Noninvasive Blood Pressure Measurement Scheme Based on Optical Fiber Sensor

被引:1
|
作者
Liu Xianxuan [1 ]
Yuan Xueguang [1 ]
Zhang Yangan [1 ]
机构
[1] Beijing Univ Posts & Telecommun, Beijing, Peoples R China
关键词
optical fiber sensors technology; blood pressure measurement; automated analysis; partial least squares;
D O I
10.1117/12.2246910
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Optical fiber sensing has many advantages, such as volume small, light quality, low loss, strong in anti-jamming. Since the invention of the optical fiber sensing technology in 1977, optical fiber sensing technology has been applied in the military, national defense, aerospace, industrial, medical and other fields in recent years, and made a great contribution to parameter measurement in the environment under the limited condition. With the rapid development of computer, network system, the intelligent optical fiber sensing technology, the sensor technology, the combination of computer and communication technology, the detection, diagnosis and analysis can be automatically and efficiently completed. In this work, we proposed a noninvasive blood pressure detection and analysis scheme which uses optical fiber sensor. Optical fiber sensing system mainly includes the light source, optical fiber, optical detector, optical modulator, the signal processing module and so on. wavelength optical signals were led into the optical fiber sensor and the signals reflected by the human body surface were detected. By comparing actual testing data with the data got by traditional way to measure the blood pressure we can establish models for predicting the blood pressure and achieve noninvasive blood pressure measurement by using spectrum analysis technology. Blood pressure measurement method based on optical fiber sensing system is faster and more convenient than traditional way, and it can get accurate analysis results in a shorter period of time than before, so it can efficiently reduce the time cost and manpower cost.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Continuous measurement of blood oxygen pressure using a fiber optic sensor based on phosphorescence quenching
    Hase, K
    Sakai, S
    Tsukada, K
    Sekizuka, E
    Oshio, C
    Minamitani, H
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 1777 - 1778
  • [22] Novel integrated optical fiber sensor for temperature, pressure and flow measurement
    Zhao, Qiang
    Zheng, Hong-kun
    Lv, Ri-qing
    Gu, Ya-fei
    Zhao, Yong
    Yang, Yang
    SENSORS AND ACTUATORS A-PHYSICAL, 2018, 280 : 68 - 75
  • [23] Feasibility of Noninvasive Blood Pressure Measurement using a Chest-worn Patch Sensor
    Selvaraj, Nandakumar
    Reddivari, Hitesh
    2018 40TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2018, : 4961 - 4964
  • [24] OPTICAL FIBER PRESSURE MEASUREMENT
    MURPHY, MM
    JONES, GR
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1993, 4 (03) : 258 - 262
  • [25] NONINVASIVE LASER-BASED BLOOD-PRESSURE MEASUREMENT IN RABBITS
    HERROLD, EM
    GOLDWEIT, RS
    CARTER, JN
    ZUCCOTTI, G
    BORER, JS
    AMERICAN JOURNAL OF HYPERTENSION, 1992, 5 (03) : 197 - 202
  • [26] Development of optical fiber-based respiration sensor for noninvasive respiratory monitoring
    Wook Jae Yoo
    Kyoung Won Jang
    Jeong Ki Seo
    Ji Yeon Heo
    Jin Soo Moon
    Jae Hoon Jun
    Jang-Yeon Park
    Bongsoo Lee
    Optical Review, 2011, 18 : 132 - 138
  • [27] Development of Optical Fiber-Based Respiration Sensor for Noninvasive Respiratory Monitoring
    Yoo, Wook Jae
    Jang, Kyoung Won
    Seo, Jeong Ki
    Heo, Ji Yeon
    Moon, Jin Soo
    Jun, Jae Hoon
    Park, Jang-Yeon
    Lee, Bongsoo
    OPTICAL REVIEW, 2011, 18 (01) : 132 - 138
  • [28] Noninvasive Continuous Mobile Blood Pressure Monitoring using Novel PPG Optical Sensor
    Mouradian, Vahram
    Poghosyan, Armen
    Hovhannisyan, Levon
    2015 IEEE TOPICAL CONFERENCE ON BIOMEDICAL WIRELESS TECHNOLOGIES, NETWORKS, AND SENSING SYSTEMS (BIOWIRELESS), 2015, : 60 - 62
  • [29] NONINVASIVE BLOOD-PRESSURE MEASUREMENT IN THE NEONATE
    DARNALL, RA
    CLINICS IN PERINATOLOGY, 1985, 12 (01) : 31 - 49
  • [30] Numerical simulation of noninvasive blood pressure measurement
    Hayashi, Satoru
    Hayase, Toshiyuki
    Shirai, Atsushi
    Maruyama, Masaru
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (05): : 680 - 687