Plasma-source sector mass spectrometry with array detection

被引:23
|
作者
Solyom, DA [1 ]
Burgoyne, TW [1 ]
Hieftje, GM [1 ]
机构
[1] Indiana Univ, Dept Chem, Bloomington, IN 47405 USA
关键词
D O I
10.1039/a900272c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The combination of a mass spectrograph and an array detector possesses several potential advantages over more conventional methods of mass spectrometric analysis. The desirable features of this instrumental combination result from its most important quality, the ability to perform simultaneous analysis of an entire m/z range. These advantages include greater throughput (Felgett advantage), greater precision through isotope ratio determination, and superior analysis of fast, transient signals such as those produced by gas and liquid chromatographies, capillary electrophoresis, flow injection analysis, and laser ablation. Currently, two research groups are investigating the utility of incorporating ionization sources suitable for elemental analysis to mass spectrograph/array detector instrumentation. While progress has been made in both research groups, each project still has significant work ahead in order to realize fully the advantages of a sector mass spectrometer/array detector system. This review focuses primarily on the efforts of these two groups over approximately the last 6 years. However, basic discussions on several other topics including array detectors, the Mattauch-Herzog spectrograph geometry, and fundamental differences between simultaneous and scanning data acquisition are also presented.
引用
收藏
页码:1101 / 1110
页数:10
相关论文
共 50 条
  • [23] PLASMA SOURCE-MASS SPECTROMETRY
    HIEFTJE, GM
    NORMAN, LA
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 118 : 519 - 573
  • [24] Plasma mass spectrometry: consider the source
    Sheppard, Brenda S., 1600, (09):
  • [25] Key issues in plasma-source ion implantation
    Rej, DJ
    Faehl, RJ
    Matossian, JN
    SURFACE & COATINGS TECHNOLOGY, 1997, 96 (01): : 45 - 51
  • [26] MULTI-ELEMENTAL ANALYSIS OF HUMAN-MILK BY INDUCTIVELY COUPLED PLASMA-SOURCE MASS-SPECTROMETRY - IMPLICATIONS FOR INFANT HEALTH
    DURRANT, SF
    WARD, NI
    JOURNAL OF MICRONUTRIENT ANALYSIS, 1989, 5 (02): : 111 - 126
  • [27] Incorporation of an electro-optic ion detector into an improved plasma-source mass spectrograph
    Solyom, DA
    Barnes, JH
    Gron, OA
    Hieftje, GM
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2002, 22 (05) : 828 - 837
  • [28] COMPUTER-SIMULATION OF MASS-SELECTIVE PLASMA-SOURCE ION-IMPLANTATION
    SHOHET, JL
    WICKESBERG, EB
    KUSHNER, MJ
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1994, 12 (04): : 1380 - 1386
  • [29] Plasma source mass spectrometry in experimental nutrition
    Barnes, RM
    MATHEMATICAL MODELLING IN EXPERIMENTAL NUTRITION, 1998, 445 : 379 - 396
  • [30] DEVELOPMENTS IN PLASMA SOURCE-MASS SPECTROMETRY
    HIEFTJE, GM
    VICKERS, GH
    ANALYTICA CHIMICA ACTA, 1989, 216 (1-2) : 1 - 24