Numerical and Experimental Study on Indoor Air Distribution and Quality

被引:0
|
作者
Gao, Zhen [1 ,3 ]
Jiang, Yun [2 ,3 ]
Ouyang, Kuangzhong [2 ,3 ]
Hu, Haowei [2 ,3 ]
Zhang, Siwei [1 ,3 ]
Ma, Jinwei [2 ,3 ]
机构
[1] Chinese Hefei Railway Constrct Real Estate Grp CO, Hefei 230041, Anhui, Peoples R China
[2] Anhui Jianzhu Univ, Coll Environm & Energy Engn, Hefei 230601, Anhui, Peoples R China
[3] Anhui Jianzhu Univ, Anhui Adv Technol Res Inst Green Bldg, Hefei 230601, Anhui, Peoples R China
关键词
fresh air system; air distribution; optimization study; simulation; FORMALDEHYDE; TVOC;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
To optimize and control the indoor air distribution and quality, theindoor temperature and humidity were measured based on indoor fresh air system. The one measurementwas indoor temperature and humidity in both cases of return air and without return air in winter respectively. The other was indoor temperature and humidity in both cases of return air and without return air in summer respectively. In additional, the test room environment was simulated using the finite element analysis software of ANSYS. Through setting a variety of air organization operating modes, the best solution of indoor air flow could be obtained.
引用
收藏
页码:770 / 775
页数:6
相关论文
共 50 条
  • [1] Numerical Simulation of Air Distribution's Impact on Indoor Air Quality
    Zhang, Min
    Zhao, Bin
    [J]. 3RD INTERNATIONAL CONFERENCE ON APPLIED ENGINEERING, 2016, 51 : 1 - 6
  • [2] Numerical and Experimental Study on the Indoor Climate in a Classroom with Mixing and Displacement Air Distribution Methods
    Zhao, Weixin
    Mustakallio, Panu
    Lestinen, Sami
    Kilpelainen, Simo
    Jokisalo, Juha
    Kosonen, Risto
    [J]. BUILDINGS, 2022, 12 (09)
  • [3] Numerical study on indoor air distribution for VAV system
    Zhao, B
    Li, Y
    Li, XT
    Yan, QS
    [J]. INTERNATIONAL SYMPOSIUM ON AIR CONDITIONING IN HIGH RISE BUILDINGS '2000, PROCEEDINGS, 2000, 2000 (03): : 371 - 375
  • [4] Numerical Study on Indoor Air Quality of Commercial Kitchen in China
    Hou, Xiaotan
    Li, Angui
    Wang, Zhihua
    Zhao, Yujiao
    [J]. SUSTAINABLE DEVELOPMENT OF URBAN ENVIRONMENT AND BUILDING MATERIAL, PTS 1-4, 2012, 374-377 : 1100 - 1105
  • [5] Comparison of numerical simulation and experimental study on indoor air quality of air-conditioned office building in desert climate
    Wahhad, A. M.
    Adam, N. M.
    Sapuan, S. M.
    [J]. INTERNATIONAL JOURNAL OF AUTOMOTIVE AND MECHANICAL ENGINEERING, 2015, 12 : 3109 - 3124
  • [6] Experimental and numerical investigations of indoor air movement distribution with an office ceiling fan
    Chen, Wenhua
    Liu, Shichao
    Gao, Yunfei
    Zhang, Hui
    Arens, Edward
    Zhao, Lei
    Liu, Junjie
    [J]. BUILDING AND ENVIRONMENT, 2018, 130 : 14 - 26
  • [7] A NUMERICAL AND EXPERIMENTAL STUDY OF THE EFFECT OF USING PERSONAL VENTILATION SYSTEMS ON INDOOR AIR QUALITY IN OFFICE ROOMS
    Saheb, Hussien Aziz
    Mahdi, Ala'a Abbas
    Al-amir, Qusay Rasheed
    [J]. FRONTIERS IN HEAT AND MASS TRANSFER, 2021, 16
  • [8] Experimental Prototype and Measurement Driven Study of Indoor Air Quality
    Alkaabi, Shaikha
    Suhail, Fatema S.
    Almansoori, Haleema
    Alhammadi, Asma
    Kulkarni, Shriya
    Pradeep, Bivin
    Kulkarni, Parag
    [J]. 2023 IEEE INTERNATIONAL WORKSHOP ON METROLOGY FOR LIVING ENVIRONMENT, METROLIVENV, 2023, : 157 - 161
  • [9] NATURAL VENTILATION POTENTIAL IMPROVING INDOOR AIR QUALITY: EXPERIMENTAL AND NUMERICAL STUDIES
    El Mankibi, M.
    Stathopoulos, N.
    Michel, P.
    [J]. 7TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, PROCEEDINGS OF ISHVAC 2011, VOLS I-IV, 2011, : 1040 - 1045
  • [10] An experimental study of the indoor air quality in areas of different use
    Assimakopoulos, V. D.
    Saraga, D.
    Helmis, C. G.
    Stathopoulou, O. I.
    Halios, C. H.
    [J]. GLOBAL NEST JOURNAL, 2008, 10 (02): : 192 - 200