Cerebral blood flow measured by transcranial Doppler ultrasound during manual chest wall or automated LUCAS-2 compressions during cardiopulmonary resuscitation

被引:0
|
作者
Carmona Jimenez, Francesc [1 ]
Palma Padro, Pilar [1 ]
Soto Garcia, Angeles [1 ]
Rodriguez Venegas, Juan Carlos [1 ]
机构
[1] SEM, Barcelona, Spain
来源
EMERGENCIAS | 2012年 / 24卷 / 01期
关键词
Brain ischemia; Chest wall compression; Cardiopulmonary resuscitation; Transcranial Doppler ultrasound; QUALITY; DEVICE;
D O I
暂无
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Effective chest wall compressions are essential to ensure a minimum of cerebral blood flow during resuscitation, but manual compression maneuvers are not always efficacious. The LUCAS system delivers chest wall compressions that comply with international recommendations. Using transcranial Doppler ultrasound to measure cerebral blood flow, we compared flow during the cardiopulmonary resuscitation of 6 patients before and after placement of the LUCAS device. Two of the patients in cardiorespiratory arrest secondary to subarachnoid bleeding had no cerebral blood flow with either manual or automated compressions. For the other 4 patients, cerebral blood flow was better during the automated compressions from the LUCAS system. [Emergencias 2012;24:47-49]
引用
收藏
页码:47 / 49
页数:3
相关论文
共 50 条
  • [21] CEREBRAL BLOOD-FLOW DURING CONVENTIONAL, NEW AND OPEN-CHEST CARDIOPULMONARY RESUSCITATION IN DOGS
    ARAI, T
    DOTE, K
    TSUKAHARA, I
    NITTA, K
    NAGARO, T
    RESUSCITATION, 1984, 12 (02) : 147 - 154
  • [22] Assessment of cerebral blood flow velocity by transcranial Doppler ultrasound during maximal bicycle ergometry
    Olson, TP
    Schlick, LM
    Dengel, DR
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2004, 36 (05): : S22 - S22
  • [23] Transcranial doppler blood flow velocity versus xenon clearance cerebral blood flow during mild hypothermic cardiopulmonary bypass
    Grocott, HP
    Lowry, E
    Croughwell, ND
    White, WD
    Newman, MF
    ANESTHESIA AND ANALGESIA, 1997, 84 : S82 - S82
  • [24] PULSATILE FLOW PATTERN IN CEREBRAL-ARTERIES DURING CARDIOPULMONARY BYPASS - AN EVALUATION BASED ON TRANSCRANIAL DOPPLER ULTRASOUND
    KAPS, M
    HAASE, A
    MULCH, J
    STERTMANN, WA
    THIEL, A
    JOURNAL OF CARDIOVASCULAR SURGERY, 1989, 30 (01): : 16 - 19
  • [25] ESTIMATION OF CEREBRAL BLOOD-FLOW DURING CARDIOPULMONARY RESUSCITATION IN HUMANS
    CHRISTENSEN, SF
    STADEAGER, C
    SIEMKOWICZ, E
    RESUSCITATION, 1990, 19 (02) : 115 - 123
  • [26] SUPERIOR MYOCARDIAL PERFUSION WITH OPEN CHEST CARDIAC MASSAGE VERSUS RAPID MANUAL EXTERNAL CHEST COMPRESSIONS DURING PROLONGED CARDIOPULMONARY RESUSCITATION
    KERN, KB
    SANDERS, AB
    NELSON, J
    EWY, GA
    CLINICAL RESEARCH, 1990, 38 (02): : A340 - A340
  • [27] Ultrasound guided chest compressions during cardiopulmonary resuscitation (vol 87, pg e13, 2015)
    Zanatta, Mirko
    Benato, Piero
    Cianci, Vito
    RESUSCITATION, 2015, 89 : 19 - 19
  • [28] First in Man Study of Ultrasound to Measure Blood Flow During Cardiopulmonary Resuscitation
    Adedipe, Adeyinka
    Fly, Deborah
    Schwitz, Scott
    Duric, Hans
    Jorgenson, Dawn
    Sayre, Michael
    Nichol, Graham
    CIRCULATION, 2014, 130
  • [29] Relationship between hemodynamic parameters and cerebral blood flow during cardiopulmonary resuscitation
    Debaty, Guillaume
    Moore, Johanna
    Duhem, Helene
    Rojas-Salvador, Carolina
    Salverda, Bayert
    Lick, Mike
    Labarere, Jose
    Lurie, Keith G.
    RESUSCITATION, 2020, 153 : 20 - 27
  • [30] INTERPOSED ABDOMINAL COMPRESSIONS AND CAROTID BLOOD-FLOW DURING CARDIOPULMONARY RESUSCITATION - SUPPORT FOR A THORACOABDOMINAL UNIT
    EINAGLE, V
    BERTRAND, F
    WISE, RA
    ROUSSOS, C
    MAGDER, S
    CHEST, 1988, 93 (06) : 1206 - 1212