Highly sensitive quartz crystal microbalance based biosensor using Au dendrite structure

被引:4
|
作者
Asai, Naoto [1 ]
Terasawa, Hideaki [1 ]
Shimizu, Tomohiro [1 ]
Shingubara, Shoso [1 ]
Ito, Takeshi [1 ]
机构
[1] Kansai Univ, Grad Sch Sci & Engn, Suita, Osaka 5648680, Japan
关键词
ELECTROCHEMICAL BIOSENSOR; FREQUENCY; NANOTUBES; ASSAY;
D O I
10.7567/JJAP.57.02CD01
中图分类号
O59 [应用物理学];
学科分类号
摘要
A Au dendrite structure was obtained by only electroplating under a suitable potential. A blanch like nanostructure was formed along the crystal orientation. In this study, we attempted to fabricate a Au dendrite structure on the electrode of a quartz crystal by electroplating to increase the specific surface area. We estimated the effective surface area by cyclic voltammetry (CV) and monitored the frequency shift induced by antigen-antibody interaction by the quartz crystal microbalance (QCM) method. The dendrite structure with the largest surface area was formed under -0.95V for 5 min. In the measurement of the antigen-antibody interaction, the frequency shifts of 40, 80, and 110Hz were obtained with the dendrite structured QCM chips formed at the above potential for 1, 1.5, and 2.0 min, respectively. The sensitivity was improved compared with that QCM chip having a flat surface electrode. (C) 2018 The Japan Society of Applied Physics
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Aptamer-based piezoelectric quartz crystal microbalance biosensor array for the quantification of IgE
    Yao, Chunyan
    Qi, Yongzhi
    Zhao, Yuhui
    Xiang, Yang
    Chen, Qinghai
    Fu, Weiling
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (08): : 2499 - 2503
  • [42] Diagnosis and genotyping of Plasmodium falciparum by a DNA biosensor based on quartz crystal microbalance (QCM)
    Potipitak, Tiparat
    Ngrenngarmlert, Warunee
    Promptmas, Chamras
    Chomean, Sirinart
    Ittarat, Wanida
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 (08) : 1367 - 1373
  • [43] Quartz crystal microbalance-based biosensor for the detection of α-thalassemia 1 (SEA deletion)
    Chomean, Sirinart
    Potipitak, Tiparat
    Promptmas, Chamras
    Ittarat, Wanida
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2010, 48 (09) : 1247 - 1254
  • [44] Immunosensors using a quartz crystal microbalance
    Kurosawa, S
    Aizawa, H
    Tozuka, M
    Nakamura, M
    Park, JW
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2003, 14 (11) : 1882 - 1887
  • [45] Quartz crystal microbalance study of the specific adsorption of halide anions on highly ordered Au(111)
    Uchida, H
    Lei, HW
    Hiei, M
    Watanabe, M
    PROCEEDINGS OF THE SIXTH INTERNATIONAL SYMPOSIUM ON ELECTRODE PROCESSES, 1996, 96 (08): : 83 - 95
  • [46] Construction of a novel macroporous imprinted biosensor based on quartz crystal microbalance for ribonuclease A detection
    Liu, Shuai
    Zhou, Dezhong
    Guo, Tianying
    BIOSENSORS & BIOELECTRONICS, 2013, 42 : 80 - 86
  • [47] A reusable quartz crystal microbalance biosensor for highly specific detection of single-base DNA mutation
    Wang, Dingzhong
    Chen, Gengjia
    Wang, Huaming
    Tang, Wei
    Pan, Wei
    Li, Na
    Liu, Feng
    BIOSENSORS & BIOELECTRONICS, 2013, 48 : 276 - 280
  • [48] Flow-injection assay of the pathogenic bacteria using lectin-based quartz crystal microbalance biosensor
    Safina, Gulnara
    van Lier, Margret
    Danielsson, Bengt
    TALANTA, 2008, 77 (02) : 468 - 472
  • [49] Replacement-Free Electrodeless Quartz Crystal Microbalance Biosensor Using Nonspecific-Adsorption of Streptavidin on Quartz
    Ogi, Hirotsugu
    Okamoto, Ken
    Nagai, Hironao
    Fukunishi, Yuji
    Hirao, Masahiko
    ANALYTICAL CHEMISTRY, 2009, 81 (10) : 4015 - 4020
  • [50] An aptamer-based quartz crystal microbalance biosensor for sensitive and selective detection of leukemia cells using silver-enhanced gold nanoparticle label
    Shan, Wenqian
    Pan, Yuliang
    Fang, Heting
    Guo, Manli
    Nie, Zhou
    Huang, Yan
    Yao, Shouzhuo
    TALANTA, 2014, 126 : 130 - 135