AC Losses of a Grid-Connected Superconducting Wind Turbine Generator

被引:28
|
作者
Queval, Loic [1 ]
Ohsaki, Hiroyuki [1 ]
机构
[1] Univ Tokyo, Grad Sch Frontier Sci, Dept Adv Energy, Tokyo 1138654, Japan
关键词
AC losses; numerical analysis; superconducting wind turbine generator; CURRENTS; MODEL;
D O I
10.1109/TASC.2013.2251252
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present a numerical method to estimate the steady-state AC losses of a superconducting wind turbine generator connected to the grid through its AC/DC/AC converter. We use a multiscale simulation with unidirectional couplings between a lumped-parameter wind energy conversion system model, a finite element machine model, and a finite element HTS tape model. The estimation include effects linked to the generator space harmonics, the exciter control, and the AC/DC/AC converter PWM and control. As the superconducting coil is made of several thousand of HTS tapes, we evaluate AC losses for a fraction of them and we interpolate the results to the others. The steady-state AC losses of a 10 MW class generator are estimated to be under 60 W.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Small-Signal Stability Analysis of a Grid-Connected Wind-Turbine Generator Based on Dynamic-Slip Induction Generator
    Wang, Li
    Chang, Che-Hao
    Tseng, Ching-Chuan
    Prokhorov, Anton, V
    Mokhlis, Hazlie
    Huat, Chua Kein
    Tripathy, Manoj
    2021 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING (IAS), 2021,
  • [42] Power output fluctuation analysis of grid-connected wind turbine-generator system with limiting maximum power output
    Wakui, Tetsuya
    Yokoyama, Ryohei
    ASME 2011 5th International Conference on Energy Sustainability, ES 2011, 2011, (PARTS A, B, AND C): : 2193 - 2201
  • [43] Effect of Static VAR Compensator positioning on a Grid-connected wind turbine-driven Squirrel Cage Induction Generator
    Oyekanmi, Waheed A.
    Radman, Ghadir
    Babalola, Adeniyi A.
    Uzoechi, Lazarus O.
    2013 IEEE INTERNATIONAL CONFERENCE ON EMERGING & SUSTAINABLE TECHNOLOGIES FOR POWER & ICT IN A DEVELOPING SOCIETY (NIGERCON 2013), 2013, : 247 - 252
  • [44] POWER OUTPUT FLUCTUATION ANALYSIS OF GRID-CONNECTED WIND TURBINE-GENERATOR SYSTEM WITH LIMITING MAXIMUM POWER OUTPUT
    Wakui, Tetsuya
    Yokoyama, Ryohei
    PROCEEDINGS OF THE ASME 5TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY 2011, PTS A-C, 2012, : 2191 - 2199
  • [45] Evaluation and Mitigation of AC Losses in a Fully Superconducting Machine for Wind Turbine Applications
    Balachandran, Thanatheepan
    Lee, Dongsu
    Salk, Noah
    Xiao, Jianqiao
    Haran, Kiruba S.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2020, 30 (04)
  • [46] Lyapunov stability of grid-connected wind turbines with permanent magnet synchronous generator
    Nguyen, Phuong T. H.
    Studli, Sonja
    Braslavsky, Julio H.
    Middleton, Richard H.
    EUROPEAN JOURNAL OF CONTROL, 2022, 65
  • [47] Grid-Connected Inverter Based on Virtual Synchronous Generator Emulation in Wind Application
    Ji, Changan
    Li, Wei
    Luo, Yaqiao
    Hong, Wei
    Feng, Lin
    Zhu, Minglin
    Hang, Lijun
    Li, Guojie
    3RD ASIAN PACIFIC CONFERENCE ON ENERGY, ENVIRONMENT AND SUSTAINABLE DEVELOPMENT (APEESD 2017), 2017, : 16 - 20
  • [48] A 20kW grid-connected wind turbine for rural electricity users
    Jenkins, G
    Bennett, P
    Thornton, A
    WIND ENERGY CONVERSION 1997, 1997, : 87 - 96
  • [49] The Design of Inductance in AC Side of grid-connected Inverter in Wind Power Generation
    Yang Yong
    Ruan Yi
    Shen Huan-qing
    Tan Yan-yan
    Yang Ying
    ICEMS 2008: PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1- 8, 2008, : 2464 - 2469
  • [50] Analysis on the influence of an SVG on the stability of AC grid-connected offshore wind farms
    Chen H.
    Xiong X.
    Yu H.
    Li Y.
    Han Y.
    Sun H.
    Duan Y.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2022, 50 (19): : 119 - 129