Electric power frequency and nuclear safety - Subsynchronous resonance case study

被引:2
|
作者
Volkanovski, Andrija [1 ]
Prosek, Andrej [1 ]
机构
[1] Jozef Stefan Inst, Reactor Engn Div R4, Jamova Cesta 39, SI-1000 Ljubljana, Slovenia
关键词
Subsynchronous resonance; Reactor coolant pumps; RELAP5; STATION BLACKOUT; REACTOR; SYSTEM; MITIGATION;
D O I
10.1016/j.net.2019.01.002
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The increase of the alternate current frequency results in increased rotational speed of the electrical motors and connected pumps. The consequence for the reactor coolant pumps is increased flow in primary coolant system. Increase of the current frequency can be initiated by the subsynchronous resonance phenomenon (SSR). This paper analyses the implications of the SSR and consequential increase of the frequency on the nuclear power plant safety. The Simulink MATLAB (R) model of the steam turbine and governor system and RELAP5 computer code of the pressurized water reactor are used in the analysis. The SSR results in fast increase of reactor coolant pumps speed and flow in the primary coolant system. The turbine trip value is reached in short time following SSR. The increase of flow of reactor coolant pumps results in increase of heat removal from reactor core. This results in positive reactivity insertion with reactor power increase of 0.5% before reactor trip is initiated by the turbine trip. The main parameters of the plant did not exceed the values of reactor trip set points. The pressure drop over reactor core is small discarding the possibility of core barrel lift. (C) 2019 Korean Nuclear Society, Published by Elsevier Korea LLC.
引用
收藏
页码:1017 / 1023
页数:7
相关论文
共 50 条
  • [1] A Comparison of Different Frequency Scanning Methods for Study of Subsynchronous Resonance
    Johansson, Nicklas
    Angquist, Lennart
    Nee, Hans-Peter
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2011, 26 (01) : 356 - 363
  • [2] Damping subsynchronous resonance in power systems
    Gupta, SK
    Gupta, AK
    Kumar, N
    [J]. IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2002, 149 (06) : 679 - 688
  • [3] Simulation and mitigation of subsynchronous resonance in power systems
    Varela, Jorge
    Parada, Miguel
    [J]. 2021 IEEE IFAC INTERNATIONAL CONFERENCE ON AUTOMATION/XXIV CONGRESS OF THE CHILEAN ASSOCIATION OF AUTOMATIC CONTROL (IEEE IFAC ICA - ACCA2021), 2021,
  • [4] SHIFT OF NUCLEAR QUADRUPOLE RESONANCE FREQUENCY BY ELECTRIC FIELD
    KUSHIDA, T
    SAIKI, K
    [J]. PHYSICAL REVIEW LETTERS, 1961, 7 (01) : 9 - &
  • [5] USE OF FREQUENCY SCANNING TECHNIQUES FOR SUBSYNCHRONOUS RESONANCE ANALYSIS
    AGRAWAL, BL
    FARMER, RG
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1979, 98 (02): : 341 - 349
  • [6] BIBLIOGRAPHY FOR STUDY OF SUBSYNCHRONOUS RESONANCE BETWEEN ROTATING MACHINES AND POWER-SYSTEMS
    不详
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1976, 95 (01): : 216 - 218
  • [7] THEORETICAL-STUDY OF A SHUNT REACTOR SUBSYNCHRONOUS RESONANCE STABILIZER FOR A NUCLEAR POWERED GENERATOR
    LAHOUD, MA
    HARLEY, RG
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 1985, 8 (03) : 261 - 274
  • [8] Nuclear Spin Resonance Induced by Radio Frequency Electric Field
    Kumada, N.
    Kamada, T.
    Hirayama, Y.
    Miyashita, S.
    Fujisawa, T.
    [J]. PHYSICS OF SEMICONDUCTORS, 2009, 1199 : 461 - +
  • [9] Review of measures to mitigate subsynchronous resonance in power systems
    Tian, Xu
    Jiang, Qirong
    Xie, Xiaorong
    [J]. Dianwang Jishu/Power System Technology, 2010, 34 (12): : 74 - 79
  • [10] STABILIZATION OF SUBSYNCHRONOUS RESONANCE OSCILLATIONS BY REACTIVE POWER MODULATION
    HAMDAN, HMA
    [J]. ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 1989, 14 (03): : 413 - 424