PHOTONEUTRON CONTAMINATION FROM AN 18 MV SATURNE MEDICAL LINEAR ACCELERATOR IN THE TREATMENT ROOM

被引:9
|
作者
Khosravi, Mostafa [1 ,2 ]
Shahbazi-Gahrouei, Daryoush [1 ]
Jabbari, Keyvan [1 ]
Nasri-Nasrabadi, Mehdi [3 ]
Baradaran-Ghahfarokhi, Milad [1 ]
Siavashpour, Zahra [4 ]
Gheisari, Ruhollah [2 ,5 ]
Amiri, Behnam [6 ]
机构
[1] Isfahan Univ Med Sci, Sch Med, Dept Med Phys & Med Engn, Esfahan, Iran
[2] Radiat & Pollut Protect Ctr Mamasani, Fars, Iran
[3] Univ Isfahan, Sch Adv Sci & Technol, Dept Nucl Engn, Esfahan, Iran
[4] Shahid Beheshti Univ, Dept Med Radiat Engn, Tehran, Iran
[5] Persian Gulf Univ, Sch Sci, Dept Phys, Booshehr, Iran
[6] Sharif Tecnol Univ, Dept Mech Engn, Tehran, Iran
关键词
MONTE-CARLO; RADIATION-THERAPY; SIEMENS; VARIAN; ENTRANCE; SPECTRA; LINACS; BEAMS; MODEL; CODE;
D O I
10.1093/rpd/nct078
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Dose escalation with high-energy X rays of medical linear accelerators (linacs) in radiotherapy offers several distinct advantages over the lower energy photons. However, owing to photoneutron reactions, interaction of high-energy photons (>8 MV) with various high-Z nuclei of the materials in the linac head components produces unavoidable neutrons. The aim of this study was to evaluate the photoneutron dose equivalent per unit therapeutic X-ray dose of 18 MV, GE Saturne 20 linac in the treatment room using Monte Carlo (MC) MCNP linac head full simulation as well as thermoluminescence dosemeter measurements. This machine is one of the old linac models manufactured by General Electric Company; however, it is widely used in the developing countries because of low cost and simple maintenance for radiotherapy applications. The results showed a significant photoneutron dose from Saturne 20 linac head components especially at distances near the linac head (<150 cm). Results of this work could be used in several applications, especially designing bunker and entrance door shielding against neutrons produced by photoneutron reactions in GE Saturne 20. However, a detailed cost optimisation for a specific room would require a dedicated calculation.
引用
收藏
页码:356 / 363
页数:8
相关论文
共 50 条
  • [21] Measurement of photoneutron doses in and out of high-energy X-ray beam of a SATURNE-20 medical linear accelerator by ECE polycarbonate detectors
    Sohrabi, M
    Mostofizadeh, A
    RADIATION MEASUREMENTS, 1999, 31 (1-6) : 479 - 482
  • [22] OPERATIONAL RADIATION SAFETY FOR AN 8 MV MEDICAL LINEAR ACCELERATOR
    BUSHONG, SC
    HEALTH PHYSICS, 1970, 19 (01): : 81 - +
  • [23] A Study on Optimization of Photoneutron Shielding in a Medical Accelerator Room by Using Monte Carlo Simulation
    Kim, Yong Nam
    Choi, Sang Hyun
    Jeong, Kyoungkeun
    Kim, Joo Young
    Lee, Chang Geol
    Seong, Jinsil
    Kim, Chan Hyeong
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 50 - 53
  • [24] Monte Carlo estimation of photoneutrons spectra and dose equivalent around an 18 MV medical linear accelerator
    Alem-Bezoubiri, A.
    Bezoubiri, F.
    Badreddine, A.
    Mazrou, H.
    Lounis-Mokrani, Z.
    RADIATION PHYSICS AND CHEMISTRY, 2014, 97 : 381 - 392
  • [25] PHOSPHORUS NEUTRON DOSIMETRY FOR AN 18-MV LINEAR-ACCELERATOR
    BADING, JR
    ZEITZ, L
    LAUGHLIN, JS
    MEDICAL PHYSICS, 1981, 8 (04) : 587 - 587
  • [26] Peripheral neutron and gamma doses in radiotherapy with an 18 MV linear accelerator
    Vanhavere, F
    Huyskens, D
    Struelens, L
    RADIATION PROTECTION DOSIMETRY, 2004, 110 (1-4) : 607 - 612
  • [27] Characteristics of the photoneutron contamination present in a high-energy radiotherapy treatment room
    Garnica-Garza, HM
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (03): : 531 - 539
  • [28] A PRELIMINARY STUDY ON PHOTONEUTRON SHIELDING OPTIMIZATION IN A MEDICAL ACCELERATOR ROOM BY USING MONTE CARLO SIMULATION
    Kim, Y. N.
    Jeong, K.
    Lee, C. G.
    Lee, I. J.
    Seong, J.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S424 - S425
  • [29] Measurements of the neutron dose near a 15 Mv medical linear accelerator
    Golnik, N.
    Zielczynski, M.
    Bulski, W.
    Tulik, P.
    Palko, T.
    RADIATION PROTECTION DOSIMETRY, 2007, 126 (1-4) : 619 - 622
  • [30] DESIGN OF A TREATMENT ROOM FOR AN 18-MV LINAC
    Hernandez-Adame, Luis
    Contreras-Sandoval, Hector
    Rene Vega-Carrillo, Hector
    Perez Landeros, Leonel Humberto
    NUCLEAR TECHNOLOGY, 2011, 175 (01) : 105 - 112