A parametric study of linear and non-linear passively damped seismic isolation systems for buildings

被引:86
|
作者
Alhan, C [1 ]
Gavin, H [1 ]
机构
[1] Duke Univ, Dept Civil & Environm Engn, Durham, NC 27708 USA
基金
美国国家科学基金会;
关键词
seismic base isolation; viscous damping; hysteretic damping; vibration control; earthquake engineering;
D O I
10.1016/j.engstruct.2003.11.004
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The effects of near-field ground motions with large velocity pulses have motivated passive damping requirements for the protection of seismically isolated structures. Structures in which the first mode damping exceeds 20% or 30% typically do not exhibit classical modes, and simulation via a simple superposition of uncoupled second order equations is not possible. When the damping is produced by viscous or linear visco-elastic devices, we can, however, gain insight into the dynamic behavior of these structures using a convenient first-order formulation and frequency domain methods. When the damping effects are created by nonlinear mechanisms such as yielding or friction, the behavior of the structure is amplitude dependent and analyses are commonly carried out in the time domain. In this paper, frequency domain analysis and earthquake time history analysis are applied to study the influence of isolation damping on higher-mode effects and inter-story drift ratios. Because higher mode effects, plan irregularities, and bi-directional ground motions are all important attributes of the dynamic behavior of these structural systems, a simple comparison of isolation damping mechanisms can not be carried out via simple single or two degree of freedom realizations. In order to incorporate these important details in the study of the dynamic behavior of these structures, a set of 8-story proto-type building models with L-shaped floor plans, different isolation periods, isolation damping characteristics, and levels of isolation stiffnesses are examined. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:485 / 497
页数:13
相关论文
共 50 条
  • [21] Parametric control of the motions of non-linear oscillatory systems
    Akulenko, LD
    PMM JOURNAL OF APPLIED MATHEMATICS AND MECHANICS, 2001, 65 (01): : 1 - 11
  • [22] OPERATOR METHODS FOR STUDYING PARAMETRIC AND NON-LINEAR SYSTEMS
    PUKHOV, GE
    BEREGOVENKO, GY
    DOPOVIDI AKADEMII NAUK UKRAINSKOI RSR SERIYA A-FIZIKO-MATEMATICHNI TA TECHNICHNI NAUKI, 1979, (08): : 667 - 669
  • [23] NON-LINEAR AND PARAMETRIC PHENOMENA IN DISPERSIVE ACOUSTIC SYSTEMS
    OSTROVSKY, LA
    SOUSTOVA, IA
    SUTIN, AM
    ACUSTICA, 1978, 39 (05): : 298 - 306
  • [24] Parametric study of the non-linear seismic response of three-dimensional building models
    Fernández-Dávila, VI
    Cruz, EF
    ENGINEERING STRUCTURES, 2006, 28 (05) : 756 - 770
  • [25] Non-linear Methods for the Assessment of Seismic Vulnerability of Masonry Historical Buildings
    Croce, Pietro
    Landi, Filippo
    Formichi, Paolo
    Beconcini, Maria Luisa
    Puccini, Benedetta
    Zotti, Vincenzo
    PROTECTION OF HISTORICAL CONSTRUCTIONS, PROHITECH 2021, 2022, 209 : 651 - 670
  • [26] Seismic retrofit of existing buildings led by NON-LINEAR DYNAMIC analyses
    Porcu M.C.
    Vielma J.C.
    Panu F.
    Aguilar C.
    Curreli G.
    International Journal of Safety and Security Engineering, 2019, 9 (03) : 201 - 212
  • [27] On vibration isolation of mechanical systems with non-linear foundations
    Natsiavas, S
    Tratskas, P
    JOURNAL OF SOUND AND VIBRATION, 1996, 194 (02) : 173 - 185
  • [28] Non-linear energy dissipation in buildings: A comparative study
    Foti, D
    Bozzo, LM
    LopezAlmansa, F
    STRUCTURAL DYNAMICS, VOLS. 1 & 2, 1996, : 569 - 574
  • [29] STUDY OF A CLASS OF NON-LINEAR SYSTEMS REDUCIBLE TO EQUIVALENT LINEAR SYSTEMS
    DASARATHY, BV
    SRINIVASAN, P
    JOURNAL OF SOUND AND VIBRATION, 1968, 7 (01) : 27 - +
  • [30] SPECTRAL-ANALYSIS FOR NON-LINEAR SYSTEMS .1. PARAMETRIC NON-LINEAR SPECTRAL-ANALYSIS
    BILLINGS, SA
    TSANG, KM
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 1989, 3 (04) : 319 - 339