Rapid Immunochemical Methods for Anatoxin-a Monitoring in Environmental Water Samples

被引:6
|
作者
Cevallos-Cedeno, Ramon E. [1 ,2 ]
Quinones-Reyes, Guillermo [3 ,4 ]
Agullo, Consuelo [3 ]
Abad-Somovilla, Antonio [3 ]
Abad-Fuentes, Antonio [1 ]
Mercader, Josep, V [1 ]
机构
[1] Spanish Sci Res Council CSIC, Inst Agr Chem & Food Technol IATA, Valencia 46980, Spain
[2] Tech Univ Manabi UTM, Dept Chem Proc, Av Jose Maria Urbina & Che Guevara, Portoviejo 130105, Ecuador
[3] Univ Valencia, Dept Organ Chem, E-46100 Valencia, Spain
[4] Autonomous Univ Zacatecas, Zacatecas, Zacatecas, Mexico
关键词
MONOCLONAL-ANTIBODIES; PUBLIC-HEALTH; TOXIN; CYANOBACTERIA; ACCUMULATION; LAKES; MICROCYSTINS; MARINE;
D O I
10.1021/acs.analchem.2c01939
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Algal blooms that contaminate freshwater resources with cyanotoxins constitute, nowadays, a global concern. To deal with this problem, a variety of analytical methods, including immuno-chemical assays, are available for the main algal toxins, for example, microcystins, nodularins, and saxitoxins, with the remarkable exception of anatoxin-a. Now, for the first time, highly sensitive, enantioselective immunoassays for anatoxin-a have been validated using homemade monoclonal antibodies. Two competitive enzyme-linked immunosorbent assays were developed in different formats, with detection limits for (+)-anatoxin-a of 0.1 ng/mL. Excellent recovery values between 82 and 117%, and coefficients of variation below 20%, were observed using environmental water samples fortified between 0.5 and 500 ng/mL. In addition, a lateral-flow immunochromatographic assay was optimized for visual and instrumental reading of results. This test showed a visual detection limit for (+)-anatoxin-a of 4 ng/mL. Performance with a reader was validated in accordance with the European guidelines for semiquantitative rapid methods for small chemical contaminants. Thus, at a screening target concentration of 2 ng/mL, the probability of a blank sample to be classified as "suspect" was as low as 0.2%. Finally, the optimized direct enzyme immunoassay was validated by comparison with high-performance liquid chromatography-tandem mass spectroscopy data and showed a good correlation (r = 0.995) with a slope of 0.94. Moreover, environmental water samples containing more than 2 ng/mL of anatoxin-a were detected by the developed dipstick assay. These results provide supplementary and complementary strategies for monitoring the presence of anatoxin-a in water.
引用
收藏
页码:10857 / 10864
页数:8
相关论文
共 50 条
  • [31] Rapid detection methods for Bacillus anthracis in environmental samples: a review
    Léonid M. Irenge
    Jean-Luc Gala
    Applied Microbiology and Biotechnology, 2012, 93 : 1411 - 1422
  • [32] Rapid detection methods for Bacillus anthracis in environmental samples: a review
    Irenge, Leonid M.
    Gala, Jean-Luc
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2012, 93 (04) : 1411 - 1422
  • [33] Methods for detection of anatoxin-a(s) by liquid chromatography coupled to electrospray ionization-tandem mass spectrometry
    Doerr, Felipe Augusto
    Rodriguez, Vania
    Molica, Renato
    Henriksen, Peter
    Krock, Bernd
    Pinto, Ernani
    TOXICON, 2010, 55 (01) : 92 - 99
  • [34] Immunochemical detection of nonylphenol in water samples
    Piven, N.
    Burakovski, A.
    Lukhverchyk, L.
    ALLERGY, 2011, 66 : 534 - 534
  • [35] Anatoxin-a Synthetase Gene Cluster of the Cyanobacterium Anabaena sp Strain 37 and Molecular Methods To Detect Potential Producers
    Rantala-Ylinen, Anne
    Kana, Suvi
    Wang, Hao
    Rouhiainen, Leo
    Wahlsten, Matti
    Rizzi, Ermanno
    Berg, Katri
    Gugger, Muriel
    Sivonen, Kaarina
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2011, 77 (20) : 7271 - 7278
  • [36] Occurrence of anatoxin-a(s) during a bloom of Anabaena crassa in a water-supply reservoir in southern Brazil
    Becker, Vanessa
    Ihara, Priscila
    Yunes, Joao Sarkis
    Huszar, Vera Lucia M.
    JOURNAL OF APPLIED PHYCOLOGY, 2010, 22 (03) : 235 - 241
  • [37] IMMUNOCHEMICAL METHODS - FOR ENVIRONMENTAL-ANALYSIS
    VANEMON, JM
    LOPEZAVILA, V
    ANALYTICAL CHEMISTRY, 1992, 64 (02) : A79 - A88
  • [38] Method for rapid tritiated water extraction from environmental samples
    R. Failor
    L. Belovodsky
    V. Gaevoy
    A. Golubev
    Journal of Radioanalytical and Nuclear Chemistry, 1998, 235 : 201 - 206
  • [39] Method for rapid tritiated water extraction from environmental samples
    Failor, R
    Belovodsky, L
    Gaevoy, V
    Golubev, A
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1998, 235 (1-2) : 201 - 206
  • [40] The application of immunochemical methods in monitoring and early warning systems for water quality control
    Meulenberg, E
    Stoks, P
    IWSA SPECIALIZED CONFERENCE - NEW DEVELOPMENTS IN MODELLING, MONITORING AND CONTROL OF WATER SUPPLY SYSTEMS, 1997, 15 (02): : 91 - 108