Sapphire ball lens-based fiber probe for common-path optical coherence tomography and its applications in corneal and retinal imaging

被引:31
|
作者
Zhao, Mingtao [1 ]
Huang, Yong [1 ]
Kang, Jin U. [1 ]
机构
[1] Johns Hopkins Univ, Dept Elect & Comp Engn, Baltimore, MD 21218 USA
基金
美国国家卫生研究院;
关键词
HIGH-RESOLUTION;
D O I
10.1364/OL.37.004835
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We describe a common-path swept source optical coherence tomography fiber probe design using a sapphire ball lens for cross-sectional imaging and sensing for retina vitrectomy surgery. The high refractive index (n = 1.75) of the sapphire ball lens improves the focusing power and enables the probe to operate in the intraocular space. The highly precise spherical shape of the sapphire lens also reduces astigmatism and coma compared to fused nonspherical ball lenses. A theoretical sensitivity model for common-path optical coherence tomography (CP-OCT) was developed to assess its optimal performance based on an unbalanced photodetector configuration. Two probe designs-with working distances 415 and 1221 mu m and lateral resolution 11 and 18 mu m-were implemented with sensitivity up to 88 dB, which is significantly higher than previously reported CP-OCT probes. We assessed the performances of the fiber probes by cross-sectional imaging a bovine cornea and retina in air and in vitreous gel with a 1310 nm swept source OCT system. To the best of our knowledge, this is the first demonstration of sapphire ball lens-based CP-OCT probes directly inserted into the vitreous gel of a bovine eyeball for ocular imaging with a sensitivity approaching the theoretical limitation of CP-OCT. (C) 2012 Optical Society of America
引用
收藏
页码:4835 / 4837
页数:3
相关论文
共 50 条
  • [31] Signal-to-noise ratio analysis of all-fiber common-path optical coherence tomography
    Li, Xiaolu
    Han, Jae-Ho
    Liu, Xuan
    Kang, Jin U.
    APPLIED OPTICS, 2008, 47 (27) : 4833 - 4840
  • [32] Speckle Reduction during All-Fiber Common-Path Optical Coherence Tomography of the Cavernous Nerves
    Chitchian, Shahab
    Fiddy, Michael
    Fried, Nathaniel M.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XIII, 2009, 7168
  • [33] Noncontact common-path Fourier domain optical coherence tomography method for in vitro intraocular lens power measurement
    Huang, Yong
    Zhang, Kang
    Kang, Jin U.
    Calogero, Don
    James, Robert H.
    Ilev, Ilko K.
    JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (12)
  • [34] Stable fiber-based polarization-sensitive optical coherence tomography using polarization maintaining common-path interferometer
    Tang, Peijun
    Wang, Ruikang K.
    JOURNAL OF BIOMEDICAL OPTICS, 2020, 25 (11)
  • [35] High-resolution subsurface articular cartilage imaging based on Fourier-domain common-path optical coherence tomography
    Han, Jae-Ho
    Liu, Xuan
    Kang, Jin U.
    Song, Chul Gyu
    CHINESE OPTICS LETTERS, 2010, 8 (02) : 167 - 169
  • [36] High-resolution subsurface articular cartilage imaging based on Fourier-domain common-path optical coherence tomography
    Jae-Ho Han
    Jin U.Kang
    Chul Gyu Song
    Chinese Optics Letters, 2010, 8 (02) : 167 - 169
  • [37] Experimental and Theoretical Investigation of Common Path Optical Coherence Tomography Using Conical Tip Lens Fiber
    Sugiyama, J.
    Taguchi, K.
    IRAGO CONFERENCE 2012, 2013, 433
  • [38] A Surface Topology and Motion Compensation System for Microsurgery Guidance and Intervention Based on Common-Path Optical Coherence Tomography
    Zhang, Kang
    Wang, Weichao
    Han, Jaeho
    Kang, Jin U.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (09) : 2318 - 2321
  • [39] Reflective axicon based energy-efficient extended depth of focus quasi-Bessel beam probe for common-path optical coherence tomography
    Vairagi, Kaushal
    Gupta, Pooja
    Tiwari, Umesh Kumar
    Mondal, Samir K.
    APPLIED OPTICS, 2023, 62 (03) : 511 - 517
  • [40] Simultaneous imaging and measurement of tensile stress on cornea by using a common-path optical coherence tomography system with an external contact reference
    Utkarsh Sharma
    Jin U.Kang
    Chinese Optics Letters, 2008, 6 (12) : 910 - 912