In situ static and dynamic investigations on the "Torre Grossa" masonry tower

被引:105
|
作者
Bartoli, Gianni [1 ]
Betti, Michele [1 ]
Giordano, Saverio [1 ]
机构
[1] Univ Florence, Dept Civil & Environm Engn DICeA, I-50139 Florence, Italy
关键词
Historical masonry tower; In situ non-destructive tests; Experimental analysis; FEM identification; Structural identification; BELL TOWER; DAMAGE ASSESSMENT; IDENTIFICATION; FAILURE; DOME;
D O I
10.1016/j.engstruct.2013.01.030
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Many ancient masonry towers represent one of the most relevant characteristics of both the Italian and the whole European territory. To preserve their cultural and economic Value, they often call for a deeper investigation to assess their state of conservation. This paper offers a contribution to the issue of monitoring and analysis of monumental masonry tower, by discussing an experimental investigation survey made on an illustrative masonry tower: the Italian Medieval "Torre Grossa" (Big Tower) of San Gimignano in Toscana (Italy). The tower is part of the UNESCO cultural heritage after 1990 together with the city centre; it dates back to the thirteenth century and its height is about 55 m (one of the tallest masonry tower in Italy) with a square cross-section whose side is about 9.5 m. During the experimental campaign, both static and dynamic tests were performed. Static tests (flat-jack and laboratory test on cored specimens) were used to estimate the mechanical properties and the ultimate strength of masonry. Dynamic tests led to the measurements of the natural frequencies and corresponding modal shapes of the whole monument. By using the finite element technique, a 3D model of the tower was built (macro-modelling) and it was calibrated on the basis of the in situ investigation survey; the degree of restrain offered by the neighbouring buildings was estimated by tuning the numerical results with those obtained from the dynamic tests. The paper, by discussing the design and results of the experimental campaign, aims at offering a contribution to both the investigation and the structural behaviour of historic masonry towers providing useful hints to deepen the knowledge on their structural behaviour. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:718 / 733
页数:16
相关论文
共 50 条
  • [1] Dynamic investigations on a masonry bell tower
    Ivorra, S
    Pallarés, FJ
    [J]. ENGINEERING STRUCTURES, 2006, 28 (05) : 660 - 667
  • [2] Dynamic investigations and strengthening on masonry bell tower
    Kouris, S. S.
    Karaveziroglou-Weber, M.
    [J]. PROTECTION OF HISTORICAL BUILDINGS - PROHITECH 09, VOL 1 AND 2, 2009, : 941 - 947
  • [3] Earthquake protection of the Torre Grossa medieval tower of San Gimignano, Italy by vertical external prestressing
    Preciado, Adolfo
    Bartoli, Gianni
    Ramirez-Gaytan, Alejandro
    [J]. ENGINEERING FAILURE ANALYSIS, 2017, 71 : 31 - 42
  • [4] DYNAMIC MONITORING OF A MASONRY TOWER
    Gentile, Carmelo
    Saisi, Antonella
    Cabboi, Alessandro
    [J]. STRUCTURAL ANALYSIS OF HISTORICAL CONSTRUCTIONS, VOLS 1-3, 2012, : 2390 - +
  • [5] The dynamic behaviour of a historical bell tower - in-situ tests and numerical investigations
    Zabel, V
    Bucher, C
    Riedel, J
    [J]. NOISE AND VIBRATION ENGINEERING, VOLS 1 - 3, PROCEEDINGS, 2001, : 365 - 372
  • [6] In-situ and laboratory investigations on materials and structures for the static improvement: "Torre Quadrata del Circo Romano" (Milan)
    Bortolotto, Susanna
    Ciocchini, Elisabetta
    Zangheri, Fabio
    De Marchi, Paola Marina
    [J]. STRUCTURAL ANALYSIS OF HISTORIC CONSTRUCTION: PRESERVING SAFETY AND SIGNIFICANCE, VOLS 1 AND 2, 2008, : 481 - +
  • [7] SEISMIC ASSESSMENT OF A MEDIEVAL MASONRY TOWER IN NORTHERN ITALY BY LIMIT, NONLINEAR STATIC, AND FULL DYNAMIC ANALYSES
    Milani, Gabriele
    Casolo, Siro
    Naliato, Andrea
    Tralli, Antonio
    [J]. INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE, 2012, 6 (05) : 489 - 524
  • [8] Seismic assessment of a historical masonry tower with nonlinear static and dynamic analyses tuned on ambient vibration tests
    D'Ambrisi, Angelo
    Mariani, Valentina
    Mezzi, Marco
    [J]. ENGINEERING STRUCTURES, 2012, 36 : 210 - 219
  • [9] One-year dynamic monitoring of a masonry tower
    Guidobaldi, Marco
    Gentile, Carmelo
    Saisi, Antonella
    [J]. EVACES'15, 6TH INTERNATIONAL CONFERENCE ON EXPERIMENTAL VIBRATION ANALYSIS FOR CIVIL ENGINEERING STRUCTURES, 2015, 24
  • [10] Dynamic and seismic health monitoring of a historic masonry tower
    Saisi, Antonella
    Gentile, Carmelo
    Guidobaldi, Marco
    [J]. Ingegneria Sismica, 2014, 31 (03):