A field study of indoor air quality and occupant perception in experimental laboratories and workshops

被引:10
|
作者
Kwong, Qi Jie [1 ,2 ]
Abdullah, Jamalunlaili [1 ]
Tan, Sheng Chuan [2 ]
Thio, Tzer Hwai Gilbert [3 ]
Yeaw, Win Shyang [2 ]
机构
[1] Univ Teknol MARA, Fac Architecture Planning & Surveying, Shah Alam, Malaysia
[2] Inti Int Univ, Fac Engn & Quant Surveying, Nilai, Malaysia
[3] SEGi Univ, Fac Engn & Built Environm, CCIS, Petaling Jaya, Malaysia
关键词
Indoor air quality; Workshops; Laboratories; Indoor air pollutants; Sick building syndrome; SELANGOR; CHILDREN; ASTHMA;
D O I
10.1108/MEQ-04-2018-0074
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Purpose Maintaining good indoor air quality (IAQ) in the built environment is essential to assure health, safety and productivity of occupants. The purpose of this paper is to report on the preliminary IAQ assessment of selected air-conditioned laboratories and naturally ventilated workshops in a tropical education institution. Design/methodology/approach The concentration levels of five major indoor air pollutants (IAPs) - carbon dioxide, carbon monoxide, respirable particulates, formaldehyde (HCHO) and total volatile organic compounds (TVOC) in each sampling area were measured using calibrated air sampling sensors and the tracer-gas analysis was used to determine the ventilation effectiveness. A questionnaire survey was carried out concurrently to study the prevalence of sick building syndrome (SBS) among users of laboratories and workshops and the data collected were statistically analysed using chi(2) test. Findings The air pollutant levels were found to be below the threshold limit values set in the local code of practice on IAQ, except for two of the air-conditioned laboratories. This is possibly due to insufficient ventilation, smaller floor area per occupant ratio, long-term exposure to chemical substances, and improper disposal of the used chemical substances. The total particulate levels were higher in naturally ventilated workshops because such spaces were assigned for mechanical works which involved grinding, welding and fabrication. Besides, it was identified that most of the air contaminant levels were not normally distributed (p<0.05) within the sampling areas and SBS like dry eyes, watery eyes, tiredness and dry throat were reported in both laboratories and workshops. The outcomes of this work suggest that an increase of ventilation rate was necessary to reduce the concentration of the IAPs in air-conditioned laboratories and improved housekeeping would help mitigate the prevalence of SBS symptoms. Research limitations/implications This research was carried out in selected laboratories and workshops in a Malaysian educational institution and only five major IAPs stipulated in the Department of Occupational Safety and Health (DOSH) code of practice were measured. Practical implications - The results of this study will enable facility engineers and managers to understand the IAPs concentration levels and potential SBS problems in academic laboratories and workshops. The recommended strategies can be considered to improve IAQ conditions in such spaces. Originality/value Most of the previously conducted IAQ studies focused only on commonly occupied building spaces such as offices, classrooms and houses. Information of the quality of air and SBS conditions in experimental facilities in developing nations that is available is currently very limited. This case study provides detailed information on IAQ in laboratories and workshops in Malaysia with focuses on the concentration levels of particular harmful gases, the prevalence of SBS among users of these facilities and the appropriate mitigation strategies. The results presented are of value to both academic and industry communities.
引用
收藏
页码:467 / 482
页数:16
相关论文
共 50 条
  • [1] Indoor air quality in chemistry laboratories
    Hays, SM
    [J]. AMERICAN LABORATORY, 2000, 32 (17) : 34 - +
  • [2] Indoor air quality in university laboratories
    Spickett, J
    van den Broeck, V
    Rumchev, K
    [J]. EPIDEMIOLOGY, 2003, 14 (05) : S117 - S117
  • [3] Occupant perception of indoor air and comfort in four hospitality environments
    Moschandreas, DJ
    Chu, P
    [J]. AIHAJ, 2002, 63 (01): : 47 - 54
  • [4] Persistent allergic rhinitis and indoor air quality perception - an experimental approach
    Graudenz, G. S.
    Latorre, M. R. D. O.
    Tribess, A.
    Oliveira, C. H.
    Kalil, J.
    [J]. INDOOR AIR, 2006, 16 (04) : 313 - 319
  • [5] Field measurement of the impact of natural ventilation and portable air cleaners on indoor air quality in three occupant states
    Yin H.
    Li Z.
    Zhai X.
    Ning Y.
    Gao L.
    Cui H.
    Ma Z.
    Li A.
    [J]. Energy and Built Environment, 2023, 4 (05): : 601 - 613
  • [6] Indoor Air Quality Monitoring Improving Air Quality Perception
    Herberger, Simone
    Ulmer, Heiko
    [J]. CLEAN-SOIL AIR WATER, 2012, 40 (06) : 578 - 585
  • [7] Attempt to improve indoor air quality in computer laboratories
    Telejko, Marek
    [J]. MODERN BUILDING MATERIALS, STRUCTURES AND TECHNIQUES, 2017, 172 : 1154 - 1160
  • [8] Gender differences in office occupant perception of indoor environmental quality (IEQ)
    Kim, Jungsoo
    de Dear, Richard
    Candido, Christhina
    Zhang, Hui
    Arens, Edward
    [J]. BUILDING AND ENVIRONMENT, 2013, 70 : 245 - 256
  • [9] Numerical and Experimental Study on Indoor Air Distribution and Quality
    Gao, Zhen
    Jiang, Yun
    Ouyang, Kuangzhong
    Hu, Haowei
    Zhang, Siwei
    Ma, Jinwei
    [J]. PROCEEDINGS OF THE 2017 6TH INTERNATIONAL CONFERENCE ON ENERGY, ENVIRONMENT AND SUSTAINABLE DEVELOPMENT (ICEESD 2017), 2017, 129 : 770 - 775
  • [10] Effects of mechanical ventilation on indoor air quality and occupant health status in energy-efficient homes: A longitudinal field study
    Lim, Ah-Young
    Yoon, Miryoung
    Kim, Eun-Hye
    Kim, Hyun-Ah
    Lee, Myoung Ju
    Cheong, Hae-Kwan
    [J]. SCIENCE OF THE TOTAL ENVIRONMENT, 2021, 785