Influence factors and reasonable arrangement of corridor width of ±800 kV HVDC and 750 kV HVAC hybrid transmission lines

被引:2
|
作者
Zhang, Qian [1 ]
Li, Yinfei [1 ]
Li, Xuebao [1 ]
Lu, Tiebing [1 ]
机构
[1] North China Elect Power Univ, State Key Lab Alternate Elect Power Syst Renewabl, Beijing 102206, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
HVDC power transmission; HVDC power convertors; power transmission lines; voltage; 750; kV; 800; fixed separation distance; electromagnetic environment; high-voltage alternating current transmission lines; high-voltage direct current transmission lines; HVAC hybrid transmission lines; HVDC transmission lines; DC line; AC line; voltage-level combination; minimum corridor width; parallel transmission lines; hybrid electric field; reasonable arrangement; ION-FLOW FIELD;
D O I
10.1049/joe.2018.8901
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
With the development of economy and the increased demand of power energy, it is unavoidable that high-voltage direct current (HVDC) and high-voltage alternating current (HVAC) transmission lines are in the same corridor. In order to minimise the land resource and meet the requirements of the electromagnetic environment, it is necessary to accurately predict the hybrid electric field under the hybrid transmission lines. The +/- 800kV HVDC and 750kV HVAC parallel transmission lines of parallel erection are chosen to be analysed. The corridor width with a different separation distance is calculated, and the minimum corridor width under this voltage-level combination is obtained according to the control value of the hybrid electric field recommended at home and abroad in a non-residential area. Increasing the height of DC or AC lines can reduce the corridor width. At a fixed separation distance, the minimum height of the AC line can be obtained when the height of the DC line is set at a certain value. Meanwhile the change of the corridor width is analysed with different heights of DC lines and AC lines. Based on the above analysis, the reasonable arrangement is made.
引用
收藏
页码:2539 / 2543
页数:5
相关论文
共 13 条
  • [1] Analysis of coupling characteristics of hybrid electric field in the 750kV HVAC and ± 800kV HVDC parallel transmission lines
    Sun, Qiang
    Wu, Jian
    Lv, Haiping
    Han, Wen
    Wang, Lv
    Min, Jianwen
    Zhang, Qian
    Li, Yinfei
    Li, Xuebao
    [J]. 2017 IEEE 5TH INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (EMC-BEIJING), 2017,
  • [2] Analysis of ionized field under ±800kV HVDC transmission lines
    Lu, Tiebing
    Zhao, Jie
    Cui, Xiang
    Feng, Han
    [J]. 2006 17TH INTERNATIONAL ZURICH SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY, VOLS 1 AND 2, 2006, : 416 - +
  • [3] Calculation of the ground hybrid electric field of ±800kV EHV DC and 750kV UHV AC parallel transmission lines
    Yang Zhaoguang
    Wen Dingjun
    Gao Lichao
    Bao Yanyan
    Chen Bodong
    [J]. 2017 3RD INTERNATIONAL CONFERENCE ON ENERGY, ENVIRONMENT AND MATERIALS SCIENCE (EEMS 2017), 2017, 94
  • [4] The Ionized Fields and the Ion Current on a Human Model Under ±800-kV HVDC Transmission Lines
    Li, Xuebao
    Cui, Xiang
    Zhen, Yongzan
    Lu, Tiebing
    Luo, Zhaonan
    Fang, Chao
    Zhou, Xiangxian
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2012, 27 (04) : 2141 - 2149
  • [5] Back-flashover resistance level of ±800 kV/500 kV AC-DC hybrid transmission lines
    School of Electrical Engineering, Southwest Jiaotong University, Chengdu
    610031, China
    不详
    610000, China
    不详
    200122, China
    [J]. Dianli Zidonghua Shebei Electr. Power Autom. Equip., 10 (101-106 and 114):
  • [6] Influence of AC transmission lines on parallelly erected ±500 kV HVDC double circuit transmission lines and suppression measure
    China Electric Power Research Institute, Beijing 100192, China
    不详
    [J]. Dianli Xitong Baohu yu Kongzhi, 1674, 19 (70-75):
  • [7] Measurement of Corona Characteristics and Electromagnetic Environment of ±800 kV HVDC Transmission Lines under High Altitude Condition
    Zhang, Zheng
    Zeng, Rong
    Yu, Zhanqing
    [J]. PIERS 2009 MOSCOW VOLS I AND II, PROCEEDINGS, 2009, : 61 - 65
  • [8] Study on Electromagnetic Influence of 750kV AC Transmission Lines on Multiple Buried Pipelines
    Sun Haifeng
    Wang Pei
    Chang Haojing
    Ai Xiancang
    E Tianlong
    Su Bonian
    Zhu Rongrong
    Li Zhihong
    Wang Chunfeng
    [J]. 2016 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (APEMC), 2016, : 31 - 34
  • [9] Statistical Analysis of Long-Term Measured Electric Field of the Operating ±800 kV HVDC Bipolar Transmission Lines
    Xie, Huichun
    Zhang, Jiangong
    Yao, Weifang
    Zhang, Yemao
    Xu, Jilai
    Gan, Zheyuan
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2024, 39 (02) : 1040 - 1050
  • [10] Analysis of the three-dimensional hybrid electric fields and the related electrostatic induction effects of 800 kV DC and 500 kV AC parallel transmission lines considering environmental factors
    Ma, Aiqing
    Chen, Jian
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2018, 163 : 638 - 646