Amlodipine Bioequivalence study: Quantification by liquid chromatography coupled to tandem mass spectrometry

被引:43
|
作者
Carvalho, M
Oliveira, CH
Mendes, GD
Sucupira, M
Moraes, MEA
De Nucci, G
机构
[1] UNICAMP, State Univ Campinas, Dept Pharmacol, Campinas, SP, Brazil
[2] USP, ICB, Dept Pharmacol, Cartesius Analyt Unit, BR-09500900 Sao Paulo, Brazil
[3] Fed Univ Ceara, Dept Pharmacol, Fortaleza, Ceara, Brazil
关键词
pharmacokinetics; desipramine; HPLC; LC-MS-MS;
D O I
10.1002/bdd.282
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Objective-To assess the bioequivalence of two amlodipine tablet formulations (Amlodipine(R) 5 mg tablet from Merck S.A. Industrias Quimicas, Brazil as test formulation and Norvasc(R) 5 mg tablet from Laboratorios Pfizer Ltd., Brazil as reference formulation) in 24 healthy volunteers of both sexes. Methods-The study Was conducted using an open, randomized two-period crossover design with a 4-week washout interval. Plasma samples were obtained over a 144 h period. Plasma amlodipine concentrations were analyzed by combined liquid chromatography coupled to tandem mass spectrometry (LC-MS-MS) with positive ion electrospray ionization using multiple reaction monitoring (MRM). From the amiodipine plasma concentration vs time curves, the following pharmacokinetic parameters were obtained: AUC(last), AUC(0-inf) and C-max. The statistical interval proposed was 80-125% according to the US Food and Drug Administration Agency. Results-The limit of quantification was 0.1 ng/ml for plasma amlodipine analysis. The geometric mean and the 90% confidence interval (CI) test/reference ratios were 101.2 (92.9-110.2%) for AUC(last), 99.6 (91.5-108.4%) for AUC(0-inf), and 98.5 (89.0-109.1%) for C-max. Conclusion-Since the 90% Cl for AUC(last), AUC(0-inf) and C-max ratios were within in the 80-125% interval proposed by the US FDA, it was concluded that Amlodipine(R) 5 mg tablet (test formulation) was bioequivalent to Norvasc(R) 5 mg tablet, in terms of both rate and extent of absorption. Copyright (C), 2001 John Wiley Sons, Ltd.
引用
收藏
页码:383 / 390
页数:8
相关论文
共 50 条
  • [21] Quantification of metaxalone in human plasma by liquid chromatography coupled to tandem mass spectrometry
    Nirogi, RVS
    Kandikere, VN
    Shukla, M
    Mudigonda, K
    Shrivastava, W
    Datla, PV
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2006, 30 (04) : 245 - 251
  • [22] Quantification of tizanidine in human plasma by liquid chromatography coupled to tandem mass spectrometry
    Nirogi, Ramakrishna V. S.
    Kandikere, Vishwottam N.
    Shukla, Manoj
    Mudigonda, Koteshwara
    Maurya, Santosh
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (15) : 2286 - 2292
  • [23] Ticlopidine quantification in human plasma by high-performance liquid chromatography coupled to electrospray tandem mass spectrometry. Application to bioequivalence study
    Borges, NCD
    Mendes, GD
    Borges, A
    de Oliveira, SE
    Barrientos-Astigarraga, RE
    De Nucci, G
    JOURNAL OF MASS SPECTROMETRY, 2004, 39 (12): : 1562 - 1569
  • [24] Nevirapine quantification in human plasma by high-performance liquid chromatography coupled to electrospray tandem mass spectrometry. Application to bioequivalence study
    Laurito, TL
    Santagada, V
    Caliendo, G
    Oliveira, CH
    Barrientos-Astigarraga, RE
    De Nucci, G
    JOURNAL OF MASS SPECTROMETRY, 2002, 37 (04): : 434 - 441
  • [25] Gabapentin quantification in human plasma by high-performance liquid chromatography coupled to electrospray tandem mass spectrometry. Application to bioequivalence study
    Ifa, DR
    Falci, M
    Moraes, ME
    Bezerra, FAF
    Moraes, MO
    de Nucci, G
    JOURNAL OF MASS SPECTROMETRY, 2001, 36 (02): : 188 - 194
  • [26] Determination of paroxetine in plasma by liquid chromatography coupled to tandem mass spectrometry for pharmacokinetic and bioequivalence studies
    Jhee, Ok Hwa
    Seo, Hee Kyoung
    Lee, Min Ho
    Jeon, Yong Cheol
    Shaw, Leslie M.
    Lee, Seung Hoon
    Hur, Yeon
    Kim, Kwang-Hyun
    Lee, Heon-Soo
    Lee, Seo Eun
    Kang, Ju Seop
    ARZNEIMITTELFORSCHUNG-DRUG RESEARCH, 2007, 57 (07): : 455 - 461
  • [27] High-throughput quantification of perindopril in human plasma by liquid chromatography/tandem mass spectrometry: application to a bioequivalence study
    Nirogi, RVS
    Kandikere, VN
    Shukla, M
    Mudigonda, K
    Maurya, S
    Komarneni, P
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (12) : 1864 - 1870
  • [28] Quantification of atorvastatin in human plasma by liquid chromatography tandem mass spectrometry and its application for bioequivalence study of three formulations
    Yahdiana Harahap
    Santi Purnasari
    Harmita
    Rina Rahmawati
    Krisnasari Dian
    Pratami
    Witri Sansris
    Siti Fatriyah
    AsianJournalofPharmaceuticalSciences, 2016, 11 (01) : 66 - 67
  • [29] Quantification of propiverine by liquid chromatography/electrospray tandem mass spectrometry: Application to a bioequivalence study of two formulations in healthy subjects
    Cho, SH
    Lee, HW
    Im, HT
    Park, WS
    Baek, M
    Lee, KT
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 39 (3-4) : 670 - 676
  • [30] Study on pharmacokinetics and bioequivalence of Vonoprazan pyroglutamate in rats by liquid chromatography with tandem mass spectrometry
    Qiao, Yuan
    Zhao, Jun
    Yue, Xuanfeng
    Zhang, Yang
    Zhang, Ruitao
    Xu, Yuan
    Tang, Xiuling
    Liu, Xueying
    Wang, Qingwei
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2017, 1059 : 56 - 65