The Effect of Height and Weight Adjusted Dose of Intrathecal Hyperbaric Bupivacaine for Elective Caesarean Section

被引:0
|
作者
Subedi, A. [1 ]
Tripathi, M. [2 ]
Bhattarai, B. K. [1 ]
Gupta, P. K. [3 ]
Pokharel, K. [1 ]
Regmi, M. C. [4 ]
机构
[1] BPKIHS, Dept Anaesthesiol & Crit Care, Dharan, Nepal
[2] SGPGI, Dept Anaesthesiol, Lucknow, Uttar Pradesh, India
[3] BHU, Inst Med Sci, Dept Anaesthesiol, Varanasi, Uttar Pradesh, India
[4] BPKIHS, Dept Obstet & Gynaecol, Dharan, Nepal
关键词
caesarean section; low-dose hyperbaric bupivacaine; spinal anesthesia; SPINAL-ANESTHESIA; PATIENT VARIABLES; RISK-FACTORS; HYPOTENSION; DELIVERY; EPHEDRINE; PHENYLEPHRINE; PLAIN;
D O I
暂无
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Introduction: The study compared spinal anesthesia using intrathecal hyperbaric bupivacaine between height and weight adjusted dose and fixed dose during caesarean section. Methods: A hundred parturients, who had given their consent and were scheduled for elective caesarean section under spinal anesthesia, were randomly assigned into two groups. We adjusted the intrathecal dose of heavy bupivacaine (0.5 %) according to the height and weight of patients (Group AD) from Harten's dose chart developed from the Caucasian parturients and the fixed dose (2.2 ml) was used in Group FD patients. Keeping the observer blinded to the study groups, the onset time to sensory block up to T5, haemodynamic changes, side effects, and fetal outcome were observed. Results: The median onset time of spinal block in Group FD was faster than in Group AD (6 min vs. 4 min; p = 0.01). The spinal block level extended above T3 level in a significantly (p < 0.05) larger number of patients 12 (24 %) in Group FD than in one (2 %) patient in Group AD. A significantly (p < 0.05) larger number of patients, 32, (64 %) in Group FD had hypotension than in 15 (30 %) patients in Group AD. The lowest recorded SAP (101 +/- 6 mm Hg) in Group AD was higher than in Group FD (96 +/- 6.7 mm Hg). Nausea and vomiting were more pronounced in Group FD patients. Conclusions: The bupivacaine dose was significantly reduced on its dose adjustment for the body weight and height of patients for cesearean section. This adjusted-dose use suitably restricted spinal block level for cesarean section with a distinct advantage of less hypotension and with a similar neonatal outcome as fixed compared with the dose use.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [21] The effect of intrathecal dexmedetomidine on the dose requirement of hyperbaric bupivacaine in spinal anaesthesia for caesarean section: a prospective, double-blinded, randomized study
    Feng Xia
    Xiangyang Chang
    Yinfa Zhang
    Lizhong Wang
    Fei Xiao
    BMC Anesthesiology, 18
  • [22] The effect of intrathecal dexmedetomidine on the dose requirement of hyperbaric bupivacaine in spinal anaesthesia for caesarean section: a prospective, double-blinded, randomized study
    Xia, Feng
    Chang, Xiangyang
    Zhang, Yinfa
    Wang, Lizhong
    Xiao, Fei
    BMC ANESTHESIOLOGY, 2018, 18
  • [23] Abdominal girth and vertebral column length aid in predicting intrathecal hyperbaric bupivacaine dose for elective cesarean section
    Wei, Chang-Na
    Zhou, Qing-He
    Wang, Li-Zhong
    MEDICINE, 2017, 96 (34)
  • [24] Height Adjusted Doses of Bupivacaine in Caesarean Section and Association with Hypotension, Nausea and Vomitting
    Sabale, Parag
    Deshmukh, Pratibha
    Kirtigujarkar
    Deshmukh, Priyanka
    Chakole, Vivek
    ANNALS OF MEDICAL AND HEALTH SCIENCES RESEARCH, 2021, 11
  • [25] Weight and height adjusted dose regimen or fixed ED95 dose of intrathecal hyperbaric bupivacaine for cesarean delivery in parturients with different BMIs: which would be optimal?
    Gunaydin, Dudu Berrin
    CURRENT MEDICAL RESEARCH AND OPINION, 2023, 39 (02) : 329 - 330
  • [26] Reply to: Weight and height adjusted dose regimen or fixed ED95 dose of intrathecal hyperbaric bupivacaine for cesarean delivery in parturients with different BMIs: which would be optimal?
    Ravindranath, Sapna
    Ituk, Unyime S.
    CURRENT MEDICAL RESEARCH AND OPINION, 2022, 38 (11) : 2011 - 2012
  • [27] Intrathecal clonidine with hyperbaric bupivacaine administered as a mixture and sequentially in caesarean section: A randomised controlled study
    Sachan, Prachee
    Kumar, Nidhi
    Sharma, J. P.
    INDIAN JOURNAL OF ANAESTHESIA, 2014, 58 (03) : 287 - 292
  • [28] Comparison of Equivalent Doses of Intrathecal Hyperbaric Levo-bupivacaine and Hyperbaric Bupivacaine for Caesarean Section: A Prospective Randomised Double-Blind Study
    Saring, Noyomi
    Namdeo, Animesh
    Apo, Millo
    Sanyal, Ramapati
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2024, 18 (03) : UC6 - UC9
  • [29] Comparison of equipotent doses of intrathecal hyperbaric prilocaine 2% and hyperbaric bupivacaine 0.5% for elective caesarean section A prospective, randomised, controlled, two-centre clinical trial
    Goffard, Philippe
    Leloup, Renaud
    Vercruysse, Yoann
    Fils, Jean-Francois
    Gautier, Philippe Emmanuel
    Kapessidou, Yota
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2022, 39 (03) : 227 - 235
  • [30] Estimation of the dose of hyperbaric bupivacaine for spinal anaesthesia for emergency caesarean section in an achondroplastic dwarf
    Samra, Tanvir
    Sharma, Sujata
    INDIAN JOURNAL OF ANAESTHESIA, 2010, 54 (05) : 481 - +