COMPREHENSIVE LOW-FLOW ANALYSIS OF THE VIPAVA RIVER

被引:2
|
作者
Jelovcan, Mateja [1 ]
Sraj, Mojca [2 ]
机构
[1] Univ Ljubljana, Fac Nat Sci & Engn, Ljubljana, Slovenia
[2] Univ Ljubljana, Fac Civil & Geodet Engn, Ljubljana, Slovenia
关键词
low-flow analysis; lfstat package; Vipava River; Vipava Valley; Slovenia; EVENTS;
D O I
10.3986/AGS.9399
中图分类号
P9 [自然地理学];
学科分类号
0705 ; 070501 ;
摘要
The article presents the results of the analysis of low flows at 5 gauging stations on the Vipava River, which has a Dinaric pluvial-nival regime (catchment area of 590 km(2)). The low-flow statistics show that the gauging station Vipava stands out with the lowest values. Baseflow index (BFI) values are comparable among the considered stations and are around 0.40. Relatively low BFI values indicate low soil permeability. A high similarity between the mean annual minimum 7-day flow (MAM7) and the 95th percentile exceedance discharge (Q95) at all gauging stations indicates a temperate climate. The highest flows values occur in spring and autumn, and the lowest in summer. In wet years there are relatively large fluctuations in flow, while in dry years the flow consists mainly of baseflow. This is also confirmed with the flow duration curves analysis. The seasonality analysis shows a predominant summer regime with low flows.
引用
收藏
页码:37 / 53
页数:17
相关论文
共 50 条
  • [41] Low-flow anaesthesia with xenon
    Baum, J
    ANASTHESIOLOGIE INTENSIVMEDIZIN NOTFALLMEDIZIN SCHMERZTHERAPIE, 1997, 32 (01): : 51 - 55
  • [42] Selecting low-flow pumps
    Tritech Technologies, Bloomingdale, United States
    Chem Eng (New York), 2 (78-82):
  • [43] A LOW-FLOW HAZARD INDICATOR
    Kepinska-Kasprzak, Malgorzata
    II KRAJOWY KONGRES HYDROLOGICZNY - HYDROLOGIA W INZYNIERII I GOSPODARCE WODNEJ, TOM I, 2014, 20 : 163 - 172
  • [44] LOW-FLOW METERING VALVE
    GRUNWALD, A
    INSTRUMENTATION TECHNOLOGY, 1967, 14 (02): : 68 - &
  • [45] The occasional low-flow priapism
    Baker, Andrew
    Patey, Christopher
    Al-Obaidi, Hasan
    CANADIAN JOURNAL OF RURAL MEDICINE, 2020, 25 (04) : 150 - 153
  • [46] LOW-FLOW RADIATORS: A PRIMER
    Anon
    1600, (93):
  • [47] LOW-FLOW ANESTHESIA REVISITED
    BROCK, N
    CANADIAN VETERINARY JOURNAL-REVUE VETERINAIRE CANADIENNE, 1995, 36 (06): : 366 - 367
  • [48] IMPROVING LOW-FLOW DISTILLATIONS
    KILLAT, G
    PERRY, D
    CHEMICAL ENGINEERING, 1992, 99 (10) : 185 - 186
  • [49] A PLEA FOR LOW-FLOW ANESTHESIA
    BAUM, J
    ANAESTHESIST, 1992, 41 (08): : 503 - 504
  • [50] The low-flow or high-flow oxygen delivery system and a low-flow or high-flow nonrebreather mask
    Agarwal, Ritesh
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2006, 174 (09) : 1055 - 1055