Performance evaluation of a C-Arm CT perfusion phantom

被引:0
|
作者
Axel Boese
Sebastian Gugel
Steffen Serowy
Jonas Purmann
Georg Rose
Oliver Beuing
Martin Skalej
Yiannis Kyriakou
Yu Deuerling-Zheng
机构
[1] Otto-von-Guericke University,Chair for Healthcare Telematics and Medical Engineering
[2] Otto-von-Guericke University,Department of Neuroradiology
[3] Siemens AG,undefined
[4] Healthcare Sector,undefined
关键词
Phantom; Perfusion; CT; C-Arm CT; Imaging ; Blood flow;
D O I
暂无
中图分类号
学科分类号
摘要
Purpose Brain perfusion measurement in stroke patients provides important information on the infarct area and state of involved tissue. Interventional C-Arm angiography systems can provide perfusion measurements. A CT perfusion phantom was developed for C-Arm perfusion imaging to test and evaluate this method and to aid in the design and validation of scan protocols.
引用
收藏
页码:799 / 807
页数:8
相关论文
共 50 条
  • [1] Performance evaluation of a C-Arm CT perfusion phantom
    Boese, Axel
    Gugel, Sebastian
    Serowy, Steffen
    Purmann, Jonas
    Rose, Georg
    Beuing, Oliver
    Skalej, Martin
    Kyriakou, Yiannis
    Yu Deuerling-Zheng
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2013, 8 (05) : 799 - 807
  • [2] A Realistic Digital Phantom for Perfusion C-arm CT based on MRI Data
    Aichert, Andre
    Manhart, Michael T.
    Navalpakkam, Bharath K.
    Grimm, Robert
    Hutter, Jana
    Maier, Andreas
    Hornegger, Joachim
    Doerfler, Arnd
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [3] C-arm CT Perfusion Imaging in the Interventional Suite
    Fieselmann, Andreas
    Manhart, Michael
    CURRENT MEDICAL IMAGING, 2013, 9 (02) : 96 - 101
  • [4] In vitro evaluation of the imaging accuracy of C-arm conebeam CT in cerebral perfusion imaging
    Ganguly, A.
    Fieselmann, A.
    Boese, J.
    Rohkohl, C.
    Hornegger, J.
    Fahrig, R.
    MEDICAL PHYSICS, 2012, 39 (11) : 6652 - 6659
  • [5] Myocardial perfusion assessment using C-arm CT angiography
    Rieber, J.
    Sinha, A.
    Schmidt, M.
    Lauritsch, G.
    Koenig, A.
    Klauss, V.
    Rittger, H.
    EUROPEAN HEART JOURNAL, 2010, 31 : 578 - 578
  • [6] Detection of pulmonary nodules by C-arm CT using a phantom lung: comparison with CT
    Higashihara, Hiroki
    Osuga, Keigo
    Azuma, Takeo
    Nakazawa, Tetsuro
    Yanagawa, Masahiro
    Kikuyama, Ayano
    Maeda, Noboru
    Tomiyama, Noriyuki
    ACTA RADIOLOGICA, 2011, 52 (09) : 964 - 968
  • [7] Radiation dose evaluation in tomosynthesis and C-arm cone-beam CT examinations with an anthropomorphic phantom
    Koyama, Shuji
    Aoyama, Takahiko
    Oda, Nobuhiro
    Yamauchi-Kawaura, Chiyo
    MEDICAL PHYSICS, 2010, 37 (08) : 4298 - 4306
  • [8] Performance evaluation for new-technology CT systems: Cone beam C-arm CT
    Fahrig, R.
    MEDICAL PHYSICS, 2007, 34 (06) : 2510 - 2510
  • [9] Technical Feasibility of CT Perfusion using a C-Arm CBCT System
    Xu, Min
    Tang, Jie
    Royalty, Kevin
    Chen, Guang-Hong
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [10] A Filter Model to Analyze Reconstruction Artifacts in Perfusion C-arm CT
    Fieselmann, Andreas
    Dennerlein, Frank
    Deuerling-Zheng, Yu
    Boese, Jan
    Fahrig, Rebecca
    Hornegger, Joachim
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2239 - 2242