Utilizing monte carlo for log file-based delivery QA

被引:0
|
作者
Stanhope, C. [1 ]
Drake, D. [1 ]
Alber, M. [2 ]
Sohn, M. [2 ]
Liang, J. [1 ]
Habib, C. [1 ]
Yan, D. [1 ]
机构
[1] Beaumont Hlth Syst, Radiat Oncol, Royal Oak, MI USA
[2] Sci RT, Munich, Germany
关键词
D O I
10.1016/S0167-8140(17)31357-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PO-0920
引用
收藏
页码:S509 / S510
页数:2
相关论文
共 50 条
  • [1] Anatomically-Based Log File QA Using Monte Carlo as An Alternative Patient-Specific QA Technique
    Stanhope, C.
    Liang, J.
    Drake, D.
    Yan, D.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2893 - 2893
  • [2] Clinical implementation of a log file-based machine and patient QA system for IMRT and VMAT treatment plans
    Silvestri, Valerio
    Raspanti, Davide
    Guerrisi, Maria Giovanna
    Falco, Maria Daniela
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 108
  • [3] Is the Standard IMRT/VMAT QA Good Enough? Investigating Log File Monte Carlo-Based Quality Assurance (LF-MC QA) as An Alternative Treatment Planning/Delivery QA Technique
    Stanhope, C.
    Alber, M.
    Sohn, M.
    Drake, D.
    Liang, J.
    Yan, D.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E245 - E245
  • [4] Monte Carlo based RapidArc QA using LINAC log files
    Teke, T.
    Bergman, A.
    Kwa, W.
    Gill, B.
    Duzenli, C.
    Popescu, I. A.
    [J]. MEDICAL PHYSICS, 2009, 36 (09) : 4302 - 4302
  • [5] Evaluation of Ion Chamber/film and Log File Based QA to Detect Delivery Errors
    Nelson, C.
    Ohrt, J.
    Mason, B.
    Kirsner, S.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3424 - 3424
  • [6] A Novel QA Process Based On Monte Carlo 2nd Check and Dose Reconstruction From Machine Log File On TomoTherapy
    Chen, Q.
    Handsfield, L.
    Wilson, D.
    Larner, J.
    Read, P.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [7] Log file based Monte Carlo calculations for proton pencil beam scanning therapy
    Winterhalter, Carla
    Meier, Gabriel
    Oxley, David
    Weber, Damien C.
    Lomax, Antony J.
    Safai, Sairos
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (03):
  • [8] Monte Carlo Dose Calculations for Patient-Specific QA Based On Machine Log Files
    Parenica, H.
    Kabat, C.
    Papaconstadopoulos, P.
    Kirby, N.
    Myers, P.
    Wagner, T.
    Papanikolaou, N.
    Stathakis, S.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [9] Monte Carlo based, patient-specific RapidArc QA using Linac log files
    Teke, Tony
    Bergman, Alanah M.
    Kwa, William
    Gill, Bradford
    Duzenli, Cheryl
    Popescu, I. Antoniu
    [J]. MEDICAL PHYSICS, 2010, 37 (01) : 116 - 123
  • [10] Log file based QA in practice - photon beam therapy
    Papanikolaou, N.
    Kabat, C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S415 - S416