Improvement in magnetic field immunity of externally-coupled transcutaneous energy transmission system for a totally implantable artificial heart

被引:6
|
作者
Yamamoto, Takahiko [1 ]
Koshiji, Kohji [1 ]
Homma, Akihiko [2 ]
Tatsumi, Eisuke [2 ]
Taenaka, Yoshiyuki [2 ]
机构
[1] Tokyo Univ Sci, Grad Sch Sci & Technol, Noda, Chiba 2788510, Japan
[2] Natl Cardiovasc Ctr, Adv Med Engn Ctr, Osaka, Japan
关键词
Artificial heart; Transcutaneous energy transmission; Electromagnetic compatibility; Magnetic field immunity; Shield;
D O I
10.1007/s10047-008-0435-2
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Transcutaneous energy transmission (TET) that uses electromagnetic induction between the external and internal coils of a transformer is the most promising method to supply driving energy to a totally implantable artificial heart without invasion. Induction-heating (IH) cookers generate magnetic flux, and if a cooker is operated near a transcutaneous transformer, the magnetic flux generated will link with the external and internal coils of the transcutaneous transformer. This will affect the performance of the TET and the artificial heart system. Hence, it is necessary to improve the magnetic field immunity of the TET system. During operation of the system, if the transcutaneous transformer is in close proximity to an IH cooker, the electric power generated by the cooker and coupled to the transformer can drive the artificial heart system. To prevent this coupling, the external coil was shielded with a conductive shield that had a slit in it. This reduces the coupling between the transformer and the magnetic field generated by the induction cooker. However, the temperature of the shield increased due to heating by eddy currents. The temperature of the shield can be reduced by separating the IH cooker and the shield.
引用
收藏
页码:238 / 240
页数:3
相关论文
共 24 条
  • [21] Development and evaluation of totally implantable ventricular assist system using a vibrating flow pump and transcutaneous energy transmission system with amorphous fibers
    Yambe, T
    Hashimoto, H
    Kobayashi, S
    Sonobe, T
    Naganuma, S
    Nanka, S
    Matsuki, H
    Yoshizawa, M
    Tabayashi, K
    Takayasu, H
    Takeda, H
    Nitta, S
    HEART AND VESSELS, 1997, : 41 - 43
  • [22] TOTALLY IMPLANTABLE TOTAL ARTIFICIAL-HEART AND VENTRICULAR ASSIST DEVICE WITH MULTIPURPOSE MINIATURE ELECTROMECHANICAL ENERGY SYSTEM
    TAKATANI, S
    ORIME, Y
    TASAI, K
    OHARA, Y
    NAITO, K
    MIZUGUCHI, K
    MAKINOUCHI, K
    DAMM, G
    GLUECK, J
    LING, J
    NOON, G
    NOSE, Y
    ARTIFICIAL ORGANS, 1994, 18 (01) : 80 - 92
  • [23] A New Control Method Depending on Primary Phase Angle of Transcutaneous Energy Transmission System for Artificial heart
    Miura, H.
    Saito, I.
    Sato, F.
    Shiraishi, Y.
    Yambe, T.
    Matsuki, H.
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 5723 - 5726