Interrater reliability of deep brain stimulation electrode localizations

被引:10
|
作者
Lofredi, Roxanne [1 ,2 ]
Auernig, Cem-Georg [1 ]
Ewert, Siobhan [1 ]
Irmen, Friederike [1 ]
Steiner, Leon A. [1 ,2 ]
Scheller, Ute [1 ,3 ]
van Wijk, Bernadette C. M. [1 ,4 ,5 ]
Oxenford, Simon [1 ]
Kuhn, Andrea A. [1 ,6 ,7 ,8 ,9 ,10 ]
Horn, Andreas [1 ,10 ,11 ,12 ]
机构
[1] Charite Univ Med Berlin, Dept Neurol, Berlin, Germany
[2] Berlin Inst Hlth BIH, Berlin, Germany
[3] Univ Med Gottingen, Dept Neurol, Gottingen, Germany
[4] Vrije Univ Amsterdam, Dept Human Movement Sci, Amsterdam, Netherlands
[5] Univ Amsterdam, Dept Neurol, Med Ctr, Amsterdam, Netherlands
[6] Humboldt Univ, Bernstein Ctr Computat Neurosci, Berlin, Germany
[7] Charite Univ Med Berlin, NeuroCure, Exzellenzcluster, Berlin, Germany
[8] German Ctr Neurodegenerat Dis, DZNE, Berlin, Germany
[9] Humboldt Univ, Berlin Sch Mind & Brain, Berlin, Germany
[10] Harvard Med Sch, Ctr Brain Circuit Therapeut, Dept Neurol, Brigham & Womens Hosp, Boston, MA USA
[11] Harvard Med Sch, MGH Neurosurg, Massachusetts Gen Hosp, MGH Neurol, Boston, MA USA
[12] Harvard Med Sch, Massachusetts Gen Hosp, Ctr Neurotechnol & Neurorecovery CNTR, MGH Neurol, Boston, MA USA
关键词
Parkinson's disease; Deep brain stimulation; Subthalamic nucleus; Lead-DBS; Localization; DBS;
D O I
10.1016/j.neuroimage.2022.119552
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Lead-DBS is an open-source, semi-automatized and widely applied software tool facilitating precise localization of deep brain stimulation electrodes both in native as well as in standardized stereotactic space. While automatized preprocessing steps within the toolbox have been tested and validated in previous studies, the interrater reliability in manual refinements of electrode localizations using the tool has not been objectified so far. Here, we investigate the variance introduced in this processing step by different raters when localizing electrodes based on postoperative CT or MRI. Furthermore, we compare the performance of novel trainees that received a structured training and more experienced raters with an expert user. We show that all users yield similar results with an average difference in localizations ranging between 0.52-0.75 mm with 0.07-0.12 mm increases in variability when using postoperative MRI and following normalization to standard space. Our findings may pave the way toward formal training for using Lead-DBS and demonstrate its reliability and ease-of-use for imaging research in the field of deep brain stimulation.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Toward clinical use of electrode localizations in deep brain stimulation therapy
    Ewert, S.
    Horn, A.
    Plettig, P.
    Ruch, M.
    Kuehn, A.
    MOVEMENT DISORDERS, 2016, 31 : S14 - S14
  • [2] Lead-DBS: A toolbox for deep brain stimulation electrode localizations and visualizations
    Horn, Andreas
    Kuehn, Andrea A.
    NEUROIMAGE, 2015, 107 : 127 - 135
  • [3] Reliability in deep brain stimulation
    Shill, HA
    Shetter, AG
    IEEE TRANSACTIONS ON DEVICE AND MATERIALS RELIABILITY, 2005, 5 (03) : 445 - 448
  • [4] Deep brain stimulation electrode modeling in rats
    Andree, Andrea
    Li, Ningfei
    Butenko, Konstantin
    Kober, Maria
    Chen, Jia Zhi
    Higuchi, Takahiro
    Fauser, Mareike
    Storch, Alexander
    Ip, Chi Wang
    Kuehn, Andrea A.
    Horn, Andreas
    van Rienen, Ursula
    EXPERIMENTAL NEUROLOGY, 2022, 350
  • [5] Improved Electrode Material for Deep Brain Stimulation
    Petrossians, A.
    Whalen, J. J., III
    Weiland, J. D.
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 1798 - 1801
  • [6] The reliability of Deep Brain Stimulation YouTube videos
    Tripathi, Shashwat
    ReFaey, Karim
    Stein, Rachel
    Calhoun, Breanna J.
    Despart, Amanda N.
    Brantley, Megan C.
    Grewal, Sanjeet S.
    Quinones-Hinojosa, Alfredo
    Wharen, Robert E.
    JOURNAL OF CLINICAL NEUROSCIENCE, 2020, 74 : 202 - 204
  • [7] The impact of the electrode-brain interface on the stimulation effects in deep brain stimulation
    Yousif, N.
    Nandi, D.
    Bain, P. G.
    Bayford, R.
    Liu, X.
    MOVEMENT DISORDERS, 2008, 23 (01) : S115 - S116
  • [8] Electrophysiological confrontation of Lead-DBS-based electrode localizations in patients with Parkinson's disease undergoing deep brain stimulation
    Al Awadhi, Abdullah
    Tyrand, Remi
    Horn, Andreas
    Kibleur, Astrid
    Vincentini, Julia
    Zacharia, Andre
    Burkhard, Pierre R.
    Momjian, Shahan
    Boex, Colette
    NEUROIMAGE-CLINICAL, 2022, 34
  • [9] Carbon Nanotube Yarns for Deep Brain Stimulation Electrode
    Jiang, Changqing
    Li, Luming
    Hao, Hongwei
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2011, 19 (06) : 612 - 616
  • [10] Analysis of electrode deformations in deep brain stimulation surgery
    Florent Lalys
    Claire Haegelen
    Tiziano D’albis
    Pierre Jannin
    International Journal of Computer Assisted Radiology and Surgery, 2014, 9 : 107 - 117