INVESTIGATION OF DIAMETER EFFECT ON CRITICAL FLOW

被引:0
|
作者
Zhao Minfu [1 ]
Lv Yufeng [1 ]
Zhang Dongxu [1 ]
Chen Yuzhou [1 ]
Bi Keming [1 ]
机构
[1] China Inst Atom Energy, Beijing, Peoples R China
关键词
Critical flow; diameter effect; pressure change velocity; transient effect;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Discrepancy has long existed about nozzle diameter effect on critical flow rate in two-phase critical flow analysis. The issue is of great importance because it involves whether the scaling test can accurately simulate the actual process during loss of coolant accident. A series of transient critical flow experiments has been performed in China Institute of Atomic Energy (CIAE), which aims to study the nozzle diameter effect. The diameter of adopted test nozzle is 5mm, 10mm and 15mm, respectively. The experiment result shows that the discharge mass flow rate decreases as nozzle diameter increases. This is contradictory with the results obtained from steady state critical flow experiment. Comprehensive analysis shows that the diameter effect observed in transient critical flow experiment is transient effect caused by system pressure change, and the mechanism is the dynamic unbalance in the transient period. It is presumed that for the same test section with a certain diameter, if the pressure change velocity is different, the measured critical flow rate will be different. The conclusion is validated in the pressurization and depressurization blowdown test. 14 is arrived that nozzle diameter has no direct effect on critical flow rate, and thus the discrepancy on diameter effect is clarified.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Theoretical investigation of the diameter effect on flooding in countercurrent flow
    Jayanti, S
    Tokarz, A
    Hewitt, GF
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1996, 22 (02) : 307 - 324
  • [2] The effect of the tube diameter on the critical heat flux in subcooled flow boiling
    Celata, GP
    Cumo, M
    Mariani, A
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1996, 39 (08) : 1755 - 1757
  • [3] EFFECT OF DIAMETER ON CRITICAL WEISSENBERG NUMBERS FOR POLYACRYLAMIDE SOLUTIONS IN TURBULENT PIPE-FLOW
    KWACK, EY
    HARTNETT, JP
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1982, 25 (06) : 797 - 805
  • [4] The Effect of Linear Change of Tube Diameter on Subcooled Flow Boiling and Critical Heat Flux
    DolatiAsl, K.
    Bakhshan, Y.
    Abedini, E.
    Niazi, S.
    INTERNATIONAL JOURNAL OF ENGINEERING, 2020, 33 (08): : 1590 - 1597
  • [5] Diameter effect on critical heat flux
    Tanase, A.
    Cheng, S. C.
    Groeneveld, D. C.
    Shan, J. Q.
    NUCLEAR ENGINEERING AND DESIGN, 2009, 239 (02) : 289 - 294
  • [6] Investigation of the Effect of Needle Diameter and the Solution Flow Rate on Fiber Morphology in the Electrospinning Method
    Gunduz, Gonca Simsek
    FIBRES & TEXTILES IN EASTERN EUROPE, 2023, 31 (04) : 22 - 29
  • [7] EXPERIMENTAL INVESTIGATION OF THE EFFECT OF LIQUID VISCOSITY ON SLUG FLOW IN SMALL DIAMETER BUBBLE COLUMN
    Kajero, Olumayowa Timothy
    Azzopardi, Barry John
    Abdulkareem, Lokman
    EFM11 - EXPERIMENTAL FLUID MECHANICS 2011, 2012, 25
  • [8] Determination of the critical flow pore diameter of shale caprock
    Ma, Cunfei
    Lin, Chengyan
    Dong, Chunmei
    Elsworth, Derek
    Wu, Songtao
    Wang, Xiaoqi
    Sun, Xiaolong
    MARINE AND PETROLEUM GEOLOGY, 2020, 112
  • [9] EFFECT OF TUBE DIAMETER .1. AN INVESTIGATION OF THE FLOW CHARACTERISTICS IN THE DISTURBANCE WAVE REGION OF ANNULAR-FLOW
    SEKOGUCHI, K
    TANAKA, O
    UENO, T
    FURUKAWA, T
    ESAKI, S
    NAKASATOMI, M
    BULLETIN OF THE JSME-JAPAN SOCIETY OF MECHANICAL ENGINEERS, 1983, 26 (220): : 1719 - 1726
  • [10] AN INVESTIGATION OF VERY SMALL DIAMETER LAMINAR FLOW ORIFICES
    DICKERSO.P
    RICE, W
    JOURNAL OF BASIC ENGINEERING, 1969, 91 (03): : 546 - &