A pictorial view of the three-dimensional representation and comparative two-dimensional image orientation derived from computed tomography angiography in a dog with a patent ductus arteriosus

被引:4
|
作者
Saunders, A. B. [1 ]
Doocy, K. R. [1 ]
Birch, S. A. [2 ]
机构
[1] Texas A&M Univ, Dept Small Anim Clin Sci, College Stn, TX 77843 USA
[2] PixelBeaker, Chattanooga, TN USA
关键词
Canine; Congenital; Echocardiography; OCCLUSION; CLOSURE;
D O I
10.1016/j.jvc.2018.09.004
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Patent ductus arteriosus (PDA) occlusion is one of the more common cardiovascular procedures performed in dogs. Two-dimensional imaging has been the primary method of visualizing the PDA and is the basis of its morphologic description. Transesophageal echocardiographic imaging has further characterized the three-dimensional (3D) variation in ductal morphology and shape (circle, oval). An accurate assessment of the shape and dimensions of a PDA in an individual dog is important when making decisions about definitive closure. Ductal measurements from angiography and echocardiography have not been found to be interchangeable, likely related in part to the static two-dimensional measurement of a 3D structure. We describe the use of computed tomography angiography (CTA) images imported into three software programs as a tool to provide 3D information about PDA anatomy including a comparison to images obtained from classic two-dimensional imaging modalities. These images provide an example of thorax and heart position related to transducer position and the orientation of image acquisition to demonstrate why measurements do not always compare. Additionally, 3D images are useful as a training tool and in the development of devices and training opportunities. Multidimensional imaging provides a unique representation of the 3D anatomical structure of the ductus arteriosus as displayed in these images from a dog with a PDA. (C) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:34 / 40
页数:7
相关论文
共 50 条
  • [1] The diagnosis of patent ductus arteriosus with Eisenmenger's syndrome by three-dimensional computed tomography: A case report
    Yilmaz, R
    Demirbag, R
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2005, 105 (01) : 96 - 97
  • [2] Two-Dimensional Versus Three-Dimensional Computed Tomography
    Wiwanitkit, Viroj
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2010, 35A (03): : 513 - 513
  • [3] Regression of ductus arteriosus aneurysm in a neonate demonstrated by three-dimensional computed tomography
    Lee, WJ
    Chen, SJ
    Wu, MH
    Li, YW
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1999, 68 (02) : 231 - 234
  • [4] Three-dimensional rotational digital angiography in a complicated case of patent ductus arteriosus transcatheter closure
    Rigatelli, Gianluca
    Zamboni, Alberto
    Cardaioli, Paolo
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 70 (06) : 900 - 903
  • [5] Comparison of two-dimensional imaging to three-dimensional modeling of intrahepatic portosystemic shunts using computed tomography angiography
    Jackson, Erin
    Markovic, Lauren E.
    Perlini, Michael
    VETERINARY RADIOLOGY & ULTRASOUND, 2024, 65 (02) : 130 - 137
  • [6] Three-dimensional joint surface orientation does not correlate with two-dimensional coronal joint line orientation in knee osteoarthritis: Three-dimensional analysis of upright computed tomography
    Sasaki, Ryo
    Niki, Yasuo
    Kaneda, Kazuya
    Yamada, Yoshitake
    Nagura, Takeo
    Nakamura, Masaya
    Jinzaki, Masahiro
    KNEE, 2023, 43 : 10 - 17
  • [7] Comparing the feasibility and accuracy of three-dimensional ultrasound to two-dimensional ultrasound and computed tomography angiography in the assessment of carotid atherosclerosis
    Song, Shinjeong
    Heo, Ran
    Lee, Sang-Eun
    Park, Jinki
    Lee, Jinyong
    Kim, Sujin
    Cho, In Jeong
    Chang, Hyuk-Jae
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2019, 36 (12): : 2241 - 2250
  • [8] Three-dimensional scene reconstruction from a two-dimensional image
    Parkins, Franz
    Jacobs, Eddie
    GEOSPATIAL INFORMATICS, FUSION, AND MOTION VIDEO ANALYTICS VII, 2017, 10199
  • [9] Evaluation of two-dimensional lateral cephalogram and three-dimensional cone beam computed tomography superimpositions: a comparative study
    Heinz, J.
    Stewart, K.
    Ghoneima, A.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2019, 48 (04) : 519 - 525
  • [10] Two-Dimensional and Three-Dimensional Cephalometry Using Cone Beam Computed Tomography Scans
    Michele, Cassetta
    Federica, Altieri
    Roberto, Di Giorgio
    Alessandro, Silvestri
    JOURNAL OF CRANIOFACIAL SURGERY, 2015, 26 (04) : E311 - E315