Measurement of innate immune response biomarkers in peritoneal dialysis effluent using a rapid diagnostic point-of-care device as a diagnostic indicator of peritonitis

被引:23
|
作者
Goodlad, Catriona [1 ]
George, Sophiamma [1 ]
Sandoval, Shella [1 ]
Mepham, Stephen [1 ]
Parekh, Gita [2 ]
Eberl, Matthias [3 ,4 ]
Topley, Nicholas [5 ]
Davenport, Andrew [1 ,6 ]
机构
[1] Royal Free Hosp, Dept Nephrol, Pond St, London NW3 2QG, England
[2] Mologic Inc, Thurleigh, Beds, England
[3] Cardiff Univ, Sch Med, Div Infect & Immun, Cardiff, Wales
[4] Cardiff Univ, Syst Immun Res Inst, Cardiff, Wales
[5] Cardiff Univ, Sch Med, Wales Kidney Res Unit, Cardiff, Wales
[6] UCL, Ctr Nephrol, London, England
关键词
biomarkers; infection diagnosis; peritoneal dialysis; peritonitis; point-of-care; INFLAMMATION; INTERLEUKIN-6; RECOMMENDATIONS; FINGERPRINTS; INFECTION; IL-6;
D O I
10.1016/j.kint.2020.01.044
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Peritonitis is the commonest complication of peritoneal dialysis and a major reason for treatment failure. Current diagnosis is based on clinical symptoms, cloudy effluent and a dialysate white cell count (over 100 cells/ml). A rapid point-of-care diagnostic test would accelerate diagnosis and potentially improve outcomes from infection. Here, in a clinical audit project, we used PERiPLEX (R), a point-of-care device which detects when levels of matrix metalloproteinase-8 and interleukin-6 are elevated above a threshold within minutes in dialysis effluent, to assess whether it could confirm or exclude peritonitis in 107 patients undergoing peritoneal dialysis. Mean patient age was 64.6 years with a median duration of peritoneal dialysis of 13.3 months (interquartile range 6.3 - 33.5 months). Presence of peritonitis was confirmed by clinical criteria. There were 49 positive tests of which 41 patients had peritonitis, three had other causes of intra-peritoneal inflammation, three had severe urosepsis and two patients required no treatment. Fifty-eight tests were negative with one patient having a false negative result. The positive predictive value of the test was 83.7% (95% confidence interval 72.8 - 90.8) and the negative predictive value was 98.3% (89.1 - 99.8). Sensitivity and specificity were 97.6% (87.4 - 99.9) and 87.7% (77.2 - 94.5) respectively. Thus, PERiPLEX (R) could be used as a rapid point-of-care test that can aid the diagnosis or exclusion of peritonitis with a high negative predictive value.
引用
收藏
页码:1253 / 1259
页数:7
相关论文
共 25 条
  • [21] Evaluation of a rapid antigen detection test (Panbio™ COVID-19 Ag Rapid Test Device) as a point-of-care diagnostic tool for COVID-19 in a pediatric emergency department
    Carbonell-Sahuquillo, Silvia
    Lazaro-Carreno, Maria I.
    Camacho, Jorge
    Barres-Fernandez, Ana
    Albert, Eliseo
    Torres, Ignacio
    Breton-Martinez, Jose R.
    Martinez-Costa, Cecilia
    Navarro, David
    JOURNAL OF MEDICAL VIROLOGY, 2021, 93 (12) : 6803 - 6807
  • [22] Development of Aptamer-Functionalized Gold Nanoparticles as Probes in Point-of-Care Diagnostic Device for Rapid Detection of Multidrug-Resistant Bacteria in Bombyx mori L.
    Mondal, Rittick
    Chakraborty, Joydeep
    Dam, Paulami
    Shaw, Shubhajit
    Gangopadhyay, Debnirmalya
    Ertas, Yavuz Nuri
    Mandal, Amit Kumar
    ACS APPLIED BIO MATERIALS, 2024, 7 (08): : 5740 - 5753
  • [23] Point-of-care diagnostic (POCD) method for detecting Bursaphelenchus xylophilus in pinewood using recombinase polymerase amplification (RPA) with the portable optical isothermal device (POID)
    Cha, Deokjea
    Kim, Dongsoo
    Choi, Wonil
    Park, Sungjun
    Han, Hyerim
    PLOS ONE, 2020, 15 (01):
  • [24] Facile and Compact Electrochemical Paper-Based Analytical Device for Point-of-Care Diagnostic of Dual Carcinogen Oxidative Stress Biomarkers through a Molecularly Imprinted Polymer Coated on Quantum-Dot Gold
    Amatatongchai, Maliwan
    Nontawong, Nongyao
    Ngaosri, Pattanun
    Chunta, Suticha
    Wanram, Surasak
    Jarujamrus, Purim
    Nacapricha, Duangjai
    Lieberzeit, Peter A.
    ANALYTICAL CHEMISTRY, 2022, 94 (48) : 16692 - 16700
  • [25] Diagnostic accuracy of a machine learning algorithm using point-of-care high-sensitivity cardiac troponin I for rapid rule-out of myocardial infarction: a retrospective study
    Toprak, Betuel
    Solleder, Hugo
    Di Carluccio, Eleonora
    Greenslade, Jaimi H.
    Parsonage, William A.
    Schulz, Karen
    Cullen, Louise
    Apple, Fred S.
    Ziegler, Andreas
    Blankenberg, Stefan
    LANCET DIGITAL HEALTH, 2024, 6 (10): : E729 - E738