Multisoftware Reproducibility Study of Stress and Rest Myocardial Blood Flow Assessed with 3D Dynamic PET/CT and a 1-Tissue-Compartment Model of 82Rb Kinetics

被引:96
|
作者
deKemp, Robert A. [1 ]
Declerck, Jerome [2 ]
Klein, Ran [1 ]
Pan, Xiao-Bo [2 ]
Nakazato, Ryo [3 ]
Tonge, Christine [4 ]
Arumugam, Parthiban [4 ]
Berman, Daniel S. [3 ]
Germano, Guido [3 ]
Beanlands, Rob S. [1 ]
Slomka, Piotr J. [3 ]
机构
[1] Univ Ottawa, Inst Heart, Natl Cardiac PET Ctr, Ottawa, ON K1Y 4W7, Canada
[2] Siemens Healthcare Mol Imaging, Oxford, England
[3] Cedars Sinai Med Ctr, Los Angeles, CA 90048 USA
[4] NHS Fdn Trust, Cent Manchester Univ Hosp, Manchester, Lancs, England
关键词
myocardial blood flow quantification; myocardial perfusion imaging; rubidium positron emission tomography; coronary flow reserve; myocardial perfusion reserve; POSITRON-EMISSION-TOMOGRAPHY; PERFUSION; QUANTIFICATION; N-13-AMMONIA; RESERVE; ACCURACY; SPECT;
D O I
10.2967/jnumed.112.112219
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Routine quantification of myocardial blood flow (MBF) requires robust and reproducible processing of dynamic image series. The goal of this study was to evaluate the reproducibility of 3 highly automated software programs commonly used for absolute MBF and flow reserve (stress/rest MBF) assessment with Rb-82 PET imaging. Methods: Dynamic rest and stress Rb-82 PET scans were selected in 30 sequential patient studies performed at 3 separate institutions using 3 different 3-dimensional PET/CT scanners. All 90 scans were processed with 3 different MBF quantification programs, using the same 1-tissue-compartment model. Global (left ventricle) and regional (left anterior descending, left circumflex, and right coronary arteries) MBF and flow reserve were compared among programs using correlation and Bland-Altman analyses. Results: All scans were processed successfully by the 3 programs, with minimal operator interactions. Global and regional correlations of MBF and flow reserve all had an R-2 of at least 0.92. There was no significant difference in flow values at rest (P = 0.68), stress (P = 0.14), or reserve (P = 0.35) among the 3 programs. Bland-Altman coefficients of reproducibility (1.96 x SD) averaged 0.26 for MBF and 0.29 for flow reserve differences among programs. Average pairwise differences were all less than 10%, indicating good reproducibility for MBF quantification. Global and regional SD from the line of perfect agreement averaged 0.15 and 0.17 mL/min/g, respectively, for MBF, compared with 0.22 and 0.26, respectively, for flow reserve. Conclusion: The 1-tissue-compartment model of Rb-82 tracer kinetics is a reproducible method for quantification of MBF and flow reserve with 3-dimensional PET/CT imaging.
引用
收藏
页码:571 / 577
页数:7
相关论文
共 37 条
  • [11] 3D versus 2D dynamic 82Rb myocardial blood flow imaging in a canine model of stunned and infarcted myocardium
    Lekx, Katie S.
    deKemp, Robert A.
    Beanlands, Rob S. B.
    Wisenberg, Gerald
    Wells, Glenn
    Stodilka, Robert Z.
    Lortie, Mireille
    Klein, Ran
    Zabel, Pamela
    Kovacs, Michael S.
    Sykes, Jane
    Prato, Frank S.
    NUCLEAR MEDICINE COMMUNICATIONS, 2010, 31 (01) : 75 - 81
  • [12] 3D PET/CT 82Rb PET myocardial blood flow quantification: comparison of half-dose and full-dose protocol.
    Lassen, Martin Lyngby
    Manabe, Osamu
    Otaki, Yuka
    Eisenberg, Evann
    Wang, Frances
    Phi Huynh
    Berman, Daniel
    Slomka, Piotr
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [13] Automatic 3D registration of dynamic stress and rest 82Rb and flurpiridaz F 18 myocardial perfusion PET data for patient motion detection and correction
    Woo, Jonghye
    Tamarappoo, Balaji
    Dey, Damini
    Nakazato, Ryo
    Le Meunier, Ludovic
    Ramesh, Amit
    Lazewatsky, Joel
    Germano, Guido
    Berman, Daniel S.
    Slomka, Piotr J.
    MEDICAL PHYSICS, 2011, 38 (11) : 6313 - 6326
  • [14] Myocardial flow reserve assessed by Cardiac 82Rb PET/CT is associated with albumin excretion in patients with type 1 diabetes
    Zobel, E. Hein
    Winther, S. Abitz
    Hasbak, P.
    von Scholten, B.
    Holmvang, L.
    Kjaer, A.
    Rossing, R.
    Hansen, T.
    DIABETOLOGIA, 2018, 61 : S531 - S531
  • [15] MYOCARDIAL FLOW RESERVE ASSESSED BY CARDIAC 82RB PET/CT IS ASSOCIATED WITH ALBUMIN EXCRETION IN PATIENTS WITH TYPE 1 DIABETES
    Hansen, Tine
    Zobel, Emilie H.
    Winther, Signe A.
    Hasbak, Philip
    von Scholten, Bernt J.
    Holmvang, Lene
    Kjaer, Andreas
    Rossing, Peter
    Hansen, Tine Willum
    JOURNAL OF HYPERTENSION, 2018, 36 : E147 - E147
  • [16] Effect of stress/rest peak ratio of the arterial input curves on diagnostic performance of 82Rb PET myocardial blood flow quantification
    Fujito, Hidesato
    Zhang, Wenhao
    Lemley, Mark
    Kuronuma, Keiichiro
    Killekar, Aditya
    Builoff, Valerie
    Kavanagh, Paul
    Hyun, Mark
    Hayes, Sean
    Thomson, Louise
    Friedman, John
    Van Kriekinge, Serge
    Di Carli, Marcelo Fernando
    Dey, Damini
    Berman, Daniel
    Slomka, Piotr
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [18] Myocardial blood flow quantification by Rb-82 cardiac PET/CT: Methodological issues on reproducibility study
    Siamak Sabour
    Journal of Nuclear Cardiology, 2017, 24 : 1831 - 1831
  • [19] Effects of two patient-specific dosing protocols on measurement of myocardial blood flow with 3D 82Rb cardiac PET
    Liliana Arida-Moody
    Jonathan B Moody
    Jennifer M Renaud
    Alexis Poitrasson-Rivière
    Tomoe Hagio
    Anne M Smith
    Edward P Ficaro
    Venkatesh L Murthy
    European Journal of Nuclear Medicine and Molecular Imaging, 2021, 48 : 3835 - 3846
  • [20] Effects of two patient-specific dosing protocols on measurement of myocardial blood flow with 3D 82Rb cardiac PET
    Arida-Moody, Liliana
    Moody, Jonathan B.
    Renaud, Jennifer M.
    Poitrasson-Riviere, Alexis
    Hagio, Tomoe
    Smith, Anne M.
    Ficaro, Edward P.
    Murthy, Venkatesh L.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (12) : 3835 - 3846