3D Gamma Test for Patient Specific Quality Assurance of Proton Pencil Beam Scanning Dose

被引:0
|
作者
Pirelepesov, F. [1 ]
Yao, W. [1 ]
Ates, O. [1 ]
Lukose, R. [1 ]
Moskvin, V. [1 ]
Zhao, L. [1 ]
Farr, J. [1 ]
Merchant, T. [1 ]
机构
[1] St Jude Childrens Res Hosp, 332 N Lauderdale St, Memphis, TN 38105 USA
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-I-GPD-T
引用
收藏
页数:1
相关论文
共 50 条
  • [1] Beam Parameters of Pediatric Plans with a Pencil Beam Scanning Proton System and Their Effects On Patient-Specific Quality Assurance
    Al-ward, S.
    Zhao, L.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E710 - E710
  • [2] Validating a Monte Carlo approach to absolute dose quality assurance for proton pencil beam scanning
    Winterhalter, C.
    Fura, E.
    Tian, Y.
    Aitkenhead, A.
    Bolsi, A.
    Dieterle, M.
    Fredh, A.
    Meier, G.
    Oxley, D.
    Siewert, D.
    Weber, D. C.
    Lomax, A.
    Safai, S.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (17):
  • [3] Assessment of Monte Carlo Simulations as Alternative Reference for Patient Specific Quality Assurance in Pencil Beam Scanning Proton Therapy
    Shin, J.
    Jee, K.
    Clasie, B.
    Depauw, N.
    Madden, T.
    Paganetti, H.
    Kooy, H.
    [J]. MEDICAL PHYSICS, 2017, 44 (06)
  • [4] Analytic Dose Verification for Patient-Specific Proton Pencil Beam Scanning Plans
    Chang, C.
    Mah, D.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3359 - 3359
  • [5] Detectors for quality assurance of pencil beam scanning gantries for proton therapy
    Gagnon-Moisan, F.
    van der Meer, R.
    Chowdhuri, Z.
    Eichin, M.
    Koenig, S.
    Schmid, F. -J.
    Weber, D. C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S44 - S45
  • [6] Validation of Low-Dose-Tail Modeling for Proton Pencil Beam Spot Scanning Using a Quality Assurance Test Pattern
    Lin, L.
    Huang, S.
    Kang, M.
    Solberg, T.
    McDonough, J.
    Ainsley, C.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3208 - 3209
  • [7] Patient specific dosimetry and quality assurance for an active uniform scanning proton beam
    Mascia, A. E.
    Wolanski, M.
    Jesseph, R.
    Nichiporov, D.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S652 - S652
  • [8] Patient-Specific Quality Assurance in Pencil Beam Scanning by 2-Dimensional Array
    Rawiwan, Nuttida
    Chatchumnan, Nichakan
    Vimolnoch, Mananchaya
    Kingkaew, Sakda
    Oonsiri, Sornjarod
    [J]. INTERNATIONAL JOURNAL OF PARTICLE THERAPY, 2023, 10 (02) : 105 - 110
  • [9] Factors influencing the performance of patient specific quality assurance for pencil beam scanning IMPT fields
    Trnkova, P.
    Bolsi, A.
    Albertini, F.
    Weber, D. C.
    Lomax, A. J.
    [J]. MEDICAL PHYSICS, 2016, 43 (11) : 5998 - 6007
  • [10] Applications of a novel detector for pencil beam scanning proton therapy beam quality assurance
    Yang, Pei-Ying
    Hsieh, Yang-Wei
    Kang, Chen-Lin
    Tseng, Chin-Dar
    Lin, Chih-Hsueh
    Shieh, Chin-Shiuh
    Chao, Pei-Ju
    Lee, Tsair-Fwu
    [J]. INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2021, 35 (14N16):