Process control procedures to augment quality control of leukocyte-reduced red cell blood products

被引:0
|
作者
Finch, SJ [1 ]
Chen, JB
Chen, CH
Hall, MM
Matkovich, V
Wenz, B
Brandwein, H
Whitbread, J
机构
[1] SUNY Stony Brook, Dept Appl Math & Stat, Stony Brook, NY 11794 USA
[2] Pall Corp, Dept Sci, Port Washington, NY 11050 USA
[3] Pall Corp, Lab Serv, Port Washington, NY 11050 USA
关键词
D O I
10.1002/(SICI)1097-0258(19990530)18:10<1279::AID-SIM112>3.0.CO;2-6
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Quality control of leukocyte-reduced packed red cell units (LRprc) produced in blood facilities must conform to regulatory criteria, which state that units may not contain more than 1 X 10(6) to 5 X 10(6) white blood cells (WBC) per unit. The post-filtration WBC content of a total of n = 386 LRprc units was counted with a Nageotte chamber to model the probability that a unit would not meet the regulatory criteria. The distribution of the residual leukocyte counts is close to a negative binomial distribution (NBD) and is independent of the packed red cell volume filtered. The observed probability that a unit of blood has a residual WBC greater than 5 X 10(6) is 2.6 +/- 2.6 X 10(-3). A power analysis of the two-sample Kolmogorov-Smirnov (KS) test in this application shows that a sample size of 20 is sufficient for determining that the process is in control when an out of control process has a k NBD parameter greater than or equal to that of the in control process. The three out of control processes observed to date appear to have this property. A sample of size 80 may be necessary for confirming that process validation data sets conform to the larger 'reference' database (n = 386) for processes that are out of control in such a way that their k NBD parameter is less than the k parameter of the in control process. Copyright (C) 1999 John Wiley & Sons, Ltd.
引用
收藏
页码:1279 / 1289
页数:11
相关论文
共 50 条
  • [41] QUALITY CONTROL OF RED BLOOD CELL COMPONENTS IN THE PERIOD 2005-2007
    Urlep-Salinovic, Veronika
    Perbil-Lazic, Katja
    Lokar, Lidija
    ZDRAVNISKI VESTNIK-SLOVENIAN MEDICAL JOURNAL, 2008, 77 : I171 - I176
  • [42] In vitro quality control of red blood cell concentrates outdated in clinical practice
    Zimmermann, R
    Heidenreich, D
    Weisbach, V
    Zingsem, E
    Neidhardt, B
    Eckstein, R
    TRANSFUSION CLINIQUE ET BIOLOGIQUE, 2003, 10 (04) : 275 - 283
  • [43] Leukocyte counting during process control of leukoreduced blood components
    Dzik, WH
    VOX SANGUINIS, 2000, 78 : 223 - 226
  • [44] A new blood bag system for the preparation of prestorage leukocyte-reduced (LR) CPDA-1 red cell concentrates (RCC) from 500mL whole blood (WB)
    Chong, C
    Chen, J
    Cortus, MA
    Carmen, R
    TRANSFUSION, 1996, 36 (09) : S58 - S58
  • [45] Extended storage of leukocyte-reduced red cells (LR-RCC) from whole blood (WB) by Leukotrap(R) filter system
    Cortus, MA
    Chong, C
    Chen, J
    Carmen, R
    TRANSFUSION, 1996, 36 (09) : S37 - S37
  • [46] CONTROL OF GLYCOLYSIS IN HUMAN RED BLOOD CELL
    ROSE, IA
    WARMS, JVB
    JOURNAL OF BIOLOGICAL CHEMISTRY, 1966, 241 (21) : 4848 - &
  • [47] Control of red blood cell mass in spaceflight
    Alfrey, CP
    Udden, MM
    LeachHuntoon, C
    Driscoll, T
    Pickett, MH
    JOURNAL OF APPLIED PHYSIOLOGY, 1996, 81 (01) : 98 - 104
  • [48] Quality control of white cell-reduced red cells: White cell preservation and simplified counting
    Tran, K
    Nakajo, S
    Kapoor, V
    Chen, M
    Stromberg, RR
    TRANSFUSION, 1998, 38 (05) : 429 - 433
  • [49] Cryopreservation of red blood cells: Detailed quality control
    Lippert, S
    Bock, M
    Rahrig, S
    Kreutzmann, H
    Heim, MU
    TRANSFUSION MEDICINE 1995/1996, 1996, 33 : 117 - 120
  • [50] Statistical model for the process control of leukoreduced blood products
    Whitbread, J
    Finch, S
    Wenz, B
    Chen, J
    Bunch, C
    Brandwein, H
    BLOOD, 1996, 88 (10) : 3121 - 3121