End-Diastolic Fractional Flow Reserve Comparison With Conventional Full-Cardiac Cycle Fractional Flow Reserve

被引:8
|
作者
Chalyan, David A. [1 ,2 ]
Zhang, Zhang [1 ,3 ]
Takarada, Shigeho [4 ]
Molloi, Sabee [1 ]
机构
[1] Univ Calif Irvine, Dept Radiol Sci, Irvine, CA 92697 USA
[2] Univ Iowa, Roy J & Lucille A Carver Coll Med, Iowa City, IA USA
[3] Tianjin Med Univ Gen Hosp, Dept Radiol, Tianjin, Peoples R China
[4] Univ Calif Irvine, Div Cardiol, Orange, CA 92668 USA
关键词
CORONARY-ARTERY STENOSES; PHYSIOLOGICAL ASSESSMENT; PRESSURE MEASUREMENTS; FUNCTIONAL SEVERITY; CATHETERIZATION; VASODILATATION; VALIDATION; SWINE;
D O I
10.1161/CIRCINTERVENTIONS.113.000327
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Diastolic fractional flow reserve (dFFR) has been shown to be highly sensitive for detection of inducible myocardial ischemia. However, its reliance on measurement of left-ventricular pressure for zero-flow pressure correction, as well as manual extraction of the diastolic interval, has been its major limitation. Given previous reports of minimal zero-flow pressure at end-diastole, we compared instantaneous ECG-gated end-diastolic FFR with conventional fullcardiac cycle FFR and other diastolic indices in the porcine model. Methods and Results-Measurements of FFR in the left anterior descending and left circumflex arteries were performed in an open-chest swine model with an external occluder device on the coronary artery used to produce varying degrees of epicardial stenosis. An ultrasound flow-probe that was placed proximal to the occluder measured absolute blood flow in ml/min, and it was used as a gold standard for FFR measurement. A total of 17 measurements at maximal hyperemia were acquired in 5 animals. Correlation coefficient between conventional mean hyperemic FFR with pressure-wire and directly measured FFR with flow-probe was 0.876 (standard error estimate=0.069; P<0.0001). The hyperemic enddiastolic FFR with pressure-wire correlated better with FFR measured directly with flow-probe (r=0.941, standard error estimate=0.050; P<0.0001). Conclusions-Instantaneous hyperemic ECG-gated FFR acquired at end-diastole, as compared with conventional full-cardiac cycle FFR, has an improved correlation with FFR measured directly with ultrasound flow-probe. © 2014 American Heart Association, Inc.
引用
收藏
页码:28 / 34
页数:7
相关论文
共 50 条
  • [1] Left ventricular end-diastolic pressure affects measurement of fractional flow reserve
    Leonardi, Robert A.
    Townsend, Jacob C.
    Patel, Chetan A.
    Wolf, Bethany J.
    Todoran, Thomas M.
    Fernandes, Valerian L.
    Nielsen, Christopher D.
    Steinberg, Daniel H.
    Powers, Eric R.
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2013, 14 (04) : 218 - 222
  • [2] Diastolic fractional flow reserve to assess the functional severity of moderate coronary artery stenoses - Comparison with fractional flow reserve and coronary flow velocity reserve
    Abe, M
    Tomiyama, H
    Yoshida, H
    Doba, N
    CIRCULATION, 2000, 102 (19) : 2365 - 2370
  • [3] Coronary flow reserve and fractional flow reserve
    Ozyol, Ali
    Yilmaz, Mehmet Birhan
    TURK KARDIYOLOJI DERNEGI ARSIVI-ARCHIVES OF THE TURKISH SOCIETY OF CARDIOLOGY, 2007, 35 (04): : 253 - 261
  • [4] FRACTIONAL FLOW RESERVE
    Garcia, J. A.
    CARDIOLOGY, 2014, 128 : 33 - 33
  • [5] Fractional flow reserve
    Yadava O.P.
    Casselman F.
    Indian Journal of Thoracic and Cardiovascular Surgery, 2018, 34 (4) : 533 - 533
  • [6] Impact of Right Atrial Pressure on Fractional Flow Reserve Measurements Comparison of Fractional Flow Reserve and Myocardial Fractional Flow Reserve in 1,600 Coronary Stenoses
    Toth, Gabor G.
    De Bruyne, Bernard
    Rusinaru, Dan
    Di Gioia, Giuseppe
    Bartunek, Jozef
    Pellicano, Mariano
    Vanderheyden, Marc
    Adjedj, Julien
    Wijns, William
    Pijls, Nico H. J.
    Barbato, Emanuele
    JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (05) : 453 - 459
  • [7] Clinical comparison study between a newly developed optical-based fractional flow reserve device and the conventional fractional flow reserve device
    Saka, Yuki
    Tanaka, Akihito
    Ishii, Hideki
    Takashima, Hiroaki
    Suzuki, Akihiro
    Nakano, Yusuke
    Sakurai, Shinichiro
    Ando, Hirohiko
    Murohara, Toyoaki
    Amano, Tetsuya
    CORONARY ARTERY DISEASE, 2020, 31 (04) : 342 - 347
  • [8] History of Cardiac CT and Conventional, Invasive Fractional Flow Reserve's Effect
    Wininger, Kevin L.
    RADIOLOGIC TECHNOLOGY, 2024, 95 (06) : 424 - 433
  • [9] Diastolic fractional flow reserve (FFR) closely tracks whole-cycle FFR
    Johnson, Nils P.
    van't Veer, Marcel
    Kirkeeide, Richard L.
    Oldroyd, Keith G.
    Gould, K. L.
    Berry, Colin
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (11) : B93 - B94
  • [10] Comparison of conventional and diastolic fractional flow reserve after adenosine and dobutamine infusions for hemodynamic assessment of myocardial bridging
    Aleksandric, S.
    Dobric, M.
    Teofilovski-Parapid, G.
    Tomasevic, M.
    Vukcevic, V.
    Stojkovic, S.
    Stankovic, G.
    Saponjski, J.
    Orlic, D.
    Beleslin, B.