Interrater reliability of deep brain stimulation electrode localizations

被引:10
|
作者
Lofredi, Roxanne [1 ,2 ]
Auernig, Cem-Georg [1 ]
Ewert, Siobhan [1 ]
Irmen, Friederike [1 ]
Steiner, Leon A. [1 ,2 ]
Scheller, Ute [1 ,3 ]
van Wijk, Bernadette C. M. [1 ,4 ,5 ]
Oxenford, Simon [1 ]
Kuhn, Andrea A. [1 ,6 ,7 ,8 ,9 ,10 ]
Horn, Andreas [1 ,10 ,11 ,12 ]
机构
[1] Charite Univ Med Berlin, Dept Neurol, Berlin, Germany
[2] Berlin Inst Hlth BIH, Berlin, Germany
[3] Univ Med Gottingen, Dept Neurol, Gottingen, Germany
[4] Vrije Univ Amsterdam, Dept Human Movement Sci, Amsterdam, Netherlands
[5] Univ Amsterdam, Dept Neurol, Med Ctr, Amsterdam, Netherlands
[6] Humboldt Univ, Bernstein Ctr Computat Neurosci, Berlin, Germany
[7] Charite Univ Med Berlin, NeuroCure, Exzellenzcluster, Berlin, Germany
[8] German Ctr Neurodegenerat Dis, DZNE, Berlin, Germany
[9] Humboldt Univ, Berlin Sch Mind & Brain, Berlin, Germany
[10] Harvard Med Sch, Ctr Brain Circuit Therapeut, Dept Neurol, Brigham & Womens Hosp, Boston, MA USA
[11] Harvard Med Sch, MGH Neurosurg, Massachusetts Gen Hosp, MGH Neurol, Boston, MA USA
[12] Harvard Med Sch, Massachusetts Gen Hosp, Ctr Neurotechnol & Neurorecovery CNTR, MGH Neurol, Boston, MA USA
关键词
Parkinson's disease; Deep brain stimulation; Subthalamic nucleus; Lead-DBS; Localization; DBS;
D O I
10.1016/j.neuroimage.2022.119552
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Lead-DBS is an open-source, semi-automatized and widely applied software tool facilitating precise localization of deep brain stimulation electrodes both in native as well as in standardized stereotactic space. While automatized preprocessing steps within the toolbox have been tested and validated in previous studies, the interrater reliability in manual refinements of electrode localizations using the tool has not been objectified so far. Here, we investigate the variance introduced in this processing step by different raters when localizing electrodes based on postoperative CT or MRI. Furthermore, we compare the performance of novel trainees that received a structured training and more experienced raters with an expert user. We show that all users yield similar results with an average difference in localizations ranging between 0.52-0.75 mm with 0.07-0.12 mm increases in variability when using postoperative MRI and following normalization to standard space. Our findings may pave the way toward formal training for using Lead-DBS and demonstrate its reliability and ease-of-use for imaging research in the field of deep brain stimulation.
引用
收藏
页数:6
相关论文
共 50 条
  • [11] Biomechanical Simulation of Electrode Migration for Deep Brain Stimulation
    Bilger, Alexandre
    Dequidt, Jeremie
    Duriez, Christian
    Cotin, Stephane
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION, MICCAI 2011, PT I, 2011, 6891 : 339 - 346
  • [12] Mechanical failure of the electrode wire in deep brain stimulation
    Mohit, AA
    Samii, A
    Slimp, JC
    Goodkin, R
    MOVEMENT DISORDERS, 2002, 17 : S203 - S203
  • [13] Evaluation of a deep brain stimulation electrode for laryngeal pacing
    Katada, Akihiro
    Van Himbergen, Daniel
    Kunibe, Isamu
    Nonaka, Satoshi
    Harabuchi, Yasuaki
    Huang, Shan
    Billante, Cheryl R.
    Zealear, David L.
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2008, 117 (08): : 621 - 629
  • [14] Accuracy of stereotactic electrode placement in deep brain stimulation
    Fiegele, T.
    Sohm, F.
    Bauer, R.
    Anton, J.
    Twerdy, K.
    Eisner, W.
    MOVEMENT DISORDERS, 2006, 21 : S667 - S668
  • [15] Analysis of electrode deformations in deep brain stimulation surgery
    Lalys, Florent
    Haegelen, Claire
    D'albis, Tiziano
    Jannin, Pierre
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2014, 9 (01) : 107 - 117
  • [16] Mechanical failure of the electrode wire in deep brain stimulation
    Mohit, AA
    Samii, A
    Slimp, JC
    Grady, MS
    Goodkin, R
    PARKINSONISM & RELATED DISORDERS, 2004, 10 (03) : 153 - 156
  • [17] Anatomic correlates of deep brain stimulation electrode impedance
    Satzer, David
    Maurer, Eric W.
    Lanctin, David
    Guan, Weihua
    Abosch, Aviva
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2015, 86 (04): : 398 - 403
  • [18] Reliability and Stability of Programming Directional Deep Brain Stimulation
    Karl, J.
    Gill, C.
    Joyce, J.
    Ouyang, B.
    Metman, L. Verhagen
    MOVEMENT DISORDERS, 2020, 35 : S617 - S617
  • [19] Sonographic measurement of deep fascia parameters - Interrater reliability
    Stepankova, Tereza
    Quittkova, Adela
    Cech, Zdenek
    Machac, Stanislav
    SURGICAL AND RADIOLOGIC ANATOMY, 2024, 46 (09) : 1481 - 1489
  • [20] Insertional effect following deep brain stimulation electrode implants
    Campos, Ana Carolina Pinheiro
    Hamani, Clement
    EXPERT REVIEW OF MEDICAL DEVICES, 2024, 21 (09) : 793 - 795