Typical indoor concentrations and emission rates of particulate matter at building level: A case study to setup a measuring strategy for pig fattening facilities

被引:18
|
作者
Van Ransbeeck, Nele [1 ]
Van Langenhoue, Herman [2 ]
Van Weyenberg, Stephanie [1 ]
Maes, Dominiek [3 ]
Demeyer, Peter [1 ]
机构
[1] Inst Agr & Fisheries Res ILVO, Dept Agr Engn, Technol & Food Sci Unit, Merelbeke, Belgium
[2] Univ Ghent, Fac Biosci Engn, Dept Sustainable Organ Chem & Technol, Ghent, Belgium
[3] Univ Ghent, Fac Vet Med, Dept Obstet Reprod & Herd Hlth, Ghent, Belgium
关键词
LIVESTOCK BUILDINGS; DUST CONCENTRATION; NORTHERN EUROPE; HOUSES; MODEL;
D O I
10.1016/j.biosystemseng.2011.12.004
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
The objective was to collect a large dataset on both indoor concentrations and emission rates of particulate matter (PM), make a detailed analysis of the temporal and spatial variations of PM, and thereby develop a measuring strategy for pig fattening facilities. Different PM fractions ranging from 0.25 to 32 mu m were sampled continuously together with environmental parameters (i.e., temperature and relative humidity). Sampling position (19 locations) within the compartment showed a significant effect on PM concentration, but this was small compared to the effect of the daily variations and the variation over the whole fattening period. The contribution of location to the variance of indoor PM concentrations was 6, 4 and 12% for PM1, PM2.5 and PM10, respectively. The effect of daily variation contributed 29, 65 and 58% to the concentration variance, while the effect of variation over the fattening period was 65, 31 and 31% for PM1, PM2.5 and PM10, respectively. Based on these conclusions, a measuring strategy for pig fattening facilities is proposed. For one fattening period, the strategy consists of 4 to 5 specific sampling periods of 48 h. This measuring strategy offers the possibility to shorten the total sampling time significantly and to reduce the number of measurements without loss of important PM concentration characteristics (e.g., daily peak concentrations and emission factors). This strategy also allows a reconstruction of the evolution of PM concentrations over the entire fattening period. (C) 2011 IAgrE. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:280 / 289
页数:10
相关论文
共 11 条
  • [1] Indoor concentrations and emissions factors of particulate matter, ammonia and greenhouse gases for pig fattening facilities
    Van Ransbeeck, Nele
    Van Langenhove, Herman
    Demeyer, Peter
    BIOSYSTEMS ENGINEERING, 2013, 116 (04) : 518 - 528
  • [2] Indoor and Outdoor Concentrations of Particulate Matter and Gaseous Pollutants on Different Floors of a University Building: A Case Study
    Cichowicz, Robert
    Dobrzanski, Maciej
    JOURNAL OF ECOLOGICAL ENGINEERING, 2021, 22 (01): : 162 - 173
  • [3] Indoor concentration measurements of particulate matter at a pig fattening facility: Comparison and equivalence tests with different sampling instruments and measuring techniques
    Van Ransbeeck, Nele
    Van Weyenberg, Stephanie
    Van Langenhove, Herman
    Demeyer, Peter
    BIOSYSTEMS ENGINEERING, 2013, 115 (04) : 453 - 462
  • [4] Vertical Profile of Particulate Matter Concentrations in Indoor Air (Case Study: Karaj, Iran)
    Halek, Farah
    PARTICULATE SCIENCE AND TECHNOLOGY, 2015, 33 (06) : 617 - 620
  • [5] A PRELIMINARY STUDY OF THE CONCENTRATIONS AND MASS SIZE DISTRIBUTIONS OF PARTICULATE MATTER IN INDOOR SPORTS FACILITIES BEFORE AND DURING ATHLETE TRAINING
    Kuskowska, Karolina
    Rogula-Kozlowska, Wioletta
    Widziewicz, Kamila
    ENVIRONMENT PROTECTION ENGINEERING, 2019, 45 (03): : 103 - 112
  • [6] Variation of Indoor Particulate Matter Concentrations and Association with Indoor/Outdoor Temperature: A Case Study in Rural Limpopo, South Africa
    Kapwata, Thandi
    Language, Brigitte
    Piketh, Stuart
    Wright, Caradee Y.
    ATMOSPHERE, 2018, 9 (04):
  • [7] Measuring indoor particulate matter concentrations and size distributions at different time periods to identify potential sources in an office building in Taipei City
    Cheng, Yu-Hsiang
    BUILDING AND ENVIRONMENT, 2017, 123 : 446 - 457
  • [8] Indoor and Outdoor Concentrations of Particulate Matter in an Airport Terminal Building: A Pilot Study at Soekarno-Hatta International Airport in Indonesia
    Kim, Amy
    Medal, Lysandra
    Wang, Shuoqi
    Larson, Timothy
    BUILDINGS, 2020, 10 (02)
  • [9] Reduction of particulate matter concentrations by local removal in a building courtyard: Case study for the Delhi American Embassy School
    Vervoort, R.
    Blocken, B.
    van Hooff, T.
    SCIENCE OF THE TOTAL ENVIRONMENT, 2019, 686 : 657 - 680
  • [10] Ventilation strategy for simultaneous management of indoor particulate matter and airborne transmission risks-A case study for urban schools in South Korea
    Koo, Junemo
    Jo, Young Min
    Lee, Tae Jeong
    Park, Sowoo
    Song, Doosam
    BUILDING AND ENVIRONMENT, 2023, 242