Measurements of dose-averaged linear energy transfer distributions in water using CR-39 plastic nuclear track detector for therapeutic carbon ion beams

被引:12
|
作者
Kohno, R
Yasuda, N
Takeshi, H
Kase, Y
Ochiai, K
Komori, M
Matsufuji, N
Kanai, T
机构
[1] Natl Inst Radiol Sci, Dept Med Phys, Chiba 2638555, Japan
[2] Natl Inst Radiol Sci, Res Ctr Radiat Safety, Chiba 2638555, Japan
[3] Univ Tsukuba, Grad Sch Pure & Appl Sci, Tsukuba, Ibaraki 3058573, Japan
[4] Tokyo Inst Technol, Interdisciplinary Grad Sch Sci & Engn, Yokohama, Kanagawa 2268502, Japan
[5] Toho Univ, Dept Phys, Chiba 2740072, Japan
[6] Natl Inst Radiol Sci, Dept Accelerator Phys & Engn, Chiba 2638555, Japan
来源
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS | 2005年 / 44卷 / 12期
关键词
CR-39 plastic nuclear track detector; dose-averaged LET; carbon ion radiotherapy; Bragg curve; depth-dose distribution; spread-out Bragg peak (SOBP);
D O I
10.1143/JJAP.44.8722
中图分类号
O59 [应用物理学];
学科分类号
摘要
A CR-39 plastic nuclear track detector was used as a linear energy transfer (LET) detector for carbon ion radiotherapy. We compared dose-averaged LET distributions in water obtained using the CR-39 detector for a monoenergetic beam and spreadout Bragg peak beam by calculations using the one-dimensional heavy-ion transport code used in the current heavy-ion treatment planning. We confirmed that the CR-39 detector could measure the high LET particles that are dominant contributors to dose-averaged LET. On the other hand, the CR-39 result was overestimated in the tail region of the distal edge in depth-dose distributions, due to its detection limit for lower LET particles. However, physical dose in the region is quite small. Namely, the effect of this difference on the biological dose distribution is also small. These results demonstrate that the CR-39 detector is a useful detector for measuring the LET distribution in carbon ion radiotherapy.
引用
收藏
页码:8722 / 8726
页数:5
相关论文
共 48 条
  • [21] Unresectable Chondrosarcomas Treated With Carbon Ion Radiotherapy: Relationship Between Dose-averaged Linear Energy Transfer and Local Recurrence
    Matsumoto, Shinnosuke
    Lee, Sung Hyun
    Imai, Reiko
    Inaniwa, Taku
    Matsufuji, Naruhiro
    Fukahori, Mai
    Kohno, Ryosuke
    Yonai, Shunsuke
    Okonogi, Noriyuki
    Yamada, Shigeru
    Kanematsu, Nobuyuki
    ANTICANCER RESEARCH, 2020, 40 (11) : 6429 - 6435
  • [22] Up modulation of dose-averaged linear energy transfer by simultaneous integrated boost in carbon-ion radiotherapy for pancreatic carcinoma
    Wang, Weiwei
    Sun, Jiayao
    Zhao, Jingfang
    Cheng, Jingyi
    Jiang, Guo-Liang
    Wang, Zheng
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (06):
  • [23] Effects of dose and dose-averaged linear energy transfer on pelvic insufficiency fractures after carbon-ion radiotherapy for uterine carcinoma
    Mori, Yasumasa
    Okonogi, Noriyuki
    Matsumoto, Shinnosuke
    Furuichi, Wataru
    Fukahori, Mai
    Miyasaka, Yuhei
    Murata, Kazutoshi
    Wakatsuki, Masaru
    Imai, Reiko
    Koto, Masashi
    Yamada, Shigeru
    Ishikawa, Hitoshi
    Kanematsu, Nobuyuki
    Tsuji, Hiroshi
    RADIOTHERAPY AND ONCOLOGY, 2022, 177 : 33 - 39
  • [24] Dose-averaged linear energy transfer per se does not correlate with late rectal complications in carbon-ion radiotherapy
    Okonogi, Noriyuki
    Matsumoto, Shinnosuke
    Fukahori, Mai
    Furuichi, Wataru
    Inaniwa, Taku
    Matsufuji, Naruhiro
    Imai, Reiko
    Yamada, Shigeru
    Kanematsu, Nobuyuki
    Tsuji, Hiroshi
    RADIOTHERAPY AND ONCOLOGY, 2020, 153 : 272 - 278
  • [25] Influence of dose-averaged linear energy transfer on tumour control after carbon-ion radiation therapy for pancreatic cancer
    Hagiwara, Yasuhito
    Bhattacharyya, Tapesh
    Matsufuji, Naruhiro
    Isozaki, Yuka
    Takiyama, Hirotoshi
    Nemoto, Kenji
    Tsuji, Hiroshi
    Yamada, Shigeru
    CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2020, 21 : 19 - 24
  • [26] TARGET FRAGMENTATION IN HIGH-ENERGY NUCLEUS-NUCLEUS COLLISIONS INVESTIGATED BY USING CR-39 PLASTIC TRACK DETECTOR
    GRABEZ, B
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1986, 12 (1-6): : 357 - 360
  • [27] Estimations of relative biological effectiveness of secondary fragments in carbon ion irradiation of water using CR-39 plastic detector and microdosimetric kinetic model
    Hirano, Yoshiyuki
    Kodaira, Satoshi
    Souda, Hikaru
    Osaki, Kohei
    Torikoshi, Masami
    MEDICAL PHYSICS, 2020, 47 (02) : 781 - 789
  • [28] IMAGING URANIUM DISTRIBUTION ON RAT KIDNEY SECTIONS THROUGH DETECTION OF ALPHA TRACKS USING CR-39 PLASTIC NUCLEAR TRACK DETECTOR
    Konishi, T.
    Kodaira, S.
    Itakura, Y.
    Ohsawa, D.
    Homma-Takeda, S.
    RADIATION PROTECTION DOSIMETRY, 2019, 183 (1-2) : 242 - 246
  • [29] Identification of nuclear fragments formed during fragmentation reaction with heavy ion beam using hybrid system of silver halide photography and plastic track detector CR-39
    Kuge, Ken'ichi
    Hayashi, Kentaro
    Endo, Yusuke
    Yasuda, Nakahiro
    Fukushima, Chika
    Shibuya, Hiroshi
    Hasegawa, Akira
    Kumagai, Hiroshi
    ICIS '06: INTERNATIONAL CONGRESS OF IMAGING SCIENCE, FINAL PROGRAM AND PROCEEDINGS: LINKING THE EXPLOSION OF IMAGING APPLICATIONS WITH THE SCIENCE AND TECHNOLOGY OF IMAGING, 2006, : 69 - 71
  • [30] MEASUREMENTS OF ELEMENTAL FRAGMENTATION CROSS-SECTION FOR RELATIVISTIC HEAVY-IONS USING CR-39 PLASTIC NUCLEAR TRACK DETECTORS
    BRECHTMANN, C
    HEINRICH, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1988, 29 (04): : 675 - 679