Dynamics of ion loading into a linear Paul trap using an inductively coupled plasma mass spectrometer

被引:7
|
作者
Kitaoka, Masanori [1 ]
Jung, Kyunghun [1 ]
Yamamoto, Yuta [1 ]
Yoshida, Takuma [1 ]
Hasegawa, Shuichi [1 ,2 ]
机构
[1] Univ Tokyo, Sch Engn, Dept Syst Innovat, Bunkyo Ku, Tokyo 1138656, Japan
[2] Univ Tokyo, Nucl Profess Sch, Naka, Ibaraki 3181199, Japan
关键词
ICP-MS; CA+ IONS; CALCIUM; CA-41; COLLISION;
D O I
10.1039/c3ja50023c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We report on the dynamics of loading calcium ions into a linear Paul trap with ICP-MS. Ions are transported from the ICP-MS to the ion trap and isotopes are selectively laser-cooled, and then their laser induced fluorescence (LIF) is observed. We investigated the relationship between LIF and isotopic concentration in liquid samples and successfully obtained a calibration curve. This technique provides a novel tool for isotope analysis based on laser spectroscopy.
引用
收藏
页码:1648 / 1654
页数:7
相关论文
共 50 条
  • [31] Uranium isotopic analyses by using a sector field inductively coupled plasma mass spectrometer
    Furusawa, HA
    Sarkis, JES
    Kakazu, MH
    Rodrigues, C
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1999, 242 (03) : 647 - 651
  • [32] Uranium isotopic analyses by using a sector field inductively coupled plasma mass spectrometer
    H. A. Furusawa
    J. E. S. Sarkis
    M. H. Kakazu
    C. Rodrigues
    Journal of Radioanalytical and Nuclear Chemistry, 1999, 242 : 647 - 651
  • [33] Isotope measurements in uranium using a quadrupole inductively coupled plasma mass spectrometer (ICPMS)
    O. P. Oliveira
    J. E. S. Sarkis
    Journal of Radioanalytical and Nuclear Chemistry, 2002, 253 : 345 - 350
  • [34] Linear Ion Trap Mass Spectrometer (LITMS) for in situ Astrobiology
    Li, Xiang
    Grubisic, Andrej
    Brinckerhoff, William B.
    Castillo, Marco
    Arevalo, Ricardo
    van Amerom, Friso
    Danell, Ryan
    Kaplan, Desmond
    Zacny, Kris
    Chu, Philip
    2019 IEEE AEROSPACE CONFERENCE, 2019,
  • [35] Ion deposition by inductively coupled plasma mass spectrometry
    Hu, K
    Houk, RS
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1996, 14 (02): : 370 - 373
  • [36] A digital ion trap mass spectrometer coupled with atmospheric pressure ion sources
    Ding, L
    Sudakov, M
    Brancia, FL
    Giles, R
    Kumashiro, S
    JOURNAL OF MASS SPECTROMETRY, 2004, 39 (05): : 471 - 484
  • [37] SIMPLEX APPROACH TO THE OPTIMIZATION OF THE ION OPTICS BIAS POTENTIALS OF AN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETER
    SCHMIT, JP
    CHAUVETTE, A
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (08) : 755 - 759
  • [38] Theoretical Studies for Arsenic Interferences by Inductively Coupled Plasma Mass Spectrometer
    Rashad, A. M.
    Abdel-Hafiez, A.
    ARAB JOURNAL OF NUCLEAR SCIENCES AND APPLICATIONS, 2018, 51 (03): : 43 - 50
  • [39] Application of an Orthogonal Method for Optimizing an Inductively Coupled Plasma Mass Spectrometer
    Honglin Yuan
    Shenghong Hu
    Soulin Lin
    Shan Gao
    Analytical Sciences, 2002, 18 : 701 - 704
  • [40] MOLECULAR IONIZATION IN THE INTERFACE OF AN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETER
    TOGASHI, H
    HASHIZUME, A
    NIWA, Y
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1992, 47 (04) : 561 - 568