Non-invasive measurement of intra-abdominal pressure: a preliminary study

被引:18
|
作者
van Ramshorst, G. H. [1 ]
Lange, J. F. [1 ]
Goossens, R. H. M.
Agudelo, N. L.
Kleinrensink, G. J.
Verwaal, M.
Flipsen, S. F. J.
Hop, W. C. J.
Wauben, L. S. G. L.
Jeekel, J. [1 ]
机构
[1] Erasmus Univ, Med Ctr, Dept Surg, NL-3000 CA Rotterdam, Netherlands
关键词
mechanical device; medical technology; intra-abdominal pressure; intra-abdominal hypertension; abdominal tension; abdominal compartment syndrome;
D O I
10.1088/0967-3334/29/8/N01
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The importance of measuring intra-abdominal pressure (IAP) has increased since the negative effects of sustained increased IAP, also known as intra-abdominal hypertension (IAH), have become known. The relation between IAP and abdominal wall tension has been included in several reports. We have developed a device to measure abdominal wall tension by measuring force and distance. This device enables us to investigate the correlation between the abdominal wall tension and IAP. The abdomens of two corpses (one female, one male) were insufflated with air. IAP was increased and measured at intervals by means of a laparoscopic set-up. Abdominal tension was measured at seven points on the abdominal wall at each interval. Pearson's correlation coefficients were used to determine the relationship between IAP and tension for each point measured. ANOVA was used to assess relations between measured tensions versus applied pressure, locations and subjects. In both corpses, all points showed significant (p < 0.001) correlations between IAP and abdominal wall tension. The points along the mid transverse plane appear to be more similar compared to more cranial and caudal points. We have assessed the feasibility of a device that non-invasively can track changes in IAP. Measurements performed with the device are preliminary results, and further investigation is needed.
引用
收藏
页码:N41 / N47
页数:7
相关论文
共 50 条
  • [31] Impact of two extubation techniques on the intra-abdominal pressure: a preliminary study
    R. Nemecek
    E. Nemecek
    C. Glaser
    T. Wallner
    F. Ratzinger
    C. Hollinsky
    Hernia, 2015, 19 : 307 - 311
  • [32] Assessment of Intra-Abdominal Pressure by Measurement of Abdominal Wall Tension
    Havens, Joaquim M.
    Soybel, David I.
    JOURNAL OF SURGICAL RESEARCH, 2011, 166 (01) : 70 - 72
  • [33] Non-invasive treatment of intra-abdominal hypertension: The search for the Holy Grail continues...
    Malbrain, M. L. N. G.
    De laet, I.
    De Waele, J.
    ACTA CLINICA BELGICA, 2008, 63 (02) : 63 - 66
  • [34] The role of non-invasive imaging techniques in detecting intra-abdominal adhesions: a systematic review
    Jonas Gerner-Rasmussen
    Anders Meller Donatsky
    Flemming Bjerrum
    Langenbeck's Archives of Surgery, 2019, 404 : 653 - 661
  • [35] The role of non-invasive imaging techniques in detecting intra-abdominal adhesions: a systematic review
    Gerner-Rasmussen, Jonas
    Donatsky, Anders Meller
    Bjerrum, Flemming
    LANGENBECKS ARCHIVES OF SURGERY, 2019, 404 (06) : 653 - 661
  • [36] INTRA-ABDOMINAL PRESSURE
    LIGHT, HG
    ROUTLEDGE, JA
    ARCHIVES OF SURGERY, 1965, 90 (01) : 115 - +
  • [37] INTRA-ABDOMINAL PRESSURE
    ASPDEN, R
    CLINICAL BIOMECHANICS, 1988, 3 (01) : 48 - 48
  • [38] Intra-abdominal pressure, intra-abdominal hypertension, and pregnancy: a review
    Rosaleen Chun
    Andrew W Kirkpatrick
    Annals of Intensive Care, 2
  • [39] Intra-abdominal pressure, intra-abdominal hypertension, and pregnancy: a review
    Chun, Rosaleen
    Kirkpatrick, Andrew W.
    ANNALS OF INTENSIVE CARE, 2012, 2
  • [40] New technique of direct intra-abdominal pressure measurement
    Risin, Elena
    Kessel, Boris
    Lieberman, Noah
    Schmilovich, Michael
    Ashkenazi, Itamar
    Alfici, Ricardo
    ASIAN JOURNAL OF SURGERY, 2006, 29 (04) : 247 - 250