C-arm CT for histomorphometric evaluation of lumbar spine trabecular microarchitecture: a study on anorexia nervosa patients

被引:1
|
作者
Phan, C. M. [1 ]
Khalilzadeh, O. [1 ]
Dinkel, J. [1 ]
Wang, I. S. [1 ]
Bredella, M. A. [1 ]
Misra, M. [2 ,3 ]
Miller, K. K. [2 ]
Klibanski, A. [2 ]
Gupta, R. [1 ]
机构
[1] Harvard Univ, Sch Med, Dept Radiol, Massachusetts Gen Hosp, Boston, MA 02115 USA
[2] Harvard Univ, Sch Med, Massachusetts Gen Hosp, Neuroendocrine Unit, Boston, MA USA
[3] Harvard Univ, Sch Med, Massachusetts Gen Hosp Children, Pediat Endocrine Unit, Boston, MA USA
来源
BRITISH JOURNAL OF RADIOLOGY | 2013年 / 86卷 / 1027期
关键词
COMPUTED-TOMOGRAPHY; ADOLESCENT GIRLS; DISTAL RADIUS; WOMEN; OSTEOPOROSIS; DENSITY; RISK;
D O I
10.1259/bjr.20120451
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Bone histomorphometry measurements require high spatial resolution that may not be feasible using multidetector CT (MDCT). This study evaluated the trabecular microarchitecture of lumbar spine using MDCT and C-arm CT in a series of young adult patients with anorexia nervosa (AN). 11 young females with AN underwent MDCT (anisotropic resolution with a slice thickness of similar to 626 mu m) and C-arm CT (isotropic resolution of 200 pm). Standard histomorphometric parameters the of L1 vertebral body, namely the apparent trabecular bone volume fraction (BV/TV), trabecular thickness (TbTh), trabecular number (TbN) and trabecular separation (TbSp), were analysed using MicroView software (GE Healthcare, Piscataway, NJ). Bone mineral density (BMD) was measured using dual-energy X-ray absorptiometry. Trabecular parameters derived from MDCT and C-arm CT were compared, and their association with F3MD parameters was evaluated. Histomorphonnetric parameters derived from C-arm CT, namely TbTh, TbN and TbSp, were significantly different from the corresponding MDCT parameters. There were no significant correlations between C-arm CT-derived parameters and the corresponding MDCT-derived parameters. C-arm CT-derived parameters were significantly (p<0.001) correlated with anteroposterior L1 spine BMD and Z-scores: TbTh (r=0.723, r=0.744, respectively), TbN.(r=-0.720, r=-0.712, respectively) and TbSp (r=0.656, r=0.648, respectively). BV/TV, derived from C-arm CT, was significantly associated with body mass index (r=0.636) and ideal body weight (r=0.730) (p<0.05). These associations were not present in MDCT-derived parameters. This study suggests that the spatial resolution offered by C-arm CT more accurately captures the histomorphometric parameters of trabecular morphology than MDCT in patients with AN.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Assessment of Lumbar Spine Instability Using C-Arm Fluoroscopy
    Temes, Bill
    Karas, Steve
    Manwill, James
    [J]. JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2016, 46 (09): : 810 - 810
  • [2] Trabecular Bone Score as a Reliable Measure of Lumbar Spine Bone Microarchitecture in Acromegalic Patients
    Nazzari, Elena
    Casabella, Andrea
    Paolino, Sabrina
    Campana, Claudia
    Corica, Giuliana
    Nista, Federica
    Milioto, Angelo
    Tagliafico, Alberto
    Albertelli, Manuela
    Boschetti, Mara
    Bagnasco, Marcello
    Cutolo, Maurizio
    Ferone, Diego
    Gatto, Federico
    [J]. JOURNAL OF CLINICAL MEDICINE, 2022, 11 (21)
  • [3] Performance evaluation of a C-Arm CT perfusion phantom
    Boese, Axel
    Gugel, Sebastian
    Serowy, Steffen
    Purmann, Jonas
    Rose, Georg
    Beuing, Oliver
    Skalej, Martin
    Kyriakou, Yiannis
    Yu Deuerling-Zheng
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2013, 8 (05) : 799 - 807
  • [4] Performance evaluation of a C-Arm CT perfusion phantom
    Axel Boese
    Sebastian Gugel
    Steffen Serowy
    Jonas Purmann
    Georg Rose
    Oliver Beuing
    Martin Skalej
    Yiannis Kyriakou
    Yu Deuerling-Zheng
    [J]. International Journal of Computer Assisted Radiology and Surgery, 2013, 8 : 799 - 807
  • [5] CT AND MR EVALUATION OF THE BRAIN IN PATIENTS WITH ANOREXIA-NERVOSA
    KORNREICH, L
    SHAPIRA, A
    HOREV, G
    DANZIGER, Y
    TYANO, S
    MIMOUNI, M
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 1991, 12 (06) : 1213 - 1216
  • [6] Trabecular structure analysis using C-arm CT: comparison with MDCT and flat-panel volume CT
    Catherine M. Phan
    Eric A. Macklin
    Miriam A. Bredella
    Monica Dadrich
    Paul Flechsig
    Albert J. Yoo
    Joshua A. Hirsch
    Rajiv Gupta
    [J]. Skeletal Radiology, 2011, 40 : 1065 - 1072
  • [7] LUMBAR SPINE MICROARCHITECTURE IMPAIRMENT EVALUATION IN CHRONIC KIDNEY DISEASE: A TBS STUDY
    Leib, Edward
    Stoll, Delphine
    Winzenrieth, Renaud
    Hans, Didier
    [J]. OSTEOPOROSIS INTERNATIONAL, 2013, 24 : S319 - S319
  • [8] Trabecular structure analysis using C-arm CT: comparison with MDCT and flat-panel volume CT
    Phan, Catherine M.
    Macklin, Eric A.
    Bredella, Miriam A.
    Dadrich, Monica
    Flechsig, Paul
    Yoo, Albert J.
    Hirsch, Joshua A.
    Gupta, Rajiv
    [J]. SKELETAL RADIOLOGY, 2011, 40 (08) : 1065 - 1072
  • [9] Appropriate insertion point for percutaneous pedicle screw placement in the lumbar spine using c-arm fluoroscopy: a cadaveric study
    Wei-Xing Xu
    Wei-Guo Ding
    Bin Xu
    Tian-Hong Hu
    Hong-Feng Sheng
    Jia-Fu Zhu
    Xiao-Long Zhu
    [J]. BMC Musculoskeletal Disorders, 21
  • [10] C-arm Fluoroscopic Cone Beam CT for Guidance of Minimally Invasive Spine Interventions
    Powell, Michael F.
    DiNobile, Diane
    Reddy, Arra S.
    [J]. PAIN PHYSICIAN, 2010, 13 (01) : 51 - 59