A pictorial view of the three-dimensional representation and comparative two-dimensional image orientation derived from computed tomography angiography in a dog with a patent ductus arteriosus

被引:4
|
作者
Saunders, A. B. [1 ]
Doocy, K. R. [1 ]
Birch, S. A. [2 ]
机构
[1] Texas A&M Univ, Dept Small Anim Clin Sci, College Stn, TX 77843 USA
[2] PixelBeaker, Chattanooga, TN USA
关键词
Canine; Congenital; Echocardiography; OCCLUSION; CLOSURE;
D O I
10.1016/j.jvc.2018.09.004
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Patent ductus arteriosus (PDA) occlusion is one of the more common cardiovascular procedures performed in dogs. Two-dimensional imaging has been the primary method of visualizing the PDA and is the basis of its morphologic description. Transesophageal echocardiographic imaging has further characterized the three-dimensional (3D) variation in ductal morphology and shape (circle, oval). An accurate assessment of the shape and dimensions of a PDA in an individual dog is important when making decisions about definitive closure. Ductal measurements from angiography and echocardiography have not been found to be interchangeable, likely related in part to the static two-dimensional measurement of a 3D structure. We describe the use of computed tomography angiography (CTA) images imported into three software programs as a tool to provide 3D information about PDA anatomy including a comparison to images obtained from classic two-dimensional imaging modalities. These images provide an example of thorax and heart position related to transducer position and the orientation of image acquisition to demonstrate why measurements do not always compare. Additionally, 3D images are useful as a training tool and in the development of devices and training opportunities. Multidimensional imaging provides a unique representation of the 3D anatomical structure of the ductus arteriosus as displayed in these images from a dog with a PDA. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:34 / 40
页数:7
相关论文
共 50 条
  • [21] Detection of intracranial aneurysms with two-dimensional and three-dimensional multislice helical computed tomographic angiography - Comments
    Solomon, RA
    Satow, T
    Hashimoto, N
    Seifert, V
    Beck, J
    Hoh, BL
    Ogilvy, CS
    NEUROSURGERY, 2004, 54 (02) : 340 - 341
  • [22] Left atrial volumes: two-dimensional, three-dimensional, cardiac magnetic resonance and computed tomography measurements
    Boyd, Anita C.
    Thomas, Liza
    CURRENT OPINION IN CARDIOLOGY, 2014, 29 (05) : 408 - 416
  • [23] Quantitative computed tomography of spine -: Comparison of three-dimensional and two-dimensional imaging approaches in clinical practice
    Theodorou, DJ
    Theodorou, SJ
    André, MP
    Kubota, D
    Weigert, JM
    Sartoris, DJ
    JOURNAL OF CLINICAL DENSITOMETRY, 2001, 4 (01) : 57 - 62
  • [24] Three-Dimensional Reconstruction of Two-Dimensional Cardiovascular Angiography Image Sequences by Local Threshold Segmentation Algorithm
    Yu, Shenming
    SCIENTIFIC PROGRAMMING, 2022, 2022
  • [25] Determination of three-dimensional flamelet orientation distributions in turbulent V-flames from two-dimensional image data
    Sattler, SS
    Knaus, DA
    Gouldin, FC
    PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2002, 29 (02) : 1785 - 1792
  • [26] Clinical Validation of the Differences Between Two-Dimensional Radiography and Three-Dimensional Computed Tomography Image Measurements of the Spine in Adolescent Idiopathic Scoliosis
    Zhang, Mingzheng
    Chen, Wenxuan
    Wang, Shengru
    Lei, Siao
    Liu, Yuchen
    Zhang, Jianguo
    Pu, Fang
    WORLD NEUROSURGERY, 2022, 165 : E689 - E696
  • [27] Image Guidance for Endovascular Repair of Complex Aortic Aneurysms: Comparison of Two-dimensional and Three-dimensional Angiography and Image Fusion
    Tacher, Vania
    De Lin, Ming
    Desgranges, Pascal
    Deux, Jean-Francois
    Grunhagen, Thijs
    Becquemin, Jean-Pierre
    Luciani, Alain
    Rahmouni, Alain
    Kobeiter, Hicham
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2013, 24 (11) : 1698 - 1706
  • [28] Comparative Assessment of the Efficacy of Two-Dimensional Digital Intraoral Radiography to Three-Dimensional Cone Beam Computed Tomography in the Diagnosis of Periapical Pathologies
    Surya, S.
    Barua, Akash Narayan Dutta
    Magar, Shaliputra Pralhad
    Magar, Shilpa Shaliputra
    Rela, Rathi
    Chhabada, Amarpal Kour
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2022, 14 : 1009 - 1013
  • [29] Two- and three-dimensional transesophageal echocardiographic assessment and successful occlusion of a window-like patent ductus arteriosus in two dogs
    Craciun, I.
    Silva, J.
    Dutton, L. C.
    Loureiro, J.
    Matos, J. Novo
    JOURNAL OF VETERINARY CARDIOLOGY, 2024, 51 : 214 - 219
  • [30] Three-Dimensional Echocardiographic Deconstruction: Feasibility of Clinical Evaluation from Two-Dimensional Views Derived from a Three-Dimensional Data Set
    Henry, Michael P.
    Cotella, Juan, I
    Slivnick, Jeremy A.
    Yamat, Megan
    Hipke, Kyle
    Johnson, Roydell
    Mor-Avi, Victor
    Lang, Roberto M.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2022, 35 (10) : 1009 - +