Combination of flow injection with capillary electrophoresis .1. The basic system

被引:108
|
作者
Fang, ZL [1 ]
Liu, ZS [1 ]
Shen, Q [1 ]
机构
[1] SHENYANG PHARMACEUT UNIV, SHENYANG 110015, PEOPLES R CHINA
关键词
flow injection; capillary electrophoresis; electrokinetic sample introduction;
D O I
10.1016/S0003-2670(97)00082-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A combined flow injection (FI)-capillary electrophoresis (CE) system was developed using conventional Fl and CE equipment. A flow-through reservoir equipped with a conical inlet was used as an interface to connect the Fl system to the capillary inlet. A grounded electrode was inserted in the reservoir. Split-sampling was achieved in the electrokinetic mode when an injected sample zone in the microliter range was transported into the conical inlet by a carrier solution which also served as the separation buffer. Using benzoic acid as a model the combined system demonstrated significantly improved precision in peak height, peak area, and migration time as compared to conventional manual electrokinetic sample introduction while achieving similar sensitivity and column efficiency. Using a test sample containing magnolol and benzoic acid, a series of samples was injected continuously without current interruption, achieving sample throughputs at least three times higher than conventional CE sample introduction.
引用
收藏
页码:135 / 143
页数:9
相关论文
共 50 条
  • [21] NEOCHROMATOGRAPHIC TECHNOLOGIES .1. CAPILLARY ELECTROPHORESIS
    WIDMER, HM
    [J]. CHIMIA, 1989, 43 (05) : 134 - 141
  • [22] The combination of flow injection with electrophoresis using capillaries and chips
    Lue, Wen-juan
    Chen, Yong-lei
    Zhu, Jin-hua
    Chen, Xing-guo
    [J]. ELECTROPHORESIS, 2009, 30 (01) : 83 - 91
  • [23] Combination of flow injection with electrophoresis using capillaries and chips
    Chen, Yonglei
    Lu, Wenjuan
    Chen, Xingguo
    Hu, Zhide
    [J]. ELECTROPHORESIS, 2007, 28 (1-2) : 33 - 44
  • [24] The combination of flow injection with electrophoresis using capillaries and chips
    Chen, XG
    Fan, LY
    Hu, Z
    [J]. ELECTROPHORESIS, 2004, 25 (23-24) : 3962 - 3969
  • [25] PERFORMANCE OF AN AUTOMATED INJECTION AND REPLENISHMENT SYSTEM FOR CAPILLARY ELECTROPHORESIS
    SCHWARTZ, HE
    MELERA, M
    BROWNLEE, RG
    [J]. JOURNAL OF CHROMATOGRAPHY, 1989, 480 : 129 - 139
  • [26] Flow injection/capillary electrophoresis/electroinjection - A happy marriage.
    Christian, GD
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 226 : U120 - U120
  • [27] New interface for coupling flow-injection and capillary electrophoresis
    Kuban, P
    Engstrom, A
    Olsson, JC
    Thorsen, G
    Tryzell, R
    Karlberg, B
    [J]. ANALYTICA CHIMICA ACTA, 1997, 337 (02) : 117 - 124
  • [28] On-line conversion and determination of aspirin using a flow injection-capillary electrophoresis system
    Chen, HL
    Fan, LY
    Chen, XG
    Hu, ZD
    Zhao, ZF
    Hooper, M
    [J]. JOURNAL OF SEPARATION SCIENCE, 2003, 26 (9-10): : 863 - 868
  • [29] Combination of flow injection with capillary electrophoresis. Part 6. A bias-free sample introduction system based on electroosmotic-flow traction
    Pu, QS
    Fang, ZL
    [J]. ANALYTICA CHIMICA ACTA, 1999, 398 (01) : 65 - 74
  • [30] On-line conversion and determination of artemisinin using a flow-injection capillary electrophoresis system
    Chen, HL
    Wang, KT
    Pu, QS
    Chen, XG
    Hu, ZD
    [J]. ELECTROPHORESIS, 2002, 23 (17) : 2865 - 2871