Electric power frequency and nuclear safety - Subsynchronous resonance case study

被引:2
|
作者
Volkanovski, Andrija [1 ]
Prosek, Andrej [1 ]
机构
[1] Jozef Stefan Inst, Reactor Engn Div R4, Jamova Cesta 39, SI-1000 Ljubljana, Slovenia
关键词
Subsynchronous resonance; Reactor coolant pumps; RELAP5; STATION BLACKOUT; REACTOR; SYSTEM; MITIGATION;
D O I
10.1016/j.net.2019.01.002
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The increase of the alternate current frequency results in increased rotational speed of the electrical motors and connected pumps. The consequence for the reactor coolant pumps is increased flow in primary coolant system. Increase of the current frequency can be initiated by the subsynchronous resonance phenomenon (SSR). This paper analyses the implications of the SSR and consequential increase of the frequency on the nuclear power plant safety. The Simulink MATLAB (R) model of the steam turbine and governor system and RELAP5 computer code of the pressurized water reactor are used in the analysis. The SSR results in fast increase of reactor coolant pumps speed and flow in the primary coolant system. The turbine trip value is reached in short time following SSR. The increase of flow of reactor coolant pumps results in increase of heat removal from reactor core. This results in positive reactivity insertion with reactor power increase of 0.5% before reactor trip is initiated by the turbine trip. The main parameters of the plant did not exceed the values of reactor trip set points. The pressure drop over reactor core is small discarding the possibility of core barrel lift. (C) 2019 Korean Nuclear Society, Published by Elsevier Korea LLC.
引用
收藏
页码:1017 / 1023
页数:7
相关论文
共 50 条
  • [21] Nuclear Electric Power Generation. Reliability and Safety.
    Girard, Y.
    Gaussot, D.
    Annales des Mines, 1974, : 13 - 20
  • [22] Subsynchronous resonance and its mitigation for power system with unified power flow controller
    Zhu, Xinyao
    Jin, Meng
    Kong, Xiangping
    Zhao, Jingbo
    Liu, Jiankun
    Zhou, Qian
    JOURNAL OF MODERN POWER SYSTEMS AND CLEAN ENERGY, 2018, 6 (01) : 181 - 189
  • [23] On the effect of AVR gain on bifurcations of subsynchronous resonance in power systems
    Widyan, Mohammad S.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2010, 32 (06) : 656 - 663
  • [24] Effect of exciter and power system stabilizer on subsynchronous resonance damping
    Zhang, Fan
    Xu, Zheng
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2007, 22 (06): : 121 - 127
  • [25] Simulation of Power Plant Subsynchronous Resonance Possibility Based on ADPSS
    Li, Xiaomeng
    Wang, Hua
    Zhang, Zhenan
    Liu, Min
    Xu, Dechao
    ADVANCES IN COMPUTATIONAL MODELING AND SIMULATION, PTS 1 AND 2, 2014, 444-445 : 932 - +
  • [26] DAMPING SUBSYNCHRONOUS RESONANCE USING REACTIVE POWER-CONTROL
    WASYNCZUK, O
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1981, 100 (03): : 1096 - 1104
  • [27] Analysis of subsynchronous resonance with generalized unified power flow controller
    Thirumalaivasan, R.
    Prabhu, Nagesh
    Janaki, M.
    Kothari, D. P.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2013, 53 : 623 - 631
  • [28] Subsynchronous resonance and its mitigation for power system with unified power flow controller
    Xinyao ZHU
    Meng JIN
    Xiangping KONG
    Jingbo ZHAO
    Jiankun LIU
    Qian ZHOU
    Journal of Modern Power Systems and Clean Energy, 2018, 6 (01) : 181 - 189
  • [30] Identification of Subsynchronous Oscillations by Bandpass Filtering of Power System Frequency
    Hwang, Jin Kwon
    Kim, Yong-Hak
    2020 IEEE 4TH INTERNATIONAL CONFERENCE ON INTELLIGENT ENERGY AND POWER SYSTEMS (IEPS), 2020, : 15 - 19