ITER nuclear fusion experiment requires additional heating via neutral beams by means of two injectors, delivering 16.5 MW each, up to one hour. This power level results from the neutralization of negative deuterium ions generated by an RF source and accelerated to 1 MeV. Such specifications have never been simultaneously achieved so far and therefore a test facility is being constructed at Consorzio RFX, to demonstrate the feasibility of a prototype neutral beam injector. The facility will host two experimental devices: SPIDER, a 100 kV negative hydrogen/deuterium RF source, full size prototype of the ITER source, and MITICA, a prototype of the full ITER injector. SPIDER will be devoted to optimize the extracted negative ion current density and its spatial uniformity and to minimize the co-extracted electron current. Negative hydrogen is mainly produced by conversion of hydrogen particles at the cesium coated surface of the plasma grid. The interplay of these two species is fundamental to understand and optimize the source performance. Two laser-aided diagnostics play an important role in measuring the negative hydrogen and cesium density: cavity ring down spectroscopy and laser absorption spectroscopy. Cavity ring down spectroscopy will use the photo-detachment process to measure the absolute line-of-sight integrated negative ion density in the extraction region of the source. Laser absorption spectroscopy will be employed to measure the line integrated neutral cesium density, allowing to study the cesium distribution in the source volume, during both the plasma and the vacuum phases. In this paper, the design of the laser-aided diagnostic systems on SPIDER is presented, supported by a review of results obtained in other operating experiments.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] NEGATIVE HYDROGEN ION SOURCE
    WEINMAN, JA
    CAMERON, JR
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1956, 27 (05): : 288 - 293
  • [22] NEGATIVE HYDROGEN ION SOURCE
    PHILLIPS, JA
    TUCK, JL
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1956, 27 (02): : 97 - 98
  • [23] VUV Emission Spectroscopy Diagnostics of a 14 GHz ECR Negative Hydrogen Ion Source
    Tamura, R.
    Ichikawa, T.
    Kasuya, T.
    Nishiura, M.
    Shimozuma, T.
    Wada, M.
    FOURTH INTERNATIONAL SYMPOSIUM ON NEGATIVE IONS, BEAMS AND SOURCES (NIBS 2014), 2015, 1655
  • [24] Measurement of stripping losses in the negative ion source SPIDER
    Agnello, R.
    Barbisan, M.
    Pasqualotto, R.
    Pimazzoni, A.
    Poggi, C.
    Sartori, E.
    Serianni, G.
    FUSION ENGINEERING AND DESIGN, 2023, 186
  • [25] First operations with caesium of the negative ion source SPIDER
    Sartori, E.
    Agostini, M.
    Barbisan, M.
    Bigi, M.
    Boldrin, M.
    Brombin, M.
    Casagrande, R.
    Dal Bello, S.
    Dan, M.
    Duteil, B. P.
    Fadone, M.
    Grando, L.
    Maistrello, A.
    Pavei, M.
    Pimazzoni, A.
    Poggi, C.
    Rizzolo, A.
    Shepherd, A.
    Ugoletti, M.
    Veltri, P.
    Zaniol, B.
    Agnello, R.
    Agostinetti, P.
    Antoni, V.
    Aprile, D.
    Candeloro, V.
    Cavallini, C.
    Cavazzana, R.
    Cavenago, M.
    Chitarin, G.
    Cristofaro, S.
    Dalla Palma, M.
    Delogu, R.
    De Muri, M.
    Denizeau, S.
    Fellin, F.
    Ferro, A.
    Gasparrini, C.
    Jain, P.
    Luchetta, A.
    Manduchi, G.
    Marconato, N.
    Marcuzzi, D.
    Mario, I.
    Milazzo, R.
    Pasqualotto, R.
    Patton, T.
    Pilan, N.
    Recchia, M.
    Rigoni-Garola, A.
    NUCLEAR FUSION, 2022, 62 (08)
  • [26] Photodetachment diagnostics of a volume production type negative ion source with a diode-laser
    Matsuda, Y.
    Kasuya, T.
    Takahashi, H.
    Wada, M.
    Nishiura, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (02):
  • [27] Laser absorption spectroscopy studies to characterize Cs oven performances for the negative ion source SPIDER
    Barbisan, M.
    Cristofaro, S.
    Zampieri, L.
    Pasqualotto, R.
    Rizzolo, A.
    JOURNAL OF INSTRUMENTATION, 2019, 14
  • [28] Negative ion density in the ion source SPIDER in Cs free conditions
    Barbisan, M.
    Agnello, R.
    Casati, G.
    Pasqualotto, R.
    Poggi, C.
    Sartori, E.
    Spolaore, M.
    Serianni, G.
    PLASMA PHYSICS AND CONTROLLED FUSION, 2022, 64 (06)
  • [29] An advanced negative hydrogen ion source
    Goncharov, Alexey A.
    Dobrovolsky, Andrey N.
    Goretskii, Victor P.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2016, 87 (02):
  • [30] NEGATIVE HYDROGEN-ION SOURCE
    SEIDL, M
    PARGELLIS, AN
    GREER, J
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1979, 24 (08): : 1000 - 1000