Influence of Aspect Ratios on the Creep Behaviour of Articular Cartilage in Indentation

被引:3
|
作者
Spoon, C. E.
Wayne, J. S.
机构
[1] Virginia Commonwealth Univ, Orthopaed Res Lab, Dept Biomed Engn, Richmond, VA USA
[2] Virginia Commonwealth Univ, Orthopaed Res Lab, Dept Orthopaed Surg, Richmond, VA USA
关键词
Finite Element Analysis; Indentation; Articular Cartilage; Poisson's ratio;
D O I
10.1080/10255840410001653087
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Indentation tests are commonly used to determine the mechanical behaviour of articular cartilage with varying properties, thickness, and geometry. This investigation evaluated the effect of changing geometric parameters on the properties determined from creep indentation tests. Finite element analyses simulated the indentation behaviour of two models, an excised cylindrical specimen of cartilage with either normal and repair qualities and an osteochondral defect represented as a cylindrical region of repair cartilage integrated with a surrounding layer of normal tissue. For each model, the ratios of indenter radius to cartilage height (a/h = 0,5, 1.5) and cartilage radius to indenter radius (r/a = 2, 5) were varied. The vertical displacement of the cartilage under the indenter obtained through finite element analysis was fitted to a numerical algorithm to determine the aggregate modulus, permeability, and Poisson's ratio. Indentation behaviours of cartilage specimens for either model with a/h = 1.5 were not affected by r/a for values of 2 and 5. Aggregate modulus was not greatly affected by the geometric changes studied. Permeability was affected by changes in the ratio of specimen to indenter radii for a/h = 0.5. These findings suggest that experimental configurations of excised cylindrical specimens, also representing osteochondral defects with no or unknown degree of integration, where the cartilage layer has a/h = 0.5 should not have r/a values on the order of 2 for confidence in the mechanical properties determined. Indentation of osteochondral defects where the repair cartilage is fully integrated to the surrounding cartilage can be performed with confidence for all cases tested.
引用
收藏
页码:17 / 23
页数:7
相关论文
共 50 条
  • [31] Optimization of In Situ Indentation Protocol to Map the Mechanical Properties of Articular Cartilage
    Berni, Matteo
    Erani, Paolo
    Lopomo, Nicola Francesco
    Baleani, Massimiliano
    [J]. MATERIALS, 2022, 15 (18)
  • [32] Investigation of creep behaviour under load during indentation experiments and its influence on hardness and modulus results
    Chudoba, T
    Richter, F
    [J]. SURFACE & COATINGS TECHNOLOGY, 2001, 148 (2-3): : 191 - 198
  • [33] Experimental characterization of flat indentation creep behaviour of Inconel 617
    Wei, Yugao
    Yang, Sisheng
    Xu, Hai
    Ling, Xiang
    [J]. VACUUM, 2023, 208
  • [34] Investigation of the biomechanical behaviour of articular cartilage in hindfoot joints
    Venturato, Chiara
    Pavan, Piero Giovanni
    Forestiero, Antonella
    Carniel, Emanuele Luigi
    Natali, Arturo Nicola
    [J]. ACTA OF BIOENGINEERING AND BIOMECHANICS, 2014, 16 (02) : 57 - 65
  • [35] Uncertainties in indentation testing of articular cartilage: A fibril-reinforced poroviscoelastic study
    Julkunen, Petro
    Korhonen, Rami K.
    Herzog, Walter
    Jurvelin, Jukka S.
    [J]. MEDICAL ENGINEERING & PHYSICS, 2008, 30 (04) : 506 - 515
  • [36] BIPHASIC INDENTATION OF ARTICULAR-CARTILAGE .1. THEORETICAL-ANALYSIS
    MAK, AF
    LAI, WM
    MOW, VC
    [J]. JOURNAL OF BIOMECHANICS, 1987, 20 (07) : 703 - 714
  • [37] Poromechanical Modeling of Porcine Knee Joint Using Indentation Map of Articular Cartilage
    Zare, Mojtaba
    Tang, Daniel
    Li, LePing
    [J]. COMPUTER METHODS, IMAGING AND VISUALIZATION IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2020, 36 : 86 - 106
  • [38] The accuracy and reliability of a novel handheld dynamic indentation probe for analysing articular cartilage
    Appleyard, RC
    Swain, MV
    Khanna, S
    Murrell, GAC
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (02): : 541 - 550
  • [39] Regional variations of indentation stiffness and thickness of normal rabbit knee articular cartilage
    Rasanen, T
    Messner, K
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1996, 31 (04): : 519 - 524
  • [40] Sensitivity of a hand-held indentation probe for measuring the stiffness of articular cartilage
    Niederauer, GG
    Niederauer, GM
    Cullen, LC
    Athanasiou, KA
    Thomas, JB
    Niederauer, MW
    [J]. SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 2591 - 2592