Spray water cooling heat transfer at high temperatures and liquid mass fluxes

被引:147
|
作者
Wendelstorf, J. [1 ]
Spitzer, K. -H. [1 ]
Wendelstorf, R. [1 ]
机构
[1] Tech Univ Clausthal, Inst Met, D-38678 Clausthal Zellerfeld, Germany
关键词
spray water cooling; heat transfer coefficient; full cone nozzle; subcooled liquid; film boiling; continuous casting; hot rolling;
D O I
10.1016/j.ijheatmasstransfer.2008.01.032
中图分类号
O414.1 [热力学];
学科分类号
摘要
Spray water cooling is an important technology used in industry for the cooling of materials from temperatures up to 1800 K. The heat transfer coefficient in the so-called steady film boiling regime is known to be a function of the water impact density. Below a specific surface temperature T-L. the heat transfer coefficient shows a strong dependence oil temperature (Leidenfrost effect). These findings are the results of complex self-organizing two-phase boiling heat transfer phenomena. The heat transfer coefficient was measured by an automated cooling test stand (instationary method) under clean (non-oxidizing) surface conditions. Compared to the common thought, all additional temperature dependency in the high temperature regime was found. The heat transfer from the material to the outflowing spray water is explained by it simple model of the two-phase flow region. From the experimental data, all analytic correlation for the dependence of the heat transfer coefficient 7 as all analytic function of water impact density V-s and temperature Delta T is provided. For water temperatures around 291 K, surface temperatures between 473 and 1373 K, i.e. Delta T > 180 K and water impact densities between V-s = 3 and 30 kg/(m(2) s) the heat transfer coefficient alpha was measured. The spray was produced with full cone nozzles (nu(d) approximate to 13-15 m/s, d(d) approximate to 300-400 mu m). (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4902 / 4910
页数:9
相关论文
共 50 条
  • [41] HEAT AND MASS TRANSFER IN SPRAY DRYING
    DLOUHY, J
    GAUVIN, WH
    AICHE JOURNAL, 1960, 6 (01) : 29 - 34
  • [42] MASS AND HEAT TRANSFER IN SPRAY DRYING
    不详
    BRITISH CHEMICAL ENGINEERING, 1967, 12 (01): : 87 - &
  • [43] Analysis of Direct Liquid-Solid Contact Heat Transfer in Monodispersed Spray Cooling
    Delcorio, Brian
    Choi, Kyung-Jin
    JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 1991, 5 (04) : 613 - 620
  • [44] Experimental Investigation on Heat Transfer Characteristics of Liquid Nitrogen Spray Cooling for Large Area
    Gong, Yu
    Zhao, Jinhong
    Li, Wei
    Ai, Qing
    Gong, Jiaming
    Shuai, Yong
    Sun, Chuang
    ENERGIES, 2023, 16 (01)
  • [45] Enhancement of heat transfer rate of high mass flux spray cooling by ethanol-water and ethanol-tween20-water solution at very high initial surface temperature
    Bhatt, N. H.
    Lily
    Raj, R.
    Varshney, P.
    Pati, A. R.
    Chouhan, D.
    Kumar, A.
    Munshi, B.
    Mohapatra, S. S.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 110 : 330 - 347
  • [46] Measurements of Electrode Temperatures, Heat and Water Fluxes in PEMFCs: Conclusions about Transfer Mechanisms
    Thomas, A.
    Maranzana, G.
    Didierjean, S.
    Dillet, J.
    Lottin, O.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2013, 160 (02) : F191 - F204
  • [47] PHYSICS OF HEAT AND MASS TRANSFER DURING EVAPORATIVE COOLING OF WATER.
    Aref'yev, K.M.
    Averkiyev, A.G.
    Heat transfer. Soviet research, 1979, 11 (05): : 135 - 142
  • [48] Spray Cooling Heat Transfer of a Two-Fluid Spray Atomizer
    Hsieh, Shou-Shing
    Huang, Ching-Feng
    Lin, Jhen
    Chen, Yu-Ru
    ASME JOURNAL OF HEAT AND MASS TRANSFER, 2024, 146 (05):
  • [49] Transient Heat Transfer Study of Direct Contact Condensation of Steam in Spray Cooling Water
    Wang Y.
    Hu Y.
    Huang Q.
    Cui Y.
    Transactions of Tianjin University, 2018, 24 (2) : 131 - 143
  • [50] Transient Heat Transfer Study of Direct Contact Condensation of Steam in Spray Cooling Water
    Yiping Wang
    Yunfa Hu
    Qunwu Huang
    Yong Cui
    Transactions of Tianjin University, 2018, (02) : 131 - 143