Adaptive two-loop power tracking control in CDMA systems with the utility optimization

被引:11
|
作者
Chen, Bor-Sen [1 ]
Yang, Chang-Yi
Li, Shin-Ye [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Elect Engn, Hsinchu, Taiwan
关键词
DS-CDMA; two-loop power control scheme; adaptive prediction control; optimal net utility;
D O I
10.1109/TWC.2008.060915
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An adaptive two-loop power tracking control scheme is proposed for direct sequence code-division multiple-access (DS-CDMA) cellular systems in a wireless network. The scheme includes an outer-loop controller and an inner-loop controller. An adaptive searching algorithm is designed for determining an optimal target signal to interference and noise ratio (SINR) for each user in the outer loop. The utility optimization can be achieved by using the adaptive algorithm through the net utility function based on the quality of service (QoS) for the purpose of resource management of wireless communication networks. A prediction control is designed to compensate for the effect of round-trip time-delay, channel fading, multiple access interference (MAI), and noise in the inner loop. The optimal target SINR tracking can be achieved by using the prediction control through a robust pole placement. Combining these two controllers in the outer loop and inner loop, utility optimization and target SINR tracking can be achieved at the same time. The stability and convergence of the proposed scheme are discussed. Several simulation results are given to confirm the performance of the proposed method.
引用
收藏
页码:1358 / 1368
页数:11
相关论文
共 50 条
  • [41] A novel two-loop large offset tracking control of an uncertain nonlinear system with input constraints
    Wang, Peng
    Zhang, Xiaobing
    Zhu, Jihong
    FUZZY SETS AND SYSTEMS, 2019, 374 : 82 - 99
  • [42] A novel two-loop large offset tracking control of an uncertain nonlinear system with input constraints
    Wang P.
    Zhang X.
    Zhu J.
    Fuzzy Sets and Systems, 2019, 374 : 82 - 99
  • [43] Problems of Self-containment in Connected Two-loop Automatic Control Systems of Modern Power Plant Units.
    Bilenko, V.A.
    Davydov, N.I.
    Teploenergetika, 1979, (12): : 32 - 38
  • [44] A new user mobility based adaptive power control in CDMA systems
    Lee, H
    Cho, DH
    IEICE TRANSACTIONS ON COMMUNICATIONS, 2003, E86B (05) : 1702 - 1705
  • [45] Fuzzy Logic based Closed Loop Adaptive Power Control for minimization of Near-far Interference in CDMA systems
    Singh, Kuldeep
    Dhillon, Kanwarpal Singh
    Singh, Komaljit
    2015 2ND INTERNATIONAL CONFERENCE ON RECENT ADVANCES IN ENGINEERING & COMPUTATIONAL SCIENCES (RAECS), 2015,
  • [46] Two-Loop Real-Coded Genetic Algorithms with Adaptive Control of Mutation Step Sizes
    F. Herrera
    M. Lozano
    Applied Intelligence, 2000, 13 : 187 - 204
  • [47] Adaptive two-loop voltage-mode control of DC-DC switching converters
    Figueres, E
    Garcerá, G
    Benavent, JM
    Pascual, M
    Martínez, JA
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (01) : 239 - 253
  • [48] Two-loop real-coded genetic algorithms with adaptive control of mutation step sizes
    Herrera, F
    Lozano, M
    APPLIED INTELLIGENCE, 2000, 13 (03) : 187 - 204
  • [49] Error probability analysis for CDMA systems with closed-loop power control
    De Fina, S
    Lombardo, P
    IEEE TRANSACTIONS ON COMMUNICATIONS, 2001, 49 (10) : 1801 - 1811
  • [50] Open-loop power control error in cellular CDMA overlay systems
    Wang, JZ
    Yu, A
    IEEE JOURNAL ON SELECTED AREAS IN COMMUNICATIONS, 2001, 19 (07) : 1246 - 1254