sauce; microbiota; metabolites; biosamples; blood; urine; PERFORMANCE LIQUID-CHROMATOGRAPHY; POLYPHENOL-RICH FOODS; MASS-SPECTROMETRY; CAPILLARY-ELECTROPHORESIS; BIOACTIVE COMPOUNDS; URINARY-EXCRETION; UPLC; METABOLITES; VALIDATION; ACIDS;
D O I
10.3390/molecules201119702
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
An UHPLC-MS/MS method for the quantification of tomato phenolic metabolites in human fluids was optimized and validated, and then applied in a pilot dietary intervention study with healthy volunteers. A 5-fold gain in speed (3.5 min of total run); 7-fold increase in MS sensitivity and 2-fold greater efficiency (50% peak width reduction) were observed when comparing the proposed method with the reference-quality HPLC-MS/MS system, whose assay performance has been previously documented. The UHPLC-MS/MS method led to an overall improvement in the limits of detection (LOD) and quantification (LOQ) for all the phenolic compounds studied. The recoveries ranged between 68% and 100% in urine and 61% and 100% in plasma. The accuracy; intra- and interday precision; and stability met with the acceptance criteria of the AOAC International norms. Due to the improvements in the analytical method; the total phenolic metabolites detected in plasma and urine in the pilot intervention study were 3 times higher than those detected by HPLC-MS/MS. Comparing with traditional methods; which require longer time of analysis; the methodology described is suitable for the analysis of phenolic compounds in a large number of plasma and urine samples in a reduced time frame.
引用
收藏
页码:20409 / 20425
页数:17
相关论文
共 50 条
  • [41] Evaluation of superficially porous and fully porous columns for analysis of drugs in plasma samples by UHPLC-MS/MS
    Acquaro Junior, Vinicius Ricardo
    Lancas, Fernando Mauro
    Costa Queiroz, Maria Eugenia
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1048 : 1 - 9
  • [42] A UHPLC-MS/MS method for profiling multifunctional steroids in human hair
    Zhen Dong
    Caihong Wang
    Jinlan Zhang
    Zhe Wang
    [J]. Analytical and Bioanalytical Chemistry, 2017, 409 : 4751 - 4769
  • [43] The development and validation of an UHPLC-MS/MS method for the rapid quantification of the antiretroviral agent dapivirine in human plasma
    Seserko, Lauren A.
    Emory, Joshua F.
    Hendrix, Craig W.
    Marzinke, Mark A.
    [J]. BIOANALYSIS, 2013, 5 (22) : 2771 - 2783
  • [44] A UHPLC-MS/MS method for profiling multifunctional steroids in human hair
    Dong, Zhen
    Wang, Caihong
    Zhang, Jinlan
    Wang, Zhe
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2017, 409 (20) : 4751 - 4769
  • [45] Determination of Tyrosine Kinase Inhibitors in Human Plasma by UHPLC-MS/MS
    Micova, Katerina
    Friedecky, David
    Polynkova, Adriana
    Faber, Edgar
    Adam, Tomas
    [J]. CHEMICKE LISTY, 2010, 104 : S31 - S34
  • [46] Polar stir bars for isolation and preconcentration of perfluoroalkyl substances from human milk samples prior to UHPLC-MS/MS analysis
    Martin, Julia
    Rodriguez-Gomez, Rocio
    Zafra-Gomez, Alberto
    Alonso, Esteban
    Vilchez, Jose L.
    Navalon, Alberto
    [J]. BIOANALYSIS, 2016, 8 (07) : 633 - 647
  • [47] Dilution of QuEChERS Extracts Without Cleanup Improves Results in the UHPLC-MS/MS Multiresidue Analysis of Pesticides in Tomato
    Stringhini, Fabiane M.
    Ribeiro, Lucila C.
    Rocha, Graziela I.
    Kuntz, Juliana D. de B.
    Zanella, Renato
    Prestes, Osmar D.
    Adaime, Martha B.
    [J]. FOOD ANALYTICAL METHODS, 2021, 14 (08) : 1511 - 1523
  • [48] Dilution of QuEChERS Extracts Without Cleanup Improves Results in the UHPLC-MS/MS Multiresidue Analysis of Pesticides in Tomato
    Fabiane M. Stringhini
    Lucila C. Ribeiro
    Graziela I. Rocha
    Juliana D. de B. Kuntz
    Renato Zanella
    Osmar D. Prestes
    Martha B. Adaime
    [J]. Food Analytical Methods, 2021, 14 : 1511 - 1523
  • [49] Rapid Quantitative Analysis of 19 Bioactive Components in Fangji Huangqi Decoction Based on UHPLC-MS/MS
    Cui, Wenbo
    Yang, Liu
    Zhang, Lichao
    Liu, Yuetao
    Yan, Yan
    Li, Aiping
    Qin, Xuemei
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2023, 61 (09) : 852 - 862
  • [50] Quantitative analysis of pseudoephedrine tablets by UHPLC-MS
    Jiang, Guifeng
    Chen, Ray
    Loran, Chris
    [J]. LC GC NORTH AMERICA, 2008, : 67 - 67