Screw Placement in Subtalar Arthrodesis: A Biomechanical Study

被引:44
|
作者
Chuckpaiwong, Bavornrit [1 ]
Easley, Mark E. [1 ]
Glisson, Richard R. [1 ]
机构
[1] Duke Univ, Med Ctr, Div Orthopaed Surg, Durham, NC 27710 USA
关键词
Subtalar; Screw; Arthrodesis; Fusion; Talus; ANKLE ARTHRODESIS; JOINT; COMPRESSION; BONE; KINEMATICS; MOBILITY; COMPLEX;
D O I
10.3113/FAI.2009.0133
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Clinical outcomes of subtalar arthrodesis using screw fixation have been reported but biomechanical support for selection of screw trajectories and patterns has been lacking. This investigation was designed to assess the compressive and stabilizing abilities of different common screw insertion patterns for subtalar arthrodesis. Materials and Methods: Forty-two cadaveric subtalar joints underwent arthrodesis with a single talar neck screw, a single talar dome screw, double parallel screws, or double diverging screws. Single talar dome screw fixation was subdivided by screw tip placement in the anteromedial, posteromedial, anterolateral, or posterolateral dome. Joint compression, construct torsional stiffness, and joint angulation tinder torsional load were quantified. Results: Higher compressive force, torsional stiffness, and joint rotation resistance were achieved by double screw fixation compared to single screws (p < 0.001). Torsional stiffness with double diverging screws exceeded that of double parallel screws in internal rotation (p < 0.05). There was greater internal rotation with a single talar neck screw (p < 0.001) and greater external rotation with an anterolateral talar dome screw (p < 0.01) compared to the other single-screw orientations. Greater rotation in both directions was noted with the single screw tip located in the posterolateral talar dome (p < 0.01). Conclusion: Under the described testing conditions, double diverging screws confer the highest compression, the greatest torsional stiffness, and the least joint rotation. When a single screw is used, placement of the screw tip in the talar neck or lateral talar dome should be avoided. Clinical Relevance: The results provide an objective basis for selection of optimal screw placement by the surgeon.
引用
收藏
页码:133 / 141
页数:9
相关论文
共 50 条
  • [21] Erratum to: Optimal double screw configuration for subtalar arthrodesis: a finite element analysis
    Jun Young Lee
    Yeon Soo Lee
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2011, 19 : 867 - 867
  • [22] CLINICAL-STUDY OF BACHELOR SUBTALAR ARTHRODESIS
    GROSS, RH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1976, 58 (03): : 343 - 349
  • [23] SUBTALAR ARTHRODESIS IN CHILDREN
    GALLIEN, R
    MORIN, F
    MARQUIS, F
    [J]. JOURNAL OF PEDIATRIC ORTHOPAEDICS, 1989, 9 (01) : 59 - 63
  • [24] Subtalar joint arthrodesis
    Catanzariti, AR
    Mendicino, RW
    Saltrick, KR
    Orsini, RC
    Dombek, MF
    Lamm, BM
    [J]. JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 2005, 95 (01) : 34 - 41
  • [25] Subtalar Distraction Arthrodesis
    Probe, Robert
    Brown, Jaycen C.
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2021, 35 : S54 - S55
  • [26] Subtalar Joint Arthrodesis
    Lopez, Ramon
    Singh, Tarika
    Banga, Samantha
    Hasan, Nafisa
    [J]. CLINICS IN PODIATRIC MEDICINE AND SURGERY, 2012, 29 (01) : 67 - +
  • [27] GRICE SUBTALAR ARTHRODESIS
    SANPERA, I
    HOFFMAN, EB
    SINGER, M
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (03): : 501 - 501
  • [28] INDICATION FOR SUBTALAR ARTHRODESIS
    HOLZ, U
    [J]. ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 1975, 113 (04): : 681 - 684
  • [29] ISOLATED SUBTALAR ARTHRODESIS
    Ferrao, Paulo N.
    Saragas, Nikiforos P.
    Strydom, Andrew
    [J]. JBJS ESSENTIAL SURGICAL TECHNIQUES, 2016, 6 (01):
  • [30] Isolated subtalar arthrodesis
    Easley, ME
    Trnka, HJ
    Schon, LC
    Myerson, MS
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (05): : 613 - 624