Quantifying the contribution of pincer deformity to femoro-acetabular impingement using 3D computerised tomography

被引:26
|
作者
Dandachli, Wael [1 ]
Najefi, Ali [1 ]
Iranpour, Farhad [1 ]
Lenihan, Jonathan [1 ]
Hart, Alister [1 ]
Cobb, Justin [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Charing Cross Hosp, Dept Orthopaed Surg, London W6 8RF, England
关键词
Acetabular protrusio; Centre-edge angle; Femoral head coverage; Computerized tomography; CENTER-EDGE ANGLE; FEMOROACETABULAR IMPINGEMENT; PROTRUSIO-ACETABULI; RHEUMATOID-ARTHRITIS; ADULT HIP; OSTEOARTHRITIS; MORPHOLOGY; DYSPLASIA;
D O I
10.1007/s00256-012-1389-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
To provide a simple, reliable method for the three-dimensional quantification of pincer-type hip deformity. Computerised tomography scans of 16 normal female hips and 15 female hips with clinical femoro-acetabular impingement (FAI) and radiographic signs of pincer secondary to acetabular protrusio were analysed. After orientating the pelvis in the anterior pelvic plane, the acetabular centre was determined, and the ratios of its coordinates to the corresponding pelvic dimensions were calculated. Acetabular coverage of the femoral head and centre-edge angles were also measured for the two groups. In hips with a pincer, the hip was medialised by 37 % (p = 0.03), more proximal by 5 % (p = 0.05) and more posterior by 9 % (p = 0.03) compared with the normal hips. Coverage of the femoral head in protrusio hips was significantly greater than normal (average 71 % vs 82 %, p = 0.0001). Both the lateral centre-edge angle and the combined anterior-posterior centre-edge angle were greater in protrusio hips than in the normal ones (48A degrees vs 37 A degrees, p < 0.001; and 216A degrees vs 176A degrees, p < 0.0001 respectively). Displacement in acetabular protrusio occurs in all planes. This CT-based method allows for the accurate and standardised quantification of the extent of displacement, as well as 3D measurement of femoral head coverage. In the adult female population, a combined centre-edge angle of over 190A degrees suggests an acetabulum that is too deep and a potential cause of symptoms of femoro-acetabular impingement. Conversely, an acetabulum that has a combined centre-edge angle of less than 190A degrees may be considered to be of normal depth, and therefore not contributing a pincer to FAI should it occur.
引用
收藏
页码:1295 / 1300
页数:6
相关论文
共 50 条
  • [41] Investigation of 3D microscopy using intensity diffraction tomography
    Anastasio, Mark A.
    Huang, Yin
    Gbur, Greg
    Carney, P. Scott
    THREE-DIMENSIONAL AND MULTIDIMENSIONAL MICROSCOPY: IMAGE ACQUISITION AND PROCESSING XIII, 2006, 6090
  • [42] 3D evaluation of dental impaction using Computed Tomography
    Goncalves, S. B.
    Correia, J. H.
    Costa, A. C.
    BIODENTAL ENGINEERING II, 2014, : 107 - 110
  • [43] 3D Modeling of a Guitar Using a Computer Tomography Scan
    Dalwale, Siddique
    Özer, M. Sait
    Merchel, Sebastian
    Altinsoy, M. Ercan
    arXiv, 2023,
  • [44] 3D analysis of semiconductor structures using STEM tomography
    Yates, TJV
    Weyland, M
    Laffont, L
    Zhi, D
    Dunin-Borkowski, RE
    Midgley, PA
    MICROSCOPY OF SEMICONDUCTING MATERIALS 2003, 2003, (180): : 541 - 544
  • [45] 3D Reconstruction of Cochlea Using Optical Coherence Tomography
    Karvonen, Tuukka
    Uranishi, Yuki
    Sakamoto, Tatsunori
    Tona, Yosuke
    Okamoto, Kazuya
    Tamura, Hiroshi
    Kuroda, Tomohiro
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 5905 - 5908
  • [46] Review of Acetabular Fracture Classification Using 3D Volume-Rendered CT
    Cheekatla, S.
    West, C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [47] 3D correction of trunk deformity in patients with idiopathic scoliosis using Cheneau brace
    Rigo, M
    RESEARCH INTO SPINAL DEFORMITIES 2, 1999, 59 : 362 - 365
  • [48] Quantifying flake scar patterning on cores using 3D recording techniques
    Clarkson, C
    Vinicius, L
    Lahr, MM
    JOURNAL OF ARCHAEOLOGICAL SCIENCE, 2006, 33 (01) : 132 - 142
  • [49] Quantifying wear depth in hip prostheses using a 3D optical scanner
    Hollar, Katherine A.
    Ferguson, Daniel S.
    Everingham, John B.
    Helms, Jillian L.
    Warburton, Kevin J.
    Lujan, Trevor J.
    WEAR, 2018, 394 : 195 - 202
  • [50] viewshed3d: An r package for quantifying 3D visibility using terrestrial lidar data
    Lecigne, Bastien
    Eitel, Jan U. H.
    Rachlow, Janet L.
    METHODS IN ECOLOGY AND EVOLUTION, 2020, 11 (06): : 733 - 738