Comparison of the KonRad IMRT and XiO treatment planning systems

被引:3
|
作者
Reitz, Bodo [1 ,2 ]
Miften, Moyed [1 ,2 ]
机构
[1] Allegheny Gen Hosp, Dept Radiat Oncol, Pittsburgh, PA 15212 USA
[2] Drexel Univ, Coll Med, Pittsburgh, PA USA
来源
关键词
TPS; IMRT; segmentation; QA;
D O I
10.1120/jacmp.v9i3.2770
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Reducing the treatment time for IMRT patients is highly desirable. The objective of this work was to evaluate the new clinical Siemens KonRad inverse treatment planning system (TPS) and compare it to the CMS XiO TPS with special emphasis on the segmentation efficiency. For head and neck, liver and prostate cancer patients, step-and-shoot IMRT plans were designed using both CMS XiO and Siemens KonRad TPS. Number, direction and energy of beams used were the same in the plans from both systems for each treatment site. The plans were optimized to achieve the same clinical objectives concerning dose to the target volume and to the relevant organs-at-risk (OARs). The number of intensity levels were minimized until the clinical objectives could not be achieved anymore. Dose-volume histograms (DVHs), mean and maximum doses were compared, as well as the number of beam segments and monitor units (MUs). The beams of each plan were delivered individually on a MapCheck device to verify the agreement between calculations and measurements to be less than 3%-3 mm distance-to-agreement. Plans optimized with KonRad resulted in fewer segments and lower number of MUs and therefore reduced delivery time on average by 28% or 3.6 min, while achieving similar dose distributions. CMS XiO plans exhibited a slightly steeper dose fall-off outside the target volumes; however the difference was not clinically significant. DVHs to OARs were comparable. All calculated dose distributions passed the 3%-3 mm verification check.
引用
收藏
页码:122 / 135
页数:14
相关论文
共 50 条
  • [1] Commissioning of modulator-based IMRT with XiO treatment planning system
    Oguchi, Hiroshi
    Obata, Yasunori
    [J]. MEDICAL PHYSICS, 2009, 36 (01) : 261 - 269
  • [2] Comparison of two commercial treatment planning systems for IMRT
    Petrie, M
    Robar, JL
    Clark, BG
    [J]. MEDICAL PHYSICS, 2003, 30 (07) : 1944 - 1944
  • [3] Comparison of two inverse IMRT treatment planning systems
    Yenice, K
    Chang, J
    Hong, L
    Braban, L
    Hunt, M
    Chui, C
    Amols, H
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1874 - 1874
  • [4] A comparison of two commercial IMRT treatment planning systems
    D'Souza, W
    Sarfaraz, M
    Naqvi, S
    [J]. MEDICAL PHYSICS, 2003, 30 (06) : 1486 - 1486
  • [5] Evaluation of the beam segmentation algorithm in the KonRad IMRT treatment planning system
    Reitz, B.
    Miften, M.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2593 - 2594
  • [6] Systematic comparison of IMRT modules in commercial treatment planning systems
    de Langen, M
    Vieira, S
    Seppenwoolde, Y
    Geelen, B
    Storchi, P
    Heijmen, B
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S41 - S41
  • [7] A comparison of two commercial treatment-planning systems for IMRT
    Petric, M. Peter
    Clark, Brenda G.
    Robar, James L.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2005, 6 (03): : 63 - 80
  • [8] Comparison of different IMRT treatment planning systems on pediatric cases
    Cozzi, A. Fogliata
    Asell, M.
    Clivio, A.
    Dobler, B.
    Larsson, M.
    Lohr, F.
    Lorenz, F.
    Muzik, J.
    Nicolini, G.
    Polednik, M.
    Vanetti, V.
    Wolff, D.
    Wyttenbach, R.
    Cozzi, L.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S408 - S408
  • [9] Implementation of carbon fibre treatment couches in the XiO® and Monaco® Treatment Planning Systems
    Van Reenen, Christoffel Jacobus
    Trauernicht, Christoph Jan
    [J]. POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2020, 26 (04): : 211 - 215
  • [10] Comparison of Treatment Planning Systems' shallow depth dose prediction for IMRT
    Bogaert, E.
    Pittomvils, G.
    De Wagter, C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S972 - S973