INVESTIGATION OF DIAMETER EFFECT ON CRITICAL FLOW

被引:0
|
作者
Zhao Minfu [1 ]
Lv Yufeng [1 ]
Zhang Dongxu [1 ]
Chen Yuzhou [1 ]
Bi Keming [1 ]
机构
[1] China Inst Atom Energy, Beijing, Peoples R China
关键词
Critical flow; diameter effect; pressure change velocity; transient effect;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Discrepancy has long existed about nozzle diameter effect on critical flow rate in two-phase critical flow analysis. The issue is of great importance because it involves whether the scaling test can accurately simulate the actual process during loss of coolant accident. A series of transient critical flow experiments has been performed in China Institute of Atomic Energy (CIAE), which aims to study the nozzle diameter effect. The diameter of adopted test nozzle is 5mm, 10mm and 15mm, respectively. The experiment result shows that the discharge mass flow rate decreases as nozzle diameter increases. This is contradictory with the results obtained from steady state critical flow experiment. Comprehensive analysis shows that the diameter effect observed in transient critical flow experiment is transient effect caused by system pressure change, and the mechanism is the dynamic unbalance in the transient period. It is presumed that for the same test section with a certain diameter, if the pressure change velocity is different, the measured critical flow rate will be different. The conclusion is validated in the pressurization and depressurization blowdown test. 14 is arrived that nozzle diameter has no direct effect on critical flow rate, and thus the discrepancy on diameter effect is clarified.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] Development of the entropy generation investigation for slug flow in a large diameter pipe
    Mohammadi, Samira
    Jahangiri, Ali
    Emamzadeh, Mohammad
    Majidi, Sahand
    Dezfouli, Amir Hossein Mardan
    Chamkha, Ali J.
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2023, 144
  • [42] Investigation of bubble departure diameter in horizontal and vertical subcooled flow boiling
    Du, Jingyu
    Zhao, Chenru
    Bo, Hanliang
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 127 : 796 - 805
  • [43] Numerical and Experimental Investigation on Flow Dynamics in a Pipe With an Abrupt Change in Diameter
    Annus, Ivar
    Kartushinsky, Alexander
    Vassiljev, Anatoli
    Kaur, Katrin
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2019, 141 (10):
  • [44] Critical combustion diameter
    Romanov, O. Ya.
    COMBUSTION EXPLOSION AND SHOCK WAVES, 2007, 43 (01) : 25 - 33
  • [45] NUMERICAL INVESTIGATION OF CRITICAL HEAT FLUX UNDER THE EFFECT OF DIFFERENT OPERATING CONDITIONS IN FLOW BOILING
    Angeneh, Saeid R.
    Aktas, Murat K.
    PROCEEDINGS OF CONV-22: INT SYMP ON CONVECTIVE HEAT AND MASS TRANSFER, 2022, 2022,
  • [46] Critical combustion diameter
    O. Ya. Romanov
    Combustion, Explosion, and Shock Waves, 2007, 43 : 25 - 33
  • [47] DIAMETER CRITICAL GRAPHS
    CACCETTA, L
    HAGGKVIST, R
    DISCRETE MATHEMATICS, 1979, 28 (03) : 223 - 229
  • [48] Diameter critical graphs
    Loh, Po-Shen
    Ma, Jie
    JOURNAL OF COMBINATORIAL THEORY SERIES B, 2016, 117 : 34 - 58
  • [49] Investigation of the Effect of Cardiopulmonary Bypass on Optic Nerve Sheath Diameter
    Karaca, Umran
    Ozyaprak, Buket
    Onur, Tugba
    Onur, Anil
    Balkaya, Ayse Neslihan
    Erkan, Gonul
    Engin, Mesut
    HEART SURGERY FORUM, 2024, 27 (07): : E718 - E724
  • [50] Investigation on the Critical Flow Through a Rectangular Narrow Slit
    Huang B.
    Zhang B.
    Sun Y.
    Gong S.
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2020, 54 (05): : 26 - 31