Intraocular pressure after descemet stripping endothelial keratoplasty (DSEK)

被引:11
|
作者
Nieuwendaal, Carla P.
van der Meulen, Ivanka J. E.
Lapid-Gortzak, Ruth
Mourits, Maarten P.
机构
[1] Department of Ophthalmology, Academic Medical Center, Meibergdreef 9
关键词
POSTERIOR LAMELLAR KERATOPLASTY; GRAFT FAILURE; GLAUCOMA; EYES;
D O I
10.1007/s10792-012-9665-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To assess the incidence of elevated intraocular pressure (IOP) after descemet stripping endothelial keratoplasty (DSEK). Retrospective case series. From the start of the technique in our hospital in 2003 until the middle of 2010, 73 eyes underwent DSEK, of which 66 (90.5 %) had a clear graft 1 year after surgery. IOP data pre- and postoperatively were analyzed. Follow-up was 1-5 years (mean 3.8, SD 1.3). Mean age was 71 years (SD 11, range 43-89). Three eyes (4.5 %) had a history of glaucoma before DSEK. Mean pre-operative IOP was 12.4 mmHg (SD +/- A 4.3). Mean IOP 1 day post-operatively was 16.4 mmHg (+/- 9.2). Mean IOP after 1 and 6 months, and 1, 3, and 5 years were, respectively, 13.9 (+/- 5.3), 14.7 (+/- 5.6), 14.2 (+/- 5.4), 13.8 (+/- 3.7), and 12.6 (+/- 3.5). Seventeen percent (11 eyes) had a postoperative rise in IOP which needed medical or surgical intervention: 8 % (5 eyes) had a rise in IOP 1 day after DSEK, of which 1 underwent a trabeculectomy 7 months after DSEK surgery; 6 % (4 eyes) had a rise in IOP later in the postoperative period, which could all be managed medically; and 3 % (2 eyes) had increased IOP 1 day after DSEK and later in the postoperative period, both eyes underwent a trabeculectomy 5 and 24 months, respectively, after DSEK surgery. An increase in IOP was encountered in 17 % of DSEK patients. Checking the IOP in the short and long postoperative period is necessary.
引用
收藏
页码:147 / 151
页数:5
相关论文
共 50 条
  • [41] Intraocular Lens Exchange 1 Week After Descemet Stripping Automated Endothelial Keratoplasty
    Lapenna, Lucia
    Kadyan, Anju
    Busin, Massimo
    CORNEA, 2010, 29 (02) : 207 - 209
  • [42] DESCEMET STRIPPING ENDOTHELIAL KERATOPLASTY IN EYES WITH ENDOTHELIAL DECOMPENSATION AFTER PENETRATING KERATOPLASTY
    Beltz, Jacqueline
    Busin, Massimo
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 41 : 34 - 34
  • [43] Descemet Membrane Endothelial Keratoplasty as Treatment for Graft Failure After Descemet Stripping Automated Endothelial Keratoplasty
    Weller, Julia M.
    Tourtas, Theofilos
    Kruse, Friedrich E.
    Schloetzer-Schrehardt, Ursula
    Fuchsluger, Thomas
    Bachmann, Bjoern O.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2015, 159 (06) : 1050 - 1057
  • [44] Outcome of Descemet membrane endothelial keratoplasty for graft failure after Descemet stripping automated endothelial keratoplasty
    Agha, Bishr
    Shajari, Mehdi
    Slavik-Lencova, Anna
    Kohnen, Thomas
    Schmack, Ingo
    CLINICAL OPHTHALMOLOGY, 2019, 13 : 553 - 559
  • [45] Outcomes of rebubbling for graft detachment after Descemet's stripping endothelial keratoplasty or Descemet's stripping automated endothelial keratoplasty
    Bhalerao, Sushank A.
    Mohamed, Ashik
    Vaddavalli, Pravin K.
    Murthy, Somasheila, I
    Reddy, Jagadesh C.
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (01) : 48 - 53
  • [46] Cataract surgery after Descemet stripping endothelial keratoplasty
    Chaurasia, Sunita
    Ramappa, Muralidhar
    Sangwan, Virender
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2012, 60 (06) : 572 - U146
  • [47] Complications after Descemet's stripping endothelial keratoplasty
    Moura, Gustavo Souza
    Peixoto de Oliveira, Grazielly Martins
    Tognon, Taise
    Pereira, Nicolas Cesario
    de Sousa, Luciene Barbosa
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2013, 76 (05) : 288 - 291
  • [48] Endothelial Keratoplasty Without Descemet Stripping After Failed Penetrating Keratoplasty
    de Paula, Fernando Heitor
    Kamyar, Roheena
    Shtein, Roni M.
    Sugar, Alan
    Mian, Shahzad I.
    CORNEA, 2012, 31 (06) : 645 - 648
  • [49] Descemet Stripping Automated Endothelial Keratoplasty After Failed Penetrating Keratoplasty
    Jangi, Anisha A.
    Ritterband, David C.
    Wu, Elaine I.
    Mehta, Veeral V.
    Koplin, Richard S.
    Seedor, John A.
    CORNEA, 2012, 31 (10) : 1148 - 1153
  • [50] Early Intraocular Pressure, Corneal and Anterior Chamber Changes After Descemet's Stripping Automated Endothelial Keratoplasty (DSAEK)
    Di Pascuale, M. A.
    Pessach, Y.
    Mootha, V. V.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)