Measurement and evaluation of natural and artificial UV radiation

被引:0
|
作者
Krins, A
Burger, PM
Dörschel, B
Knuschke, P
机构
[1] Tech Univ Dresden, Dermatol Klin, D-01307 Dresden, Germany
[2] Tech Univ Dresden, Inst Strahlenschutzphys, D-01307 Dresden, Germany
来源
HAUTARZT | 1999年 / 50卷 / 10期
关键词
biologically weighting; polysulphone; spore dosimetry; UV dosimetry; UV radiation;
D O I
10.1007/s001050051054
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Natural and artificial UV radiation are environmental factors with both beneficial and harmful biological effects. This article will explain the physical measurement quantities and their relation to the biologically effective dose and will summarize the present technical state of the art of personal UV monitoring. In practical use are dosimeters based on polysulphone, a polymer which undergoes changes in its optical properties upon irradiation with UV. Other systems determine the UV dose by quantifying damage induced in Bacillus subtilis spores upon UV exposure. An electronic UV sensor represents a new and interesting development Personal UV dosimeters will become an useful tool in both clinical and scientific areas within dermatology.
引用
收藏
页码:701 / 705
页数:5
相关论文
共 50 条
  • [41] Artificial UV radiation from an occupational health point of view
    Drexler, H.
    ALLERGOLOGIE, 2010, 33 (08) : 368 - 369
  • [42] Effect of UV radiation and artificial acid rain on productivity of wheat
    Badridze, G.
    Kacharava, N.
    Chkhubianishvili, E.
    Rapava, L.
    Kikvidze, M.
    Chanishvili, Sh.
    Shakarishvili, N.
    Mazanishvili, L.
    Chigladze, L.
    RUSSIAN JOURNAL OF ECOLOGY, 2016, 47 (02) : 158 - 166
  • [43] SKIN-CANCER AND ARTIFICIAL SOURCES OF UV-RADIATION
    MORISON, WL
    JOURNAL OF DERMATOLOGIC SURGERY AND ONCOLOGY, 1988, 14 (08): : 893 - 896
  • [44] RADIATIVE MODELS FOR THE EVALUATION OF THE UV RADIATION AT THE GROUND
    Koepke, P.
    RADIATION PROTECTION DOSIMETRY, 2009, 137 (3-4) : 188 - 192
  • [45] A simple device for the evaluation of the UV radiation index
    Casale, GR
    Siani, AM
    Lucarini, C
    Catamo, M
    METEOROLOGICAL APPLICATIONS, 2003, 10 (02) : 115 - 121
  • [46] The evaluation of a natural pigment in cotton as a UV absorber
    Gorensek, Maria
    Urbas, Rasa
    Strnad, Simona
    Parac-Osterman, Durdica
    AATCC REVIEW, 2007, 7 (08) : 49 - 55
  • [47] Recombination Radiation in Synthetic and Natural Diamonds Exposed to Pulsed UV Laser Radiation
    E. I. Lipatov
    D. E. Genin
    V. F. Tarasenko
    Russian Physics Journal, 2015, 58 : 911 - 922
  • [48] Recombination Radiation in Synthetic and Natural Diamonds Exposed to Pulsed UV Laser Radiation
    Lipatov, E. I.
    Genin, D. E.
    Tarasenko, V. F.
    RUSSIAN PHYSICS JOURNAL, 2015, 58 (07) : 911 - 922
  • [49] MICROBIOLOGICAL INVESTIGATIONS CONCERNING THE IMPORTANCE OF NATURAL AND ARTIFICIAL SIMULATED WATER TRANSMISSION FOR THE EVALUATION OF UV-DISINFECTION PLANTS
    LEUKER, G
    HINGST, V
    ZENTRALBLATT FUR HYGIENE UND UMWELTMEDIZIN, 1990, 190 (04): : 365 - 379
  • [50] THE MEASUREMENT OF THE NATURAL RADIATION BACKGROUND IN A SALT MINE
    Stochioiu, Ana
    Bercea, Sorin
    Sahagia, Maria
    Ivan, Constantin
    Tudor, Ion
    Celarel, Aura
    ROMANIAN JOURNAL OF PHYSICS, 2011, 56 (5-6): : 757 - 761