Perfusion phantom: An efficient and reproducible method to simulate myocardial first-pass perfusion measurements with cardiovascular magnetic resonance

被引:33
|
作者
Chiribiri, Amedeo [1 ,2 ,3 ]
Schuster, Andreas [1 ,2 ,3 ]
Ishida, Masaki [1 ,2 ,3 ]
Hautvast, Gilion [4 ]
Zarinabad, Niloufar [1 ,2 ,3 ]
Morton, Geraint [1 ,2 ,3 ]
Otton, James [1 ,2 ,3 ]
Plein, Sven [1 ,2 ,3 ,5 ]
Breeuwer, Marcel [4 ,6 ]
Batchelor, Philip [1 ,2 ,3 ]
Schaeffter, Tobias [1 ,2 ,3 ]
Nagel, Eike [1 ,2 ,3 ]
机构
[1] Kings Coll London, NIHR Biomed Res Ctr, Div Imaging Sci, BHF Ctr Excellence, London SE1 7EH, England
[2] Wellcome Trust Res Labs, London, England
[3] Guys & St Thomas NHS Fdn Trust, Rayne Inst, EPSRC Med Engn Ctr, London, England
[4] Philips Healthcare, Imaging Syst MR, Best, Netherlands
[5] Univ Leeds, Div Cardiovasc & Neuronal Remodelling, Leeds, W Yorkshire, England
[6] Eindhoven Univ Technol, Dept Biomed Engn, NL-5600 MB Eindhoven, Netherlands
基金
英国惠康基金; 英国工程与自然科学研究理事会;
关键词
first-pass perfusion MR; phantom; gadolinium; 3T; heart; CORONARY-ARTERY-DISEASE; MODEL-INDEPENDENT DECONVOLUTION; POSITRON-EMISSION-TOMOGRAPHY; BLOOD-FLOW; CONTRAST AGENTS; HEALTHY HUMANS; K-SPACE; RESERVE; MRI; QUANTIFICATION;
D O I
10.1002/mrm.24299
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this article is to describe a novel hardware perfusion phantom that simulates myocardial first-pass perfusion allowing comparisons between different MR techniques and validation of the results against a true gold standard. MR perfusion images were acquired at different myocardial perfusion rates and variable doses of gadolinium and cardiac output. The system proved to be sensitive to controlled variations of myocardial perfusion rate, contrast agent dose, and cardiac output. It produced distinct signal intensity curves for perfusion rates ranging from 1 to 10 mL/mL/min. Quantification of myocardial blood flow by signal deconvolution techniques provided accurate measurements of perfusion. The phantom also proved to be very reproducible between different sessions and different operators. This novel hardware perfusion phantom system allows reliable, reproducible, and efficient simulation of myocardial first-pass MR perfusion. Direct comparison between the results of image-based quantification and reference values of flow and myocardial perfusion will allow development and validation of accurate quantification methods. Magn Reson Med, 2013. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:698 / 707
页数:10
相关论文
共 50 条
  • [41] Pulmonary transit time is a predictor of outcomes in heart failure: a cardiovascular magnetic resonance first-pass perfusion study
    Farley, Jonathan
    Brown, Louise A. E.
    Garg, Pankaj
    Wahab, Ali
    Klassen, Joel R. L.
    Jex, Nicholas
    Thirunavukarasu, Sharmaine
    Chowdhary, Amrit
    Sharrack, Noor
    Gorecka, Miroslawa
    Xue, Hui
    Artis, Nigel
    Levelt, Eylem
    Dall'Armellina, Erica
    Kellman, Peter
    Greenwood, John P.
    Plein, Sven
    Swoboda, Peter P.
    [J]. BMC CARDIOVASCULAR DISORDERS, 2024, 24 (01):
  • [42] Contrast-enhanced first-pass myocardial perfusion magnetic resonance Imaging with parallel acquisition at 3.0 tesla
    Ruan, Chun
    Yang, Scott H.
    Cusi, Kenneth
    Gao, Feng
    Clarke, Geoffrey D.
    [J]. INVESTIGATIVE RADIOLOGY, 2007, 42 (06) : 352 - 360
  • [43] In-vivo right ventricular myocardial perfusion assessment using BOLD and first-pass cardiac magnetic resonance
    David S Fieno
    Steven M Shea
    Yongzhong Li
    Debiao Li
    [J]. Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
  • [44] Cardiovascular magnetic resonance: Myocardial perfusion
    Nagel, E
    Al-Saadi, N
    Fleck, E
    [J]. HERZ, 2000, 25 (04) : 409 - 416
  • [45] Cardiovascular Magnetic Resonance: Myocardial Perfusion
    Eike Nagel
    Nidal Al-Saadi
    Eckart Fleck
    [J]. Herz, 2000, 25 : 409 - 416
  • [46] Myocardial perfusion in cardiovascular magnetic resonance
    Misko, Jolanta
    Petryka, Joanna
    Mazurkiewicz, Lukasz
    [J]. POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2011, 7 (01): : 79 - 86
  • [47] A myocardial perfusion reserve index in humans using first-pass contrast-enhanced magnetic resonance imaging
    Cullen, JHS
    Horsfield, MA
    Reek, CR
    Cherryman, GR
    Barnett, DB
    Samani, NJ
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 33 (05) : 1386 - 1394
  • [48] The additive effects of obesity on myocardial microcirculation in diabetic individuals: a cardiac magnetic resonance first-pass perfusion study
    Li Jiang
    Ke Shi
    Ying-kun Guo
    Yan Ren
    Zhen-lin Li
    Chun-chao Xia
    Lei Li
    Xi Liu
    Lin-jun Xie
    Yue Gao
    Meng-ting Shen
    Ming-yan Deng
    Zhi-gang Yang
    [J]. Cardiovascular Diabetology, 19
  • [49] Perceived Dark Rim Artifact in First-Pass Myocardial Perfusion Magnetic Resonance Imaging Due to Visual Illusion
    Shin, Taehoon
    Nayak, Krishna S.
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2020, 21 (04) : 462 - 470
  • [50] Going with the flow: how reproducible are cardiac magnetic resonance measurements of myocardial perfusion?
    Biglands, John
    Plein, Sven
    [J]. JOURNAL OF THORACIC DISEASE, 2013, 5 (03) : 371 - 372